With One-touch fitting Port size 01 1/8 02 1/4 03 3/8 04 1/2 Thread type G G thread 1
Example) AWM30-03BE-1N AWD 30 03 BE q w e r t Body size Description Symbol 30 40 20 Nil N Note 1) F Note 2) Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + H Mounting Without mounting option With bracket With set nut a Nil B Note 4) + Without auto drain Float type auto drain (N.C.)
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
Modular Adapter How to Order E210/310/410 Series AC-A AF-A AF-A E310 03 U AR-A Size AL-A Piping port size 210 310 410 Size 310 Port size Uni thread AW-A Symbol 410 210 01 02 03 04 1/8 1/4 3/8 1/2 AC-B Thread AF-A Uni thread U AF-A AR -A -B Specifications AL-A Model E210 E310 E410 AW -A -B Port size 3/8 1/4 1/4 1/4 3/8 1/2 1/8 AW Piping I.D. 10 8 8 8 10 12 6 AG Fluid Air Ambient and fluid
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) Deionized water: Electric conductivity 1 S/cm or higher (Electric resistivity 1 Mcm or lower) 2 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: CH1 20C/CH2 25C, r Circulating uid ow rate: Rated ow, t Power supply: 200 VAC 3 q Ambient temperature
Note 3) If clear water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industrial Association (JRA GL-02-1994 cooling water system circulating type make-up water).
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
(mm) 02 04 2 4 Nil -X19 With lock ring Without lock ring (10 or larger) 1 2 10 to 16 20 to 32 ZX 06 6 3 40, 50 ZR 08 8 Material 10 10 N S NBR Silicon rubber 13 13 ZM 16 16 Pad type U Urethane rubber 20 20 ZH F Fluoro rubber 25 25 U C Flat Flat with ribs GN Conductive NBR (2 to 16) 32 32 ZU GS Conductive silicon rubber (2 to 16) 40 40 D Deep 50 50 20 or large are manufactured upon receipt
AMJ 30 0003 2R ZR ZM Body size Pressure gauge position 30 3/8 None Bracket Nil ZH 40 1/2 B Option 50 3/4 ZU Drain cock Nil Metal bowl 2 ZL Thread type Port size Nylon bowl 6 Drain guide (Rc 1/4) 02 1/4 Nil Rc J ZY 03 3/8 Flow: Right Left F G R 04 1/2 N If ordering two options or more, indicate symbols numerically and alphabetically.
q Body size 20 30 40 50 60 Symbol Description w Pipe thread type Nil Metric thread (M5) Rc N Note 1) NPT F Note 2) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + e Port size Option a Mounting Nil Without mounting option B Note 3) With bracket + r Nil Polycarbonate bowl 2 Metal bowl 6 Nylon bowl 8 Metal bowl with level gauge C With bowl guard Note 6) Note 6) Note 6) Note 6) b Bowl 6C
Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 30 40 50 60 25 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N F Thread type e Rc NPT G + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 3) H Note 2) a Without mounting option With bracket
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 40 60 30 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N Note 2) F Note 3) Thread type Rc NPT G e + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 5) H Note 4) a Without mounting option
Process Pump Automatically Operated Type (Internal Switching Type) Series PA3000/5000 How to Order 1 1 PA 3 03 0 PA3000 Option Body size Nil N 3 5 Body only With silencer 3/8 standard 1/2 standard For AIR EXH: AN200-02 Port size Material of body wetted areas 03 04 06 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 1 2 ADC12 (Aluminum) SCS14 (Stainless steel) PA5000 Diaphragm material Thread
Mounting bracket Minimum order quantity Bore size [mm] Contents 20 25 32 40 Mounting nut (M5, Rc1/8, NPT1/8) 1 1 JSN-020B JSN-032B JSN-040B 1 mounting nut Rod end nut 1 NT-02 NT-03 NT-04 1 rod end nut Refer to page 10 for dimensions. 1 Can be used for M and MZ only.
Note 2) If tap water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL-02-1994 cooling water system circulating type make-up water).
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15 to 40% ethylene glycol aqueous solution: Diluted with clean water, without any additives such as antiseptics. (Refer to "Operation at low ambient temperature or low circulating uid temperature" (page 186-1) for the concentration of the ethylene glycol aqueous solution.)
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.