Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.

Panel mount adapter ZS-26-B With set screw M3 x 8L (2 pcs.) and waterproof seal Panel mount adapter + Front protective cover ZS-26-C With set screw M3 x 8L (2 pcs.) and waterproof seal Front protective cover ZS-26-01 48 conversion adapter ZS-26-D It is an adapter for attaching PSE200A series in the panel cut size of PSE100 series. -8No.PS-OMW0005-C Summary of Product parts Names of individual

A B 28 SFD200-02 103.5 SMC 42 24 19 96.5 36 114.5 324 SFD Series Made to Order Specifications 1 Please contact SMC for detailed specifications, delivery and prices.

1) Remove the dust cover. 2) Supply air pressure of 0.2 MPa or more to the unlocking port, and set the lock ring to the perpendicular position. 3) Screw the unlocking bolt which is included (hexagon socket head cap screw / M3 x 10 l) into the lock ring to hold the unlocked condition. 2.

Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.

Auto Switch Mounting Direct mount Rail mount Watchmakers screw driver Auto switch mounting screw (M3 x 0.5 x 10l) Set screw Auto switch spacer Auto switch D-A9 D-F9 Auto switch mounting nut When tightening the mounting screw, use a watchmakers screw driver with a handle about 5 to 6 mm in diameter. Tighten with a torque of 0.10 to 0.20 Nm.

4 [] key Increases the set value. 18 Alarm customizing Operation during alarm condition and threshold values can be changed depending on the alarm type. 19 Communication This function is used for contact input/output or serial communication. !5 [PUMP] key Press the [MENU] and [RUN/STOP] keys simultaneously.

Air Flow Max. flow line Pressure drop (MPa) Max. air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) Model Selection Select the model in accordance with the following procedure taking the inlet pressure and max. air flow into consideration. (Example) Inlet pressure: 0.6 MPa Max. air flow capacity: 5 m3/min (ANR) 1.

Max. air flow rate (m3/min (ANR)) JIS Symbol P . 14-20-55 Inlet pressure (MPa) Caution Be sure to read before handling.

9, @0, @1, @2 and @4 from the table above DSeal kits are sets consisting of items 19, 20, 21, 22 and 24 and can be ordered using the seal kit number for each cylinder bore size.

BH BI (UU) 2-M3 x 0.5 (opposite side, same location) (For front port, use hexagon socket head set screw) Q H 2-J through JA depth of counter bore JB (opposite side, same location) 1.5 S BE CA CB BF DD D BD BG A 2.2 (0.4) Note 1) SD 16 BA 2-M3 x 0.5 depth 4 BB W 2-M3 x 0.5 (For side port, use hexagon socket head set screw) N BC Note 2) For the 180 specification, the slated line area do not

Cooled substance total volume V Cooling time h Cooling temperature difference T Facility water temperature Circulating fluid : 60 L : 15 min : 20C (20 K) (70C 50C 20C) : 20C (293.15 K) : Fluorinated fluid Density : 1.74 x 103 kg/m3 Example of conventional measurement units (Reference) 0.06 m3 0.25 h 20C 20C Fluorinated fluid Density : 1.74 x 103 kg/m3 Specific heat C: 1.05 x 103 J/(kgK)

Valve manifold Accessories Side D NOTE (SI unit side) Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.

(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED and switch LED display to indicate the status of the SI unit. 2 Switches for setting of node address and operating mode. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.

Screw torque (Nm) depth (mm) MHZJ2-10 M3 x 0.5 0.9 6 MHZJ2-16 M4x0.7 1.6 4.5 MHZJ2-20 M5 x 0.8 3.3 8 MHZJ2-25 M6x1 5.9 10 Max. tightening torque (Nm) Maximum screw-in Model No. Screw depth (mm) MHZJ2-10 M3 x 0.5 0.69 5 MHZJ2-16 M4x0.7 2.1 8 MHZJ2-20 M5 x 0.8 4.3 10 MHZJ2-25 M6x1 7.3 12 Max. tightening Model No.

Replacement part/grease pack part no. : MH-G04 (30 g) 706 MHY2 Series 180 Angular Type Air Gripper Cam Type Dimensions MHY2-10D Pin hole positioning 30 9 9 2 x M3 x 0.5 thread depth 4 4 (Thread for mounting attachment) 4 x M3 x 0.5 through (Mounting thread) 3H9+ 0.025 0 depth 3 6 0.005 0.025 4 4 x M3 x 0.5 thread depth 6 3 6 (Mounting thread) 2 x 3.4 through 2 x M3 x 0.5 depth 6 12 (Mounting

Bracket B Bracket A Bracket D Mounting screw M4 x 5L Mounting screw M3 x 5L The tightening torque for bracket mounting screw should be 0.5 to 0.7 Nm for M3 and 1.4 to 1.6 Nm for M4. Set Pressure Range and Rated Pressure Range Caution Set the pressure within the rated pressure range. The set pressure range is the range of pressure that is possible in setting.

Accessory: Cross Recessed Round Head Screw for Mounting (Zinc chromated) Model Size (Nominal x Length) Piece Metric size Inch size TMH-01J TMH-03J TMH-07J TMH-07 TMH-09 TMH-23J TMH-04J TMH-06J TMH-06 TMH-08 TMH-10 TMH-12 M3 x 15 M3 x 20 1 M4 x 25 M4 x 35 TMH-13 Series Holder mounting Select the applicable holder/TMH for each speed controller from the below table.