S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Configuration Minimum equipment and wiring requirements to get started 1 Provided Ex) 200 V AC (*1) by customer 6 5 Provided 1 by customer 7 2 3 (-) PC 1 2 4 (+) 8 C D 11 21 9 U 2 Electric Actuators Ex) LEF V W Provided by customer 3 10 (*1) Refer to LECSB Operation Manual, Chapter 3 if the power supply voltage is 100VAC. 1 Driver LECSB*-S* 2 Motor cable LE-CSM-*** 3 Encoder cable LE-CSE-
100 200 300 400 Symbol Nominal filtration accuracy (m) Nominal filtration accuracy (m) 5 10 20 Industrial Filters Replacement Procedure Actuators Modular F.R.L.
load F [N] 500 500 50 400 400 RZQ RS1H50, 63, 80 300 300 1.0 RS1H80 MI W S RS1H50 200 200 RS1H63 0.9 Operating pressure P [MPa] 0.8 100 100 CEP1 0.7 10 20 30 40 10 20 30 40 0 0 0.6 CE1 Transfer speed [m/min] = 0 Transfer speed [m/min] = 0.1 0.5 0.4 CE2 Graph (3) Graph (4) Bore size 20, 32/ = 0 Bore size 20, 32/ = 0.1 0.3 ML2B 0.2 0.1 C J G5-S 80 80 1000 2000 3000 4000 0 5000 Lateral
If the adjusting screw of the speed controller is loosened, the operating speed will increase, so the screw should be tightened completely. m Impact force MXZ12 MXZ16 1.4 2.5 V = mm/s V = mm/s 1.2 2.0 Load weight m [kg] Load weight m [kg] 1.0 1.5 0.8 0.6 1.0 V = 50 V = 50 0.4 V = 100 V = 100 V = 200 V = 200 0.5 V = 500 V = 500 0.2 0.0 0.0 60 50 40 30 20 10 0 0 5 20 15 10 25 30 35 40 45 50
300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
(Adjustable) Hysteresis Data ON: when output is ON (Red) ON: when output is ON (Red) ON: when output is ON (OUT1: Red, OUT2: Green) Indicator light Trimmer adjustment 3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees None 1 to 5 V 5% F .S.
Display LCD LED LCD with backlight 101 to 0 kPa 101 to 10 kPa Pressure setting range 200 kPa Maximum operating pressure Operation indicator light (Lights up when ON) OUT1: Green OUT2: Red Green Response frequency 200 Hz (5 ms) Hysteresis mode Variable (3 digits or more) Variable (can be set from 0) Hysteresis Fixed (3 digits) Window comparator mode Fluid Air, Non-corrosive gas Temperature
CAM FOLLOWER GUIDE SLIDER ACTUATOR, ELECTRIC ACTUATOR, A22, 3.76000 lb
CAM FOLLOWER GUIDE SLIDER ACTUATOR, ELECTRIC ACTUATOR, A22, 4.28000 lb
CAM FOLLOWER GUIDE SLIDER ACTUATOR, ELECTRIC ACTUATOR, A22, 6.77000 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
ELECTRIC ACTUATOR. CAM FOLLOWER GUIDE SLIDER ACTUATOR. 5.91000 lb. A22.
ELECTRIC ACTUATOR. CAM FOLLOWER GUIDE SLIDER ACTUATOR. 6.03000 lb. A22.
CAM FOLLOWER GUIDE SLIDER ACTUATOR, ELECTRIC ACTUATOR, A22, 5.15 lb
CAM FOLLOWER GUIDE SLIDER ACTUATOR, ELECTRIC ACTUATOR, A22, 4.3 lb
CAM FOLLOWER GUIDE SLIDER ACTUATOR, ELECTRIC ACTUATOR, A22, 4.18 lb
NPN STROKE LEARN DC CONTROLLER, ELECTRIC ACTUATOR, A02, 0.25000 lb
PNP STROKE LEARN DC CONTROLLER, ELECTRIC ACTUATOR, A02, 0.23000 lb
PNP STROKE LEARN DC CONTROLLER, ELECTRIC ACTUATOR, A02, 0.46000 lb