Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Single Acting/Spring Extend, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: Double Acting, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: Single Acting/Spring Extend, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A72H--Reed, AC Volt.<200, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)
Magnet: D (Built-in Magnet), Mounting: B (Through-hole), Bore Size: 50mm, Port Thread: Bore 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: T (Single Acting, Spring Extend), Rod End: Round Bar, Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: D (Double Acting), Rod End: R (Roller Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, STOPPER, AUTO-SW, ACTUATOR, RSQ/RSA MISC/SPECIALIZED, NE, 50MM RSQ DBL-ACT AUTO-SW, 2.59043 lb
A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.
Note 4) Figures in ( ) in the table W are D-A93.
-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.
Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.