DC12~24V 1. 2. 3. 4. 2 CE2 ()CEU2 CEU1 CEU5 0.1mm 2-1 CE2+CEU2 CEU2 CEU2 8 CE2+CEU1CEU5 3 CEU1CEU5 9 2-2 2-2-1 C E 2 B 40 100 Z N R 40 40mm ( mm ) H 50 50mm () 63 63mm 80 80mm J 100 100mm K (mm) 2 S 1 40 25850 25700 n n 50 25800 25650 63 25800 25650 80 25750 25600 100 25750 25600 (mm) 40 1200 950 50 1150 900 63 1150 900 80 1100 900 100 1100 850 10 2-2-2 CEU2 NPN
YES NO NO 2 YES YES NO NO YES 10 2-2 (CEU2) (AC100V,15) (24V10,0.4A) (0.3MPa0.5MPa) 3) () (CE1-R**) (CE2**) 11 2-3 40 VFS240R VFS210 AR425 8/6 AN200-02 AS4000-02 50 VFS240R VFS210 AR425 10/7.5 AN200-02 AS4000-02 63 VFS340R VFS210 AR425 12/9 AN300-03 AS4000-03 80 VFS440R VFS310 AR425 12/9 AN300-03 AS420-03 100 VFS440R VFS310 AR425 12/9 AN400-04 AS420-04 12 * 3. 3-1 () 40 50 63 80
ZB-OM00201-B (10) One-touch tube fitting (10 in one set) Body type Port size 02 2 One-touch tube fitting Straight Metric size Elbow 04 4 One-touch tube fitting 01 1/8 One-touch tube fitting Inch size 03 5/32 One-touch tube fitting * For the combination of the elbow type body and the One-touch tube fitting 4, add the suffix -N to the part number.
IRM 10 3 G Copper-free Specifications 2 Set pressure and quantity External and internal copper parts are changed to stainless steel or aluminum. 0.2MPa setting 1 to n pcs. 0.4MPa setting 1 to n pcs. 0.8MPa setting 1 to n pcs. 0 1 2 Standard part number 20 Note) Contact SMC if equipped with pressure gauge.
: (800) 258-9200-www.stevenengineering.com 30 48 19.5 31.5 21.5 30.5 13.2 13 17 21 7 10 1 4 3 8 40 73.5 41 52.8 23.7 37.7 25 35.9 15.2 15 18.5 22 9.5 12.7 5 16 1 2 57 83 Dimensions: KM12 2-4.5 mounting hole N-F applicable tubing O.D.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket
7 M A Rated flow range Calibration certificate 501 5 to 500 L/min 102 10 to 1000 L/min 202 20 to 2000 L/min Nil None A Note 8) Yes Note 8) Made to Order: Certificate in both English and Japanese Thread type Option 2 Nil Rc N NPT F G Note 1) Nil No bracket With bracket Note 7) Note 1) ISO228 compliant Port size R Symbol Port size Rated flow range 501 102 202 04 1/2 V V 06 3/4 V Note 7
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration