Non-Adjustable Hydraulic Series lmperial Clevis Mounting Pt\4120 -+ PRO110--+ PM225 PRO225 OS gU @ @M CR PM1525CM(S) --+ PM215OCM(S) Spring O ption al ! u Iilodel Wight (lbi.) (otaloq l{0, lltlodell trl tl P 0 R 5 T U v w x CR 6.59 ?
L D d m t d H B C l IY-G04 IY-G05 C type 10 for shaft 41.6 50.6 9.6 13.4 36.2 44.2 1.55 2.05 1.15 1.15 M14 x 1.5 M18 x 1.5 8 11 22 27 25.4 31.2 C type 14 for shaft 10 14 -0.040 -0.076 -0.050 -0.093 9-12-19 20 Simple Joint: 32 to 63 Type A Mounting Bracket 2-D T1 T2 M W V U F B E (mm) Joint and Mounting Bracket (Type A, Type B) Part No.
R/W AoUt (Setting of analogue output) U8 0 Y 0: 1 to 5 V 10 to 10 V Setting of analogue output (Voltage output type only) 1 R/W FrEE (Setting of free range mode) U8 0 Y 0: oFF (Unused) 1: on (Used) Setting of free range mode 2110 0x083E Setting range 0x0190 to 0x1068 (400 to 4200) 2 R/W F_H (Set value of free range) S16 4000 Y Set value of free range Rated value 10% to 105% SAVE (Accumulated
(page 83) 2030 0x07EE 0 R/W Cut (Zero cut-off setting) U8 1 Y Setting range 0 to 10 1.0% increments 0: oFF 1: rAC 2040 0x07F8 0 R/W inP (External input setting) U8 1 Y (Accumulated value reset) 2: rPb (Reset peak/bottom) 2100 0x0834 0 R/W AoUt (Setting of analogue output) U8 0 Y 0: 1-5 (1 to 5 V) 1: 0-10 (0 to 10 V) Setting of analogue output (Voltage output type only) 1 R/W FrEE (Analogue
M Contact input/output signal M Serial RS-485 communication M Analog communication (Refer to Options on page 118.) M DeviceNet communication (Refer to Options on page 118.) Wetted parts adopt the materials compatible for various circulating fluids. (Stainless steel, EPDM, etc.)
Note 1.5 m Cable length L Assembly part no. Note 1.5 m V100-DS15-015(N) V100-DS15-030(N) V100-DS15-050(N) V100-DS26-015(N) V100-DS26-030(N) V100-DS26-050(N) Cable 15 cores X23AWG Cable 26 cores X23AWG 3 m 3 m 5 m 5 m Note) For N, the unified thread is used. Note) For N, the unified thread is used.
) 1 W (With indicator light: 1.1) DC 2 2 1.4 (With indicator light: 1.5) 100 V 110 V [115 V] 1.6 (With indicator light: 1.7) 1.7 (With indicator light: 1.8) 3 1 3 1 Apparent power (VA) AC 2.3 (With indicator light: 2.4) 200 V 2.5 (With indicator light: 2.6) 2.7 (With indicator light: 2.8) 220 V [230 V] Surge voltage suppressor Refer to page 4-2-11.
(mm) 2 Effective area (mm2) Weight (g) D L Q Model D KJT02-00 6 10 4.9 8.8 0.9 1.7 Q Q 3.2 5.2 Q M Q L D D M M L L Male branch tee: KJY T H A Applicable tubing O.D.
Plug-in sub-plate (With terminal block) V Remove junction cover q of sub-plate where terminal block box w is mounted. Non-locking push style Bore 5 Push down on the manual override button with a small screwdriver until it stops.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
5 V, 12 V Water resistant (2-color indicator) 2-wire 12 V 3-wire (NPN equivalent) 4-wire (NPN) IC circuit IC circuit 5 V, 12 V 5 V With diagnostic output (2-color indicator) 100 V Grommet IC circuit 100 V or less B54 B64 100 V, 200 V Relay, PLC 12 V 2-wire 24 V 200 V or less C73C C80C Connector IC circuit 24 V or less B59W Grommet Diagnostic indication (2-color indicator) 1 Water
PSE202A-(M)# IO-Link/NPN open collector 1 output + NPN open collector 4 output specification When used as an IO-Link device Max. 30 V, 80 mA Residual voltage 1.5 V or less When used as a switch output device Max. 80 mA Residual voltage 1.5 V or less -18No.PS-OMW0012-C PSE203A-(M)# IO-Link/PNP open collector 1 output + PNP open collector 4 output specification Used as IO-Link device Max. 30
indication (2-color display) Relay PLC 24 V Yes 12 V 5 V, 12 V 2-wire Water resistant (2-color display) Grommet IC circuit With diagnostic output (2-color display) 4-wire (NPN) Latch type with diagnostic output (2-color display) F7LF Lead wire length symbol 0.5 m ...
Description Zinc die-casted Zinc die-casted Body Body w w Stainless steel Aluminum/HNBR Spool/Sleeve Spool valve e e Resin Resin Piston Piston r Pilot valve assembly r Pilot valve assembly Note) L M G 2 Note) L M G 2 VQ111(H) (Y) Voltage 1 to 6 VQ111(H) (Y) Voltage 1 to 6 Single Single VQ110L L M 2 VQ110L L M 2 Double (Latching) Double (Latching) Voltage 1 to 6 Voltage 1 to 6 Note) L M G
DC 2 W 3.2 W (Energy saving type) Note 4) (Inrush 3.2 W, Holding 1.0 W) DC Power consumption M plug connector Base mounted M plug connector Body ported L plug connector, M plug connector With light/surge voltage suppressor Electrical entry Note 1) Based on dynamic performance test, JIS B 8374-1981.
Series/Port Size Type of Actuation 2 position 2 position single double @ ]zNPTF w %NPTF titvF30(X) NVF3q)O 3 Dosition 3 po6ition 3 pogition closed cnter exhaust center pressue center . t : ' . " i : , : stlfm'JNfils #Nll;117.h ainnMh HlfFinlh NVF5000 NVF5000 2 pBition 2 position 3 position single double closed center M 3 position 3 posilion exhaLrst center Plessule centl %NPTF ffi^ 4il7h
Load voltage Auto switch model Lead wire length (m) Applicable load Perpendicular In-line Pre-wired connector Indicator light 0.5 (Nil) Special function Type Electrical entry Wiring (Output) DC AC 5 (Z) 1 (M) 3 (L) 3-wire (NPN) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW Solid state switch Reed switch IC circuit 5 V, 12 V 12 V 3-wire (PNP) 2-wire Relay, PLC Grommet Yes Yes
(standard model) 0.4 Proof pressure 1.0 MPa 0.3 Maximum operating pressure 0.7 MPa Set pressure range 0.1 to 0.6 MPa 0.2 Hysteresis 0.08 MPa or less 0.05 MPa Repeatability 0.1 Maximum contact capacity AC 2 VA, DC 2 W Operating voltage AC, DC 24 V or less 48 V 100 V 0 0.6 0.5 0.4 0.3 0.2 0.1 Max. operating current and range 50 mA 40 mA 20 mA Set pressure scale (MPa) Impact resistance 30 G
Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure
to 2.5 A (240 V) 9 A (100 V) to 4 A (240 V) 10 A (100 V) to 4 A (240 V) 8 A (200 V) Power consumption 440 W*1 850 W*1 900 W*2 1500 W*2 Alarm Refer to Alarm.