D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 12 to 100 B A D-P3DW 80, 100 25 to 63 B Ht A Hs Hs Auto Switch Proper Mounting Position Applicable Cylinder Series: MGP (mm) Auto Switch Mounting Height (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV D-P3DW D-A9 D-A9V D-P3DW Bore size (mm) Bore size (mm) A 7.5 10.5
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal
End plate: Connected at EX600 Manifolds D side, incorporating the power supply connection. Solenoid valve manifold: An assembly of solenoid valves.
Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Circuit diagram Contact input signal 2 4 1 k 11 Run/stop signal input Contact input
(mm) Effective area Note 2) (mm2) Note 1) L M Weight (g) Model D 2 x applicable tubing 4 6 8 10 12 KQGH04-00 KQGH06-00 KQGH08-00 KQGH10-00 KQGH12-00 11 37 18 16 5.6 D D 13 38 18.5 22 13.1 M M 15 42.8 20.9 31 26.1 L 19 47 23 54 41.5 21 50.6 24.8 66 58.3 Note 1) D is maximum diameter.
D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5
Without D-sub connector D-sub connector entry With D-sub connector With robot cable Without D-sub connector D-sub connector entry With D-sub connector With robot cable Nil Robot adapter Applicable shaft diameter 8 10 11 AHC unit 14 15 20 24 25 M3 M5 Tool adapter Port MA310 1 MA320 1 MA210 Electric specifications Without D-sub connector Without D-sub connector D-sub connector entry With D-sub
AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 743 Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting ASDF-D Series RoHS Model Applicable tubing O.D.
K J F H K J (D) F H 2 x P Port size 2 x P Port size Conduit terminal: T DIN terminal: D M N E (N) (M) E C C 25 32 31.5 (44) A A G1/2 L L G1/2 OUT IN OUT IN Applications B B (D) F H (D) F H K J K J 2 x P Port size Cable 6 to 12 2 x P Port size With bracket e a g d Bracket h b i (mm) Model A B C D E F H J K Port size P N.C. 1/4, 3/8 1/2 3/4 1/1 40 52 65 70 22 29.5 36 40.5 20 26 32.5 35 30
[C] [60 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C] HRS018-A-10/HRS018-W-10 (Single-phase 100/115 VAC) 2500 2500 25C Cooling capacity [W] Cooling capacity [W] 25C 2000 2000 32C 1500 1500 32C 40C 1000 1000 40C 500 500 Ambient temperature or facility water temperature Ambient temperature or facility water temperature 0 0 [50 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C]
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R005 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
Additionally multiple components maybe added at D. (Example: Timer and Push Button combination for an automatic return or manual return.)
Additionally multiple components maybe added at D. (Example: Timer and Push Button combination for an automatic return or manual return.)
DIN rail mount type and box mount types are available. 587 PC Wiring System e-con Type Series PCW-EC Common Specifications Rated voltage 24 VDC Power supply line 2 A Rated current Communication line 0.3 A Insulation resistance 5 M or more at 100 VDC Withstand voltage 500 VAC Impact resistance 500 m/s2 Screw tightening torque (Phillips head screwdriver/flat head screwdriver) 0.4 to 0.6 Nm/
P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Details P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this P Regeneration option C terminal. D Connect the control circuit power supply.
P I S T O N R O D A I R H Y D R O TYPE P I S T O N R O D D E F L E C T I O N (REFERENCE FACTOR) P I S T O N R O D D E F L E C T I O N (REFERENCE FACTOR) For a concentrated load at the center of the housing. For a concentrated load at the center of the end plate.