SMC Corporation of America
Elite Part Number Search
Search Results "JAHF80-30-200"

Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

Air consumption 200l/min ANR) 30 Air consumption 100l/min (ANR) Air consumption 50l/min (ANR) 20 20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.

Air consumption 200l/min ANR) 30 Air consumption 100l/min (ANR) Air consumption 50l/min (ANR) 20 20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.

(mm) Symbol 1 2 3 Note 2) Port size Rc 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 4 Symbol Nil: Non-locking push type N.C. 1 MPa N.C. 0.5 MPa N.O. 1 MPa C.O. 1 MPa Note) 4 Note 2) A: Non-locking push type A (projecting) 1 6A 8A 10A 1 8 1 4 3 8 5 6 Note 2) 7 Valve size 1 to 4 7 Note 2) 11 15 11 10A 3 8 B: Slotted locking

Note 1: ON/OFF 50 ms flashing Note 2: ON 200 ms single flash, OFF 1 s Note 3: ON/OFF 200 ms double flash, OFF 1 s Note 4: ON/OFF 200 ms triple flash, OFF 1 s Note 5: ON/OFF 200 ms flashing Safety Instructions Installation Setting Troubleshooting Warning General instructions on installation and maintenance Technical documentation giving detailed troubleshooting information can be found on

30 days based on JIS B 8374-1981) Max. 50C Ambient and fluid temperature Lubrication Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)

VS3135 A01-01 A01-02 A07-52 q Description Electrical entry VS3145 Solenoid cover Body 100 VAC 200 VAC Grommet A12-01 A12-02 A08-52 w e Spool/Sleeve 24 VDC A01-01-63 A01-02-63 A07-52-63 100 VAC 200 VAC Conduit terminal 24 VDC A12-01-63 A12-02-63 A08-52-63 Replacement Parts Material Part no. VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No.

Maximum operating pressure Pv (MPa) 1 5 0.3 Model Allowable load mass mv (kg) Model Cushion stroke Stroke (mm) CYV15 CYV32 CYV15 CYV32 25 30 6

Information End Lock Cylinder Series CBJ2 / 16 Cylinder stroke (mm) 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available in 1 mm increments without stroke adjustment with a spacer. For types with auto switch, refer to Minimum Strokes for Auto Switch Mounting on page 2.

Compact and Low Profile Mechanical Joint Rodless Cylinder Compact and Low Profile Mechanical Joint Rodless Cylinder 4058mm 25/37mm 16/28mm 4058mm 25/37mm 16/28mm Reduction in height by 30% over other P/A rodless cylinders Parallel arrangement of the guide and the actuating unit results in compact design.

Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.

kPa 90% -ISA3-F ISA3-G ISA3-H 1 m 1 m 1 m [sec] [sec] [sec] [mm] [mm] [mm] 3 m 3 m 3 m [sec] [sec] [sec] [mm] [mm] [mm] 5 m 5 m 5 m [sec] [sec] [sec] [mm] [mm] [mm] -18No.PS-OMR0001CN-J 2 () [()][] 1.5 F42.51 m3 m5 m GH641 m3 m5 m 200 kPa ISA3-F ISA3-G 1 m3 m5 m 1 m3 m5 m [mm] [mm] 9 0 10010 ISA3-H 1 m3 m5 m [mm] 29 0 30030 -19No.PS-OMR0001CN-J 2 ISA3-() ISO1179-1 1 2 3 4 5

300 100 200 300 400 Flow rate L/min Flow rate L/min (ANR) Flow rate L/min (ANR) SRH3100-02 SRH3110-02 SRH3100-02 0.5 0.20 0.20 0.4 Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05 0.1 0 100 200 300 400 0 2 4 6 400 100 200 300 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min SRH4000-03 SRH4010-03 SRH4000-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure MPa Outlet

Color KK130 T0604-250-X64 T0604-500-X64 200 200 475 475 52 52 120 200 5.1 9.4 Black, White D1 DM KDM KB D2 D3 W KR KA KQG2 KG KFG2 MS KKA KP LQ MQR T T IDK 463

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Valve type Port size Rated voltage Valve size 3 2 1 100 VAC 50/60 Hz Symbol Nil: Non-locking push type Orifice size (mm) Symbol Port size Rc 1 2 3 Note) 4 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz Symbol N.C. 1 MPa N.C. 0.5 MPa N.O. C.O.

Add 10 g for the conduit type, 30 g for the DIN terminal type, and 60 g for the conduit terminal type. Refer to Glossary on page 17-3-15 for details of max. operating pressure differential and max. system pressure.

V, 30 mA PNP ooen colleclor outout: l\,4ax. 30 mA :: W Lineariiy Within 11% (full sDan Hysleresis Within 0.5% (full span) Repeatability Within 10.5% (fullspan Sensitivity Wilhin 0.2% (full span) TemDerature characteristics Wilhin 10.12% (f ull span)/'C Output p.

6.5.1 Initial I/O Signal Allocation . 30 6.5.2 Signal Allocation using Setup Software . 30 6.5.3 Allocation Examples . 31 6.5.4 I/O Signal Allocation Check . 33 6.6 Positioning Mode in Setup Software .34 6.6.1 Positioning Mode . 35 6.6.2 Motor speed Configuration . 36 6.6.3 Acceleration/deceleration Time Configuration . 37 6.6.4 Movement distance Configuration and Operation . 38 6.7 Saving

Tightening torque Nm 28 to 30 36 to 38 48 to 50 48 to 50 Tightening torque Nm 7 to 9 12 to 14 22 to 24 28 to 30 Thread Rc 3/4 Rc 1 Rc 1, 1/2 Rc 2 Thread Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Supply voltage > Internal voltage drop of switch Minimum operating voltage of load 2. Apply a wrench only to the metal part of the piping when installing the flow switch onto the system piping.

40 60 Adsorbent for low dew point Symbol Port size Symbol Size Applicable standard size Power supply voltage Thread type 20 30 40 60 Symbol Description 02 04 06 1 4 1 2 3 4 Symbol Nil Type Rc Single phase 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 110 VAC (50 Hz) Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134 Heatless Air Dryer