(Fill out for I/O unit only) EX500 EX126 EX250 SI unit COM DeviceNet CC-LINK PROFIBUS-DP AS-i DeviceNet PROFIBUS-DP CC-LINK Remote I/O CC-LINK CANopen Nil +COM Nil PNP (+) or without SI unit/input block COM N NPN () N Note) Leave the box blank for the SI unit COM without SI unit (SD0).
Note 7) When Without SI unit (SD0, SD60) is specified, With DIN rail (D) cannot be selected. Note 8) When changing the specifications of the EX600 from no DIN rail to DIN rail mounting, please consult SMC. Note 9) DIN rail is not attached (but shipped together) on the manifold in case of the EX600 with DIN rail. Refer to back page 597 for mounting method.
Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: None, A,B Port Thread Type: Rc (or None), Mounting Option: Mounting Screw, Round Head Combination Screw, Wiring Specification: W1
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: 02 (Side, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: 02 (Side, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD6N (Serial Kit for PROFIBUS DP), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 2 Stations, A, B Port: 02 (Side, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: 02 (Side, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS DP, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 2 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EtherNet/IPâ„¢, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EtherNet/IPâ„¢, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 1 Station, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 2 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 5 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 9 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 6 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 6 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: 7 Input Blocks, Type of Input Block: M12, 4 Inputs, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 12 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 10 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: -, Stations: 3 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: Serial Kit for PROFIBUS-DP, End Plate: -, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -