SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-40-07-01N"

How to Order With bumper Series RBQC Basic type Series RBQ C 20 07 RBQ RBQC C Replacement part no.

I l 50i 70 , iiFl.r* 0 q . . , . 50 6o ' 3 0 3o , , , . 3 0 , : LXPB5SA 40 40 '" .,1 i Slide Screw \ I i LXPB5SB 2D 2A LXSH2BC 100 50 220 High rigidity linear guide Ball LXSH2BD 100 50 90 Screw LXSH5BC 1 0 0 50 1 6 0 LXSH5BD 1 0 0 50 70 LXSH2SA 90 40 60 Slide LXSH2SB 45 20 30 Screw LXSHSSA 60 20 40 LXSH5SB 30 1 0 20 , \ | '-t 'oo"ot| I PLc I ll'i;!:-,?

Flow Rate Characteristics ZU07LA 100 80 100 50 60 50 Vacuum pressure Vacuum pressure Air consumption [L/min(ANR)] Suction flow rate [L/min(ANR)] Air consumption [L/min(ANR)] Suction flow rate [L/min(ANR)] 50 80 80 40 40 Vacuum pressure [kPa] Vacuum pressure [kPa] Air consumption Vacuum pressure [kPa] Vacuum pressure [kPa] 60 Vacuum pressure Vacuum pressure 40 60 60 30 30 Air consumption

Construction/ Principal Parts Material Operating Fluid and Ambient Temperature Operating fluid temperature (C) (3) Vacuum Ambient temperature (C) Temperature conditions Water (Standard) Air (Standard) Oil (Standard) (V, M) Maximum Minimum 40 1 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.

Mixed Mounting of VK300 and Manifold Base of Series VK3000 Type VV5K3-20 Type VV5K3-40 1. In the case of VV5K3-20/40 When installing the 3 port valve on the manifold base, plug the R port at the corresponding mark side with the rubber plug (VK3000-8-1) as shown in the figures on the right. Plug Plug 2.

Mixed Mounting of VK300 and Manifold Base of VK3000 Series Type VV5K3-20 Type VV5K3-40 1. In the case of VV5K3-20/40 When installing the 3 port valve on the manifold base, plug the R port at the corresponding mark side with the rubber plug (VK3000-8-1) as shown in the figures on the right. Plug Plug 2. Other manifold 3 port valve can be mounted without any work.

Series ANA1 Page 5-10-8 40 dB (A) 30 m High noise reduction type Series ANB1 has a larger effective area with the same port size as Series ANA1.

40 40 40 10 5 27 27 27 27 Suction flow rate Vacuum pressure 13 13 13 13 0 0 0 4 8 12 14 0 0.1 0.2 0.3 0.4 0.5 0.6 0 5 10 15 20 25 0 0.1 0.2 0.3 0.4 0.5 0.6 Suction flow rate N (l/min(ANR)) Supply pressure (MPa) Supply pressure (MPa) Suction flow rate N (l/min(ANR)) How to Read Flow Characteristics Graph Flow characteristics are expressed in ejector vacuum pressure and suction flow.

For double solenoid For 3 position type: For 4 position type SX100-40-4DNegative common specifications Electric circuit diagram (With positive common and light/surge voltage suppressor) For single solenoid: SX100-41-4SFor double solenoid For 3 position type: For 4 position type SX100-41-4D[SOL.b] () Coil How to Order Lead wire length 2000 mm 10-SZ3160-5MO-M5 SX100-40-4S-20 COM (

S. l AR2001 2501 3001 : Max.3.5t :-t-tt ., AR4001 : Max.5.0t ~ I II; a -tp ort cenler (fJ ~ ~c=Pr r-IN j~ OUT f= 0 .bj=J ~ A * N P Q Bracket mounting dimensions Model Port size A B C 0 E F G H J K L M AR2001 1/8 1/4 40 95 17 40 35 30 34 44 5.4 15.4 55 2.3 33.5 25 8 33 AR2501 1/4 3/8 53 102.5 25 48 32 30 34 44 5.4 15.4 55 2.3 33.5 25 843 42.5 32.5

(For details, refer to "Specific Product Precautions 1" on Page 11.) 26.5 Bushing assembly 2.7 Note) For dimensions of the cable connector, refer to single unit on page 6. 7 Compact Electro-pneumatic Regulator Series ITV0 Dimensions Manifolds 20 40 20 40 4-M3 x 0.5 thread depth 3 Mounting hole 11 11 L2 Port position L1 25 No. 9.5 9.5 z x c 1 3 5 ITV00 EXH SUP OUT ITV009 PWR PWR PWR PWR ATM

ERR ERR ERR ERR Note) Stations are counted starting from the D side. 50 56 D side U side 1 2 . stations 50 9 3 (8) 6.5 6.5 Dimensions in inch are noted in parentheses. 1 1 82 89.5 SUP, VAC port 3 3 (6, 1/4") 40 40 EXH, ATM port 25 25 (6, 1/4") 2 2 2 5 5 OUT port (4, 5/32") Breathing hole Note) 3.7 (M3 x 0.5) Note) For dimensions of the cable connector, refer to single unit on page 6.

66 33 40 66 30 38 63 51 67 4 2.5 1.8 1.6 d 8 5 KQB2 Applicable tubing 4 3 2.3 2.6 H1 H2 KS KX 6 4 3.3 6 10 5.8 M A L KM 14 8 6 14 6.6 5.3 17 Connection thread 17 KF 17 25 10 7.5 6.8 30 M 22 27.1 17 7.6 17 25 H/DL L/LL 10 8 7.3 35 22 27.1 KC 17 26.6 12 9 8 45 22 28.7 17 8.5 KK 17 26.6 12 10 9 57 KK130 22 28.7 28 29.9 16 13 22 9.3 12 101 22 DM Reference dimensions after installation of R

(-Q) (S) 42 (-Q) VV5K3-40 (-Q) (S) 41 (-Q) (S) 42 (-Q) VV3K3-20 (-Q) 21 (-Q) VV5K3-20 (-Q) 21 (-Q) Manifold base Manifold base Caution Mounting Screw Tightening Torques M3: 0.6 Nm Body ported VK300-41-1A Base mounted VK300-41-2A Manifold gasket and screw assembly Note1) Mounting direction is fixed, do not mount on opposite side.

(S) 42 VV5K3-40 (S) 41 (S) 42 Manifold base Manifold base Caution Mounting Screw Tightening Torques M3: 0.6 Nm Body ported VK300-41-1A Base mounted VK300-41-2A Manifold gasket and screw assembly Note 1) Mounting direction is fixed, do not mount on opposite side.

Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series Average speed (mm/s) 800 700 600 500 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which

VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 Rated voltage 100VAC 200VAC 240VAC 6VDC 12VDC 24VDC 48VDC Rating symbol A1 A2 A3 LW06 LW2 LD4 LD8 DIN terminal Circuit diagram for connector with light The bushing may be damaged if the tightening torque of 0.8Nm is exceeded.

30 From the flow-rate characteristics of the vacuum generator (Chart 1), calculate the suction flow (Q1) of the vacuum generator from the required vacuum pressure. 20 10 e 00 10 20 30 40 50 60 70 80 90 100 110 Vacuum pressure 50 kPa (qwe) = Suction flow (Q1) 31 l/min (ANR).

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT Type 42 Type S42 1 (P) 3 (R) (Valve leakage: 0.03 cm3/s He or less) Can be used in vacuum/release circuits VP VG Universal porting Type 40 VP N.C.

DXT170-176-2-01 DXT170-176-2-02 100V 200V 100 VAC 200 VAC DXT170-176-2-03 110V 110 VAC DXT170-176-2-04 220V 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240V 6VD 12VD 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC circuit DC circuit NL: Neon bulb R: Resister D: Protective diode LED: Light emitting diode R: Resistor 4