SMC Corporation of America
Elite Part Number Search
Search Results "PSE543A-M5-C2"

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: TSJ 1/4, Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: Rc 1/8, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: Rc 1/8, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: Rc 1/8, Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: TSJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: Rc 1/8, Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: TSJ 1/4, Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: M3X0.5, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±1%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: Ø4 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: Ø4 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±1%F.S., Port Size: Ø4 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: M3X0.5, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±1%F.S., Port Size: M3X0.5, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 5 (24V DC; Use 24 V DC for EX180, EX510, and PC Wiring), Common Specifications: Positive Common, Connector Entry: C (Dedicated for Centralized Wiring), Light, Surge Suppressor: Z (Light/Surge Suppressor, Polar Type), Switch: None, Manual Override: D (Push-turn Locking Slotted Type), A,B Port Size: C2

Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 5 (24V DC; Use 24 V DC for EX180, EX510, and PC Wiring), Common Specifications: Positive Common, Connector Entry: C (Dedicated for Centralized Wiring), Light, Surge Suppressor: U (Light/Surge Suppressor, Non-polar Type), Switch: None, Manual Override: Non-locking Push Type, A,B Port Size: C2

Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 5 (24V DC; Use 24 V DC for EX180, EX510, and PC Wiring), Common Specifications: Positive Common, Connector Entry: C (Dedicated for Centralized Wiring), Light, Surge Suppressor: U (Light/Surge Suppressor, Non-polar Type), Switch: None, Manual Override: Non-locking Push Type, A,B Port Size: C2