Auto switch model Electrical entry direction Load voltage Special function Indicator light Wiring (Output) Electrical entry Type Reed switch Solid state switch 0.5 (Nil) 3 (L) 5 (Z) Applicable load DC AC Perpendicular In-line IC circuit 5 V 12 V 100 V or less A90 A90V No Relay, PLC 24 V 2-wire A93 A93V Grommet 100 V 12 V Yes 3-wire (NPN equiv.) 3-wire (NPN) 3-wire (PNP) IC circuit A96
Lead wire length (m) 0.5 (Nil) Load voltage Indicator light Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 3 (L) 5 (Z) AC DC Perpendicular In-line IC circuit 3-wire (NPN equivalent) A96V A96 5 V Reed switch Solid state switch Yes Yes Grommet Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, PE, 63MM CQ2-Z DBL-ACT AUTO-SW, 2.77618 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, ME, 40MM CQ2-Z DBL-ACT AUTO-SW, 1.52603 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, SE, 100MM CQ2-Z DBL-ACT AUTO-SW, 6.94896 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, RE, 80MM CQ2-Z DBL-ACT AUTO-SW, 4.60765 lb
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, ME, 40MM NCQ2-Z DBL-ACT AUTO-SW, 1.25222 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, NE, 50MM NCQ2-Z DBL-ACT AUTO-SW, 2.17360 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, SE, 100MM CQ2-Z DBL-ACT AUTO-SW, 7.23116 lb
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0300 (3"), Cushion: w/o Rubber Bumper, Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0300 (3"), Cushion: w/o Rubber Bumper, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
(m) () AC 0.5( ) 1(M) 3(L) 5(Z) DC 3(NPN) M9NV M9N 3(PNP) M9PV M9P 2 12V M9BV M9B 5V12V IC 3(NPN) M9NWV M9NW 3(PNP) M9PWV P9PW 2 12V M9BWV M9BW IC 5V12V (2) PLC 24V 3(NPN) M9NAV M9NA 3(PNP) M9PAV M9PA 2 12V M9BAV M9PB (2) 2( ) P4DW IC 5V12V (2) (NPN) 5V A96V A96 IC 100V A93V A93 PLC 12V 24V 2 100V A90V A90 IC 18-2. 0.5m ) M9NW 1m M ( M9NWM D-P4DW32100 3m L (M9NWL 5m Z (M9NWZ
(P.29~32) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.
(P.20) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Note 1) For the tightening of the mounting screws (M2.5), use a precision screwdriver with a handle diameter of approximately 5 to 6 mm.