SMC Corporation of America
Elite Part Number Search
Search Results "RZQF50-150-20"

C4 C6 C4 C6 Stations L1 L2 L3 L4 3 4 5 6 7 8 9 10 2 123 135.5 125 102 16.5 148 148 160.5 150 173 185.5 175 198 210.5 200 112.5 91.5 15.5 137.5 137.5 123 12.5 162.5 144 14.5 187.5 165 16.5 133.5 13.5 154.5 15.5 175.5 17.5 112.5 17.5 Stations SS5Y3-45GUBC4 C6 2 3 4 5 6 7 8 9 10 Stations L1 L2 L3 L4 135.5 125 108 13.5 148 160.5 150 129 15.5 173 185.5 175 150 17.5 185.5 175 198 210.5 200 223

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure

Bearing Style: Slide Bearing, Bore Size: 100mm, Port Thread: Rc, Stroke: 150mm, Table Turn Position: 180° Rotation, No Detector Arms, No Switch Bracket, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Table Auto Switch: -, Table Switch Lead Wire or Prewired Connector: -, Table Switch Number: -

Bearing Style: Ball Bushing Bearing, Bore Size: 100mm, Port Thread: Rc, Stroke: 150mm, Table Turn Position: 180° Rotation, No Detector Arms, No Switch Bracket, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Table Auto Switch: -, Table Switch Lead Wire or Prewired Connector: -, Table Switch Number: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: No, Valves: No, Specification: Copper-free and fluorine-free specification,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Port thread

3 position cylinder series RZQ provides intermediate stop mechanism. 2 intermediate strokes are possible with only a small extension in total length. First stage stroke can be specified without changing the overall length. High accuracy is achieved by an intermediate stop method of pressing metallic components against each other. A tube rod with a large bore which is 70% the piston diameter

Type 1: Floating Joints, Cylinder Used: Hydraulic Cylinders, Connection Type Cylinder Side: Tapped, Connecting Thread Nominal M(mm): M20 to M26, Connecting Thread Nominal p(mm): 1 to 1.75, Connection Type, Workpiece Side: Threaded, Main Body Material: [Steel] Carbon steel, Metallic Head: Not Provided, Stud Material: [Steel] Chrome molybdenum steel, Allowable Misalignment U(mm): 2, Allowable

Type 1: Floating Joints, Cylinder Used: Hydraulic Cylinders, Connection Type Cylinder Side: Tapped, Connecting Thread Nominal M(mm): M20 to M26, Connecting Thread Nominal p(mm): 1 to 1.75, Connection Type, Workpiece Side: Thru-Hole, Main Body Material: [Steel] Carbon steel, Metallic Head: Flange Hardware, Stud Material: [Steel] Chrome molybdenum steel, Allowable Misalignment U(mm): 2, Allowable

Type 1: Floating Joints, Cylinder Used: Hydraulic Cylinders, Connection Type Cylinder Side: Tapped, Connecting Thread Nominal M(mm): M20 to M26, Connecting Thread Nominal p(mm): 1 to 1.75, Connection Type, Workpiece Side: Thru-Hole, Main Body Material: [Steel] Carbon steel, Metallic Head: Foot Hardware, Stud Material: [Steel] Chrome molybdenum steel, Allowable Misalignment U(mm): 2, Allowable

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Port thread

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: No, Valves: No, Specification: Copper-free and fluorine-free specification,

Mounting: Foot, Bore Size: 63mm, Thread: NPT Thread, Full Stroke: 150mm, First Stroke: 20mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -