Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.

77 91 Side support B MY-S25B M6 x 1 35 77 8 50 91 A set of side supports consists of a left support and a right support.

12.0 0.5 Axis 3 Absolute 50 100.00 1000 1000 0 0 30 100 6.0 12.0 0.5 Axis 1 Relative 500 800.00 1000 1000 50 50 35 100 0 0 10.0 1 Axis 2 Relative 500 900.00 1000 1000 50 50 35 100 0 0 10.0 Axis 3 Relative 500 900.00 1000 1000 50 50 35 100 0 0 10.0 Step Data details Description Input range Explanation Step No. 0 to 2047 Number of step data. 3 lines (4 lines partially) of data per step.

4.0 10.0 Position loop gain 120 84 120 84 Speed loop gain 3000 4000 3000 4000 Speed integral compensation 20 50 20 50 7 16 8.

LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds 0.5 to 5.0 the set value.

Indicator light Output 1 and 2: Orange Power supply voltage 12 to 24 VDC 10% Current consumption 50 mA max. Enclosure IP65 Operating temperature range 0 to 50 oC (No freezing and condensation) Environment Operating humidity range Operation, Storage: 35 to 85%R.H. (No condensation) Withstand voltage 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.

50 50.00 1000 1000 0 0 0 0.5 2 Axis 3 Absolute 50 50.00 1000 1000 0 0 0 0.5 Axis 4 Absolute 50 50.00 1000 1000 0 0 0 0.5 Movement (ex.)

Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.

[i_o ] SW/external input setting 2 [ oUt] SW output [oUt1] Output mode of OUT1 [ HYS] Hysteresis mode [1ot ] Switch operation of OUT1 [ 1_P] Normal output 50% of maximums rated flow range [ 250] 250 L/min (500 L type) [ 500] 500 L/min (1000 L type) [1000] 1000 L/min (2000 L type) [P_1 ] Set value of OUT1 5% of maximums rated flow range [ 25] 25 L/min (500 L type) [ 50] 50 L/min (1000 L type

10.00 1000 1000 0 0 0 0.5 2 INC 50 10.00 1000 1000 0 0 0 0.5 2 3 INC 50 10.00 1000 1000 0 0 0 0.5 4 INC 50 10.00 1000 1000 0 0 0 0.5 57 No.SFOD-OMT0009CN-B () ... ...

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact SMC regarding other voltages.

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact P/A regarding other voltages.

Specification Table Battery-less absolute encoder type (Step motor 24 VDC) Model EQFS25 EQFS32 EQFS40 Stroke[mm] Note1) 50 to 800 50 to 1000 150 to 1200 Horizontal 15 26 40 40 39.5 50 68 68 26 60 75 80 Work load [kg] Note.2) Vertical 2 6 12.5 15 4 10 16 20 4.5 4.5 25 40 to 400 20 to 1200 12 to 850 6 to 450 3 to 225 24 to 1100 16 to 750 8 to 450 4 to 125 30 to 1200 20 to 1000 10 to 500 5 to

Setup communication cable part number (with A-miniB type USB cable): JX-CT-E PC 120.3 120.3 mm mm Electric actuator Setup communication cable 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 USB cable A-miniB type PC is prepared by the user. ..

CQ2 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Built-in Magnet Cylinder Model Double acting Action D 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 RQ If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch. (Example) CDQSL25-30D 25 For Manufacture of Intermediate Strokes, refer to page 552.

. / guideline switching stroke 75% 0.4 Example) When a cylinder whose stroke is 50 mm is operated at 100 mm/sec, the formula is: 50 / 100 = 0.5. As the value is greater than 0.4, deceleration control is possible. When a cylinder whose stroke is 50 mm is operated at 200 mm/sec, the formula is: 50 / 200 = 0.25.

, Tie-rod, cushion valve, and tie-rod 40 XC7 * Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 nut made of stainless steel 25, 50, 75, 100, 125, 150, 175, 200, 250, XC8 XC9 XC14 XC15 XC22 Adjustable stroke/Extension adjustment 1 50, 63 300, 350, 400, 450, 500, 600 2 Adjustable stroke/Retraction adjustment 25, 50, 75, 100, 125, 150, 175, 200, 250, Change of trunnion

Standard Strokes Bore size [mm] Standard stroke [mm] *1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 *1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.

Refer to the cylinder catalog for details. 10 Optimum Actuation Size Chart of Air Cylinder For JSY3000, A, B port: 8 Horizontal Vertical (Upward) Average speed [mm/s] 0 100 200 300 400 500 600 700 800 32 CM2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 300 mm 40 50 63 CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke