40 J (5) Drain guide 1/4 AFM30/40 Float type auto-drain (N.C.) (4) Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right Left AFM20 to 40 N (1) Drain cock with barb fitting: 6 x 4 nylon tubing Float type auto-drain (N.O.) (4) W F (2) AFM30/40 D AFM30/40 Note 1) Drain guide is NPT 1/4 (applicable to AFM30 and 40), and the exhaust port for auto-drain comes
Micro Mist Separator Series AFD20/30/40 How to Order 03 BD F 30 2R AFD Option Symbol 2 6 8 C J R Description Applicable model Micro mist separator Accessory AFD20 to 40 AFD20 to 40 AFD30/40 AFD20 AFD30/40 AFD20 to 40 Metal bowl Port size F.R.L. Description With bracket Float type auto-drain (N.C.) Float type auto-drain (N.O.)
EX245-DY1 . 75 12.1. . 75 12.2. . 76 12.3. . 77 12.4. . 77 12.5. LED . 78 12.6. . 79 13. . 80 13.1. . 80 13.2. Y . 81 13.3. . 82 14. . 83 14.1. EX245-FPS1/2/3 . 83 14.2. . 85 15. . 86 15.1. EX245-FPS1/2/3 . 86 15.2. EX245-DX1 . 88 15.3. EX245-DY1 . 88 16. . 89 16.1. . 89 16.2. PROFIsafe . 99 16.3.
L dimension 31 32 33 34 35 36 37 38 39 40 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 No.
65 41 A 97 61 a 2 2 STX 34 22 " 66 42 B 98 62 b 3 3 ETX 35 23 # 67 43 C 99 63 c 4 4 EOT 36 24 $ 68 44 D 100 64 d 5 5 ENQ 37 25 % 69 45 E 101 65 e 6 6 ACK 38 26 & 70 46 F 102 66 f 7 7 BEL 39 27 ' 71 47 G 103 67 g 8 8 BS 40 28 ( 72 48 H 104 68 h 9 9 HT 41 29 ) 73 49 I 105 69 i 10 0A LF 42 2A * 74 4A J 106 6A j 11 0B VT 43 2B + 75 4B K 107 6B k 12 0C FF 44 2C , 76 4C L 108 6C l 13 0D CR 45 2D
Option Part number Remarks ZS-40-K Taptite screw for PF3W704/720 (3 x 8), 4 pcs. Bracket ZS-40-L Taptite screw for PF3W740 (3 x 8), 4 pcs. ZS-40-M Taptite screw for PF3W711 (4 x 10), 4 pcs. Lead wire with M8 connector ZS-40-A Lead wire length: 3 m : 2 brackets are necessary if using the type with flow rate adjustment valve. Bracket cannot be mounted onto the 250 L/min type.
CDQ2 series) side by side, maintain 40 mm minimum around the motor. 40 40 40 40 40 40 40 40 Air cylinder installation with an auto switch is forbidden in the shaded area. Example 2 When installing electric actuator LEY(G) or LEFEQFEQY series with an auto switch by side, leave a gap of 40 mm or more with respect to the position where the magnet passes.
5) 3 . 1 5 tBo\ 5.43 '135) 7 9 9 t203) E t 1 1 6 1 3.62 1 . 1 8 2.05 152\ o55 0.83 121\ Ml2x1 75 0.43 1 1 1 ) M26x1 5 1.57 (40) 4.S6 {126) 1.97 6.38 i162) 5.35 t136) 8.74 t222) 2.83 <72) 5.31 1135) 4 . 1 1 1206) 2.55 (65) 0.55 N4.0) 1 . 1 9 (41) 5 6 7 1215t 'Min.
5) 3 . 1 5 tBo\ 5.43 '135) 7 9 9 t203) E t 1 1 6 1 3.62 1 . 1 8 2.05 152\ o55 0.83 121\ Ml2x1 75 0.43 1 1 1 ) M26x1 5 1.57 (40) 4.S6 {126) 1.97 6.38 i162) 5.35 t136) 8.74 t222) 2.83 <72) 5.31 1135) 4 . 1 1 1206) 2.55 (65) 0.55 N4.0) 1 . 1 9 (41) 5 6 7 1215t 'Min.
Refer to Product number for standard model numbers. 20, 25, 32 1 to 349 40 to 80 5 to 345 Applicable stroke (mm) 100 25 to 345 Example Part no.: MLGPM20-39-F A 1mm spacer is installed in MLGPM20-40-F. Dimension C is 77mm. 4.
(l/min (ANR)) Air consumption 80 80 80 80 Vacuum pressure Vacuum pressure Vacuum pressure (kPa) Vacuum pressure (kPa) Vacuum pressure (kPa) Vacuum pressure (kPa) Air consumption 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 Suction flow 30 30 30 30 Suction flow 20 20 20 20 10 10 10 10 Supply pressure (MPa) Suction flow (l /min (ANR)) Supply pressure (MPa) Suction flow (l/min (ANR)) ZR1
R Port Rc (PT)1/8 40/41 Type How to Order SS3YJ7-40 -05 --01 Applicable solenoid valve SYJ714-l SYJ714M-l SYJ724-l SYJ724M-l R Port Rc (PT)1/8 R Port Rc (PT)1/4 Valve model P Port Rc (PT)1/8 01 Rc (PT)1/8 A port side P Port Rc (PT)1/4 Stations 40 Type 40 Applicable blank plate ass'y SYJ700-10-2A 2 stations 02 41 Type 41 .. ..
25, 50, 75 100, 125, 150, 175 200, 250, 300, 350 11 12 14 107 44 20 16 47 64 148 M8 35 64 6.8 19 50 7 13.5 16.5 115 49 20 16 50 78 162 M10 38 77 7.5 19 63 16.5 6.5 Bore size (mm) J K L MM ML NN OA OB OL P PA PB PW Q R S T U VA 18 27 27 40 20 6.6 11 7.5 1/8 13 38 30 104 44 118 86 106 40 M8 x 1.25 M8 x 1.25 21.5 32 32 46 22 8.6 14 9 1/4 9 47 40 130 60 146 110 130 50 M10 x 1.5 M10 x 1.5 28
CDQ2 series) side by side, maintain 40 mm minimum around the motor. 40 40 40 40 40 40 40 40 Air cylinder installation with an auto switch is forbidden in the shaded area. Example 2 When installing electric actuator LEY(G) or LEFEQFEQY series with an auto switch by side, leave a gap of 40 mm or more with respect to the position where the magnet passes.
Set screw CDRB2BW10/15 CDRBU2W10/15 CDRB2BW20 to 40 CDRBU2W20 to 40 CDRB1BW50 to 100 144
Rotary Actuators Series CDRB2/CDRBU2/CRB1 Adjustment of Auto Switch Rotation range of the output shaft with single flat (key for size 40 only) and auto switch mounting position Size: 10, 15, 20, 30, 40
Bore size (mm) 20 25 32 40 20 25 32 40 Clean room series Standard strokes (mm) Auto switches are not mounted, but rather packaged together with the cylinder for shipment. 10(Relieving type) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 11(Vacuum type) Specifications Bore size (mm) 10(Relieving type) 11(Vacuum type) 20 20 25 32 40 25 32 40 Fluid Proof pressure Maximum operating pressure Minimum
x 1.75 11 22 17 M22 x 1.5 23 37 21 4 40 204 102 18.5 80.5 116 1/2 up to 750 40 37 116 41 92 30 20 52 14 21 72 16 72.8 87.5 M12 x 1.75 11 26 17 M26 x 1.5 23 40 21 126 4 40 215 1/2 For more information about the rod end nut and accessories, please refer to page 12.
AWG AWG28 3 3m 5 5m PLC (7.5) R1.25-4(M4 ) 40 20 39 . . . 2 21 1 L PLC 1.27mm No.
Applicable base VV5Z5-40 VV5Z5-41 VV5Z5-42 Adapter plate ARBZ5000-00-P Gasket Individual SUP Spacer Assembly Round head combination screw DXT199-35-1A ( ) With spring washer Applicable base VV5Z5-40 VV5Z5-41 VV5Z5-42 Round head combination screw ( ) M3 x 47 With spring washer Gasket Individual SUP spacer Applicable base VV5Z5-40 VV5Z5-41 VV5Z5-42 Before using, refer to page 3-3-8.
Ambient temperature of servo motor Check environment so that ambient temperature is 0 to 40 . is over 40 . 2. Servo motor is overloaded. 1. Reduce load. 2. Check operation pattern. 3. Use servo motor that provides larger output. 3. Thermal sensor in encoder is faulty.