S = 5.0 600 500 400 300 200 100 VDW304 S = 8.0 900 800 700 600 500 400 300 200 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 300l/min (ANR) for orifice 2.3 (VDW20) is P1 approx. 0.77MPa, for orifice 3 (VDW30) is P1 approx. 0.45MPa, for orifice 4 (VDW30) is P1 approx. 0.24MPa.

D L1 VMG KN KN 861 KN Series Nozzle for One-touch fitting/KN (mm) Model Nozzle size D Applicable fitting size d L1 A Weight (g) KN-Q06-100 KN-Q06-150 KN-Q06-200 KN-Q08-150 KN-Q08-200 KN-Q10-200 KN-Q10-250 KN-Q12-250 KN-Q12-300 5 5 5 9 9 16 16 23 23 18 18 18 20.5 20.5 22 22 24 24 35 35 35 39 39 43 43 45.5 45.5 6 6 6 8 8 10 10 12 12 1 1.5 2 1.5 2 2 2.5 2.5 3 D 10 A Connecting products with

MGP-A 25 16 25 16 50 2025 50 50 20 1 2 21 22 NBR 23 24 25 63100 26 NBR 27 NBR 28 29 A NBR 30 B NBR 31 C NBR 1625 32100 1663 80100 5 1625 32100 7 8 9 10 11 12 13 16 20100 15 16 17 18 19 3 16 1650 4 6 / (mm) (mm) 16 MGP16-A-PS 50 MGP50-A-PS 20 MGP20-A-PS 63 MGP63-A-PS 25 MGP25-A-PS 80 MGP80-A-PS 32 MGP32-A-PS 100 MGP100-A-PS 40 MGP40-A-PS

Male thread Suitable screw torque (Nm) Hexagonal width (mm) Adjustable spanner nominal (mm) 1/4 4.5 M3 M5 10/32-UNF 100 1/6 8 150 7 to 9 14 1/8 200 12 to 14 17 1/4 200 22 to 24 21 3/8 200 28 to 30 24 1/2 1Nm=10.2kgf/cm Tightening torque for lock nuts Caution qSuitable screw torque for a hexagon lock nut is shown in the table below.

5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 Load weight m0 (kg) MGF63 Load weight m0 (kg) Load

Do not apply a lateral load to the external slider. When a load is mounted directly to the cylinder, variations in the alignment of each shaft center cannot be offset, which results in the generation of a lateral load that can cause malfunction.

Applicable pad 4020W/5020W/6020W/8020W Applicable pad 3507W/4010W/5010W/6010W Applicable pad 4030W/5030W/6030W/8030W A-A A-A A-A (5) (5) (5) 14.8 8.8 6 1.5 A A A A A A 2 0.8 2 3.5 4 4 15 15 30 3 5 5 3 5 3 0.8 0.8 8.4 12.8 20.4 Note) R part has to be smooth with no corners.

Single vane type Double vane type +4 0 9 0 a a r r n n e n n g g g o o e e n i i t t 1 2 a a a 8 7 r t t 0 -5 +4 0 o o 0 0 n R R +4 0 +4 0 o 0 i 0 0 t a 9 1 t o e e R g g n n a a r r n n o o i i t t a a Chamfer Chamfer t t o o Chamfer A port B port Chamfer A port Chamfer R R A port B port B port A port B port A port B port For size 40 actuators, a parallel keyway will be used instead

Proper auto switch mounting positions (Series CE1) (mm) Bore size (mm) Auto switch model Symbol 20 32 40 50 63 12 A B A B A B A B A B A B A B A B A B 40.5 47 55 79 82 85.5 D-A7, A8 4 13 17 39 44 41.5 Contact protection box internal circuits 41 47.5 55.5 79.5 82.5 86 D-A7H, A80H, A73C, A80C, D-F7, J79, F7V, J79C 4.5 13.5 17.5 39.5 44.5 42 Choke coil OUT Brown [Red] CD-P11 38 44.5 52.5 76.5

Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min

A parallel key is used instead of chamfer for size 40. +5 0 +5 0 +4 0 = Max. = 200 +4 0 = Max. = 110 ) ) ( ( e e g g n End of rotation n a a r r n n o o End of rotation ti ti a a t t o o R R (90) Chamfer Chamfer (Start of rotation) (Start of rotation) (45) A port B port A port B port (Top view from long shaft side) Start of rotation is the position of the chamfer (key) when B port is

Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)

During Auto tuning Auto tuning failure A T 1 E R R 1 9 P V < 2 3 . 0 C # 1 A T F a i l u r e A u t o T u n i n g M O D E S h u t O f f C a n c e l : A T k e y <4> External sensor sampling cycle setting: Mode indication External Sensor Sampling Cycle. Default value: 180 sec. Setting range 10 to 999 sec.

A parallel key is used instead of chamfer for size 40. +5 0 +5 0 ( +4 0 +4 0 = Max. = 110 End of rotation ) e = Max. = 200 g ( e ) g n n a a r r n n o o i i t t a a t t o o R R End of rotation (90) Chamfer Chamfer (Start of rotation) (Start of rotation) (45) A port B port A port B port Start of rotation is the position of the chamfer (keyway) when B port is pressurized.

Potential malfunction may dV occur if a rectified AC with voltage rise (dv/dt) at zero crossing exceeds 40V /200 sec. dt = Voltage ratio Voltage rise % on zero-cross point dV t Time Always establish a connection to a ground for safety. Be sure that the ground connection is not made to dt a water pipe, gas pipe and lighting conductors.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

AD27-6-A With bowl guard AD27-6C-A AD37m-6-A AD47m-6-A Normally open (N.O.) With bowl guard AD38m-6-A AD48m-6-A Automatic (Auto drain) Manual With drain cock C2SF-2-A C3SF-2-A C4SF-2-A With level gauge C3LF-8-A C4LF-8-A With drain guide (without valve function) C2SFm-2J-A C3SFm-2J-A C4SFm-2J-A With level gauge C3LFm-8J-A C4LFm-8J-A Metal Normally closed (N.C.)

1 (P) (A) 4 (B) 2 3 position exhaust center (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 i 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) (This figure shows a closed center type.)