Do no let the gasket caught. 11) Mount the end plate U and D with the appropriate length of tension bolts for the number of stations required. (Tightening torque: 0.75 Nm.) 12) Mount the connector for all stations to the junction box B. (Refer to Fig.3 ) (Engage the recess of the connector and the protrusion of the junction box B.
(EX600-LBB1) Data[11] Port 2 type Data[12] Port 3 type Data[13] Port 4 type -126No.EX-OMZ0024 2-1.
Bore size (mm) A B A + B + 90 32, 40 50, 63 80, 100 25 40 30 45 60 160 190 175 55 6-7-10 11 Series MB1 Square Tube Type Air Cylinder: Standard Type Double Acting, Single Rod Accessory Bracket Dimensions Rod end nut (Standard equipment) Knuckle joint pin Clevis pin 30 Dd9 d 2-d D C L l m H B d Bore size (mm) Clevis Knuckle Part no. Bore size (mm) Part no.
(mm) H I J K L C D E F U A B Z M N O P S Bore size (mm) 32 M10 x 1.5 60 4.5 14 8.5 82 12 16 45 20 31.5 65 14 34 5.5 9 depth 7 Rc1/8 58.5 40 M10 x 1.5 69 5 14 8.5 84 12 16 52 22 35 67 14 40 5.5 9 depth 7 Rc1/8 66 50 M12 x 1.75 86 7 18 11 98 15 20 64 25 41 76 19 50 6.6 11 depth 8 Rc1/4 80 63 M12 x 1.75 103 7 18 11 102 15 20 77 27 47.5 80 19 60 9 14 depth 10.5 Rc1/4 93 80 M16 x 2 132 6 22 11
Bore size (mm) A B A + B + 90 32, 40 50, 63 80, 100 25 40 30 45 60 160 190 175 55 6-7-10 11 Series MB1 Square Tube Type Air Cylinder: Standard Type Double Acting, Single Rod Accessory Bracket Dimensions Rod end nut (Standard equipment) Knuckle joint pin Clevis pin 30 Dd9 d 2-d D C L l m H B d Bore size (mm) Clevis Knuckle Part no. Bore size (mm) Part no.
AKM2000-A AKM3000-A AKM4000-A AKM2000-A AC20-A, AC20A-A 40 28 11 40 11 1/8, 1/4 AC25-A AC30-A, AC30A-A AKM3000-A 53 34 14 48 13 1/8, 1/4 IN OUT B AC40-A, AC40A-ANote) AKM4000-A 1/4, 3/8 70 42 18 54 15 C Note) A pressure switch cannot be mounted on the AC40-06-A.
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5
*Refer to the table of Applicable stroke 6mm 6mm 8mm 8mm 10mm 10mm B B Cable type *Applicable stroke Standard produced upon receipt of order Without cable Nil Without cable Nil 100 100 200 200 300 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 Robotic type cable R Robotic type cable R 11-LEFS25 11-LEFS25 Standard cable S Standard cable S 11-LEFS32 11-LEFS32 Motor cable
5th letter Y U8 0x00 Refer to Figure "Line name communication data (7 seg)". 0x0974 (2420) 0x0975 (2421) 0x0976 (2422) 0x0977 (2423) (0) 6 R/W Line name 6th letter (11 SEG) Y U8 0x00 Refer to Figure "Line name communication data (11 seg)". (0) 7 R/W Line name 7th letter (11 SEG) Y U8 0x00 Refer to Figure "Line name communication data (11 seg)". (0) 8 R/W Line name 8th letter Y U8 0x00 Refer
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
SI unit output No. 0 1 2 3 4 5 6 7 8 9 SI unit output No. 0 1 2 3 4 5 6 7 A B A B B A Void A Void A A B A B B A A A SY Double Double Double Double Double SI unit SI unit Single Single Single Single Single SYJ Stations 1 2 3 4 5 Stations 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link
rib O Deep type B Bellows type List o Pad dia.
rib O Deep type B Bellows type List o Pad dia.
Refer to Fig.1) 3) Remove the junction box B (top) for all stations using a precision screwdriver. (Refer to Fig.2) (Remove the junction box B from D side.) 4) Remove all connectors mounted to the junction box B.
To adjust the cylinder speed, use a speed controller. 30 20 CXW32 10 CXWL25 CX2N25 Load mass (kg) CXW20 CX2N25-B, CXWM25 5 CXW16 4 CX2N15-B CX2N15 3 2 CX2N10-B CX2N10 CXW10 1 0.5 10 50 100 200 300 500 1000 Cylinder speed (mm/s) 462 Series CX2 Prior to Use 1. Changing from the non-auto switch specifications to the auto switch specifications 2.
To adjust the cylinder speed, use a speed controller. 30 20 CXW32 10 CXWL25 CX2N25 Load mass (kg) CXW20 CX2N25-B, CXWM25 5 CXW16 4 CX2N15-B CX2N15 3 2 CX2N10-B CX2N10 CXW10 1 0.5 10 50 100 200 300 500 1000 Cylinder speed (mm/s) 462 Series CX2 Prior to Use 1. Changing from the non-auto switch specifications to the auto switch specifications 2.
0(0) 0(0) 0.5(0) 5.5 A 6(4) 6(4) 7(5) 12 B A B 1.5(0) 1.5(0) B 0(0) 0(0) 1(0) 6 B 5(3) 5(3) 6(4) 11 A 7(5) 7(5) 8(6) 13 A B 6(4) 6(4) 7(5) 12 A 4(2) 4(2) 5(3) 10 B 3(1) 3(1) 4(2) 9 A 0.5(0) 0.5(0) 1.5(0) 6.5 Hs 22.5 25 28.5 32.5 Hs 25 27.5 31 35 Hs 60 62.5 66 70 Hs 69.5 72 75.5 79.5 Bore (mm) 20 25 32 40 4.5(2.5) 3.5(1.5) 2.5(0.5) 4.5(2.5) 3.5(1.5) 2.5(0.5) MGF 2.5(0.5) 7.5 5.5(3.5) 10.5
/Single Unit Body material Brass 2 x 3.4 Mounting hole W Y Grommet X U 300 Q F D Full wave rectifier (AC type) C R [mm] 1 E G Mounting method Model Port size P B B1 C D E F J K M 2 x P Port size B B1 VDW1 M5 20 10 42.4 15 6 11 M2.5 4 11 VDW2 M5, 1/8 22 11 51.7 20 8 13.5 M3 5 15 Mounting bracket dimensions (XD) Electrical entry M Model Port size P G U W X Y Grommet Q R VDW1 M5 4 28 11 34 17