Refer to Trouble No.13 Buttons do not work. The body of the Refer to Trouble No.14 pressure switch has become loose. There is noise. Refer to Trouble No.15 Refer to Trouble No.16 -56No.PS-OMS0007-H Troubleshooting list Problem No.
Open/ Close success: default output DO[101] Open / Close failure: default output DO[102] workpiece drop detection: default output DO[103] * Digital output port can be selected within DO[101] to DO[112] * you select the same digital output port for different status signals, a warning message will be displayed. 2. Test run The manual operation of the air gripper unit can be checked.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
Item Reference page 16-2-30 Output type Example of internal circuit and wiring 16-2-31 Auto shift function, Anti-chattering function 16-2-32 Measures to be taken when error occurs 16-2-33 16-2-38 15 Series ZSE60F/ISE60 High Precision, Digital Pressure Switch for General Fluids Dimensions Bracket A A 30 20 ZSE ISE 20 PSE 45 Z I SE3 55 4.5 11.5 40 15 PS 4.5 Z I SE1 2 Courtesy of Steven Engineering
Refer to each construction drawing on the fittings and tubing material. (2) Do not expose the product to direct sunlight for an extended period of time. (3) Do not use in a place subject to heavy vibration and/or shock. (4) Do not mount the product in locations where it is exposed to radiant heat. (5) Do not use the ordinary fittings and tubing in locations where static electricity would
Do not attempt to insert or pull the pressure sensor or its connector when the power is on. 3. A cable with a right-angled connector is also available. The right-angled connector faces down (toward the piping). Do not attempt to rotate the connector, as it is not rotatable. 16-2-52 9 Series ISE70/75/75H Specific Product Precautions 1 Be sure to read before handling.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with same. 2. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. Confirm the specifications for each series. 4. A protective cover, etc., should be used to shield valves from direct sunlight. 5.
Fig. 2 Center of gravity of the load mounted to the rod end Do not scratch or dent the sliding parts of the piston rod. Damage to the seals may lead to air leakage and locking failure. Do not apply loads with impact, strong vibration or rotational force while the lock mechanism is activated.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Unused bit is fixed to 0. 1: These alarms do not occur on the product of the cooling method -W. 2: These alarms do not occur on the product of the power specification '-20'. 3: These alarms do not occur on the product of the cooling method -A. 4.10 Register Map HRSH Series 4-20 HRX-OM-Q033 Chapter 4 MODBUS communication function 4.10.7 Circulating fluid set temperature The circulating fluid
Unused bit is fixed to 0. 1: These alarms do not occur on the product of the cooling method -W. 2: These alarms do not occur on the product of the cooling method -A. 3: These alarms do not occur on HRS200 series. 4.10 Register Map HRS100/150 Series 4-20 HRX-OM-S010 Chapter 4 MODBUS communication function 4.10.7 Circulating fluid set temperature The circulating fluid set temperature can be
Do not use the valves in an atmosphere having corrosive gases, chemicals, salt water, water, steam, or where there is direct contact with any of these. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.
Do not touch the inside of the driver and its peripheral 16. Do not install the product in an environment under the devices. It may cause an electric shock or damage to the driver. effect of vibrations and impacts. It will cause failure or malfunction. 2. Do not perform the operation or setting of the product 17. When a surge generating load such as a relay or solewith wet hands.
Communication example Slave Address : No.1 Read 16 pieces data from register 0030h.
Do not use in environments where there is a danger of corrosion. Maintenance Caution 1. Drain flushing Remove drainage from air filters regularly. (Refer to specifications.) Air Supply Warning 1. Use clean air. Do not use compressed air that includes chemicals, synthetic oils containing organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction.
Nylon tube Within 0.1mm Soft nylon tube Within 0.1mm Polyurethane tube Within+0.15mm, Within -0.2mm Do not use tube which do not meet these outside diameter tolerances.
Refer to pages 16-143 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. C (COM) A (N.O.) Color of lead wire Black Symbol Contact C Common B (N.C.) A White Normally Open B Red Normally Closed Mounting & Wiring ZSE ISE IFW50--01 to 04/11 to 14/21 to 24 Caution PSE 1.
Stainless Steel Cylinder Series CJ5-S 10, 16 How to Order Bore size 10 16 10 mm 16 mm Mounting style Basic style Axial foot style Rod side flange style Double clevis style B L F D Cylinder stroke (mm) Refer to Standard Stroke on page 835. CJ5 L 16 S R 60 CDJ5 L 16 S R 60 H7BAL With auto switch With auto switch (Built-in magnet) Made to Order Refer to page 835 for details.