8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
A A A B A B P1 B B Section A-A (ejector) Section B-B (solenoid valve) Replacement parts list Parts list No. 1 2 3 4 5 6 7 8 Description Material No. Description Part No.
Model *1 Port size A B D E300-03-A 3/8 31.8 30 30 E400-04-A 1/2 31.8 36 36 Port size B *1 in model numbers indicates a pipe thread type. No indication is necessary for Rc; however, indicate N for NPT, and F for G. * Separate spacers are required for modular units.
A-phase pulse B-phase pulse 11 12 11 10 10 Count multiplier In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference. approximately 90 phase difference. Counter performs addition in and does subtraction in .
Although A, B+ and B marks are indicated on the terminal block, this can be used as either +COM or COM.
(Dallas) 12801 N. Stemmons Frwy, Ste. 815 Dallas, TX 75234 Tel: (972) 406-0082 FAX: (972) 406-9904 SMC Pneumatics Inc.
(Dallas) 12801 N. Stemmons Frwy, Ste. 815 Dallas, TX 75234 Tel: (972) 406-0082 FAX: (972) 406-9904 SMC Pneumatics Inc.
(Refer to page 40 for details) How to Order SY 53 20 01 5 1 LL 3 Bracket UL/CSA compliant 5 7 9 Series Nil: Without bracket F1: With foot bracket 53-SY5000 Thread type 53-SY7000 Nil F N T Rc Thread piping A, B port size 2-position single only 53-SY9000 G NPT Symbol Port size Applicable series Type of actuation NPTF 01 02 02 03 53-SY5000 1/8 2-position single (A) 4 2 (B) 1/4 53-SY7000 1 1/
(Allowable SW power supply range: 19.2 V to 28.8 V) Fig. a Fig. b Summary of Product elements Double Single Double Double Double Single Double Double No. 0 2 4 6 Side A No. 5 Side A 0 2 3 5 Station Station 1 2 3 4 1 2 3 4 6 No. 1 3 5 7 Side B No. 1 4 6 Side B R O I PROCESS FIELD BUS F R P Voltage drop of max.1 V B U S PWR(V) RUN DIA BF H L H L ADDRESS + EX250 Free EX250 DIA BF PWR(V) RUN
8370: JIS B 8361: JIS B 9960-1: (1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
PB B A B A B A N.C. N.O. Double acting Double acting With flow rate adjustment PA PA N.C. B A PB B A Double acting N.C. Double acting With bypass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & bypass PA PA N.C. PB B A B A Double acting N.C. Double acting 495
Replacement method Standard replacement period Refrigerating compressor 1 B 20,000 hours (6 years) Plate type heat exchanger 1 B 20,000 hours (6 years) Water regulating valve 1 B 20,000 hours (6 years) High pressure switch 1 B 20,000 hours (6 years) Low pressure switch 1 A 20,000 hours (6 years) Magnetic contactor 1 A 20,000 hours (6 years) Programmable controllers 1 A 20,000 hours (6 years
Thread type Nil R N NPT G G Port size 01 1/8 02 1/4 03 3/8 04 1/2 Made to Order (For details, refer to page 678.)
HEC-OM-S008 First edition Aug.2014 Rev1.2 May.2017 C Co om mm mu un ni ic ca at ti io on n M Ma an nu ua al l THERMO-CON Model No. HECR series Keep available whenever necessary.
Specifications Specifications Bore size (mm) 16 Fluid Air Operating pressure [MPa] 0.1 to 0.7 Ambient and fluid temperature (oC) -10 to 50 Repeatability (mm) 0.01 Maximum operating frequency (c.p.m.) 120 Lubrication Non-lube Action Double acting External gripping Force (N) 32.7 Gripping force Actual value per finger (N) Internal gripping Force (N) 43.5 Opening/closing stroke (both) (mm) 10
Not match with load specification (2-wire type) Output stays ON Display is normal > (Switch leak current x n) x Load resistance or load OFF current 4 > (Switch leak current x n) n: Number of switch connected in parallel Wiring failure (3-wire type) Check reversed connection of the switch wiring (Black/Blue). Correct wiring.
Grounded socket Earth leakage breaker E L N Earth PE Fig. 4.2-1 Power supply 4.2.2 Setting of circulating fluid temperature Press the [] and [] buttons on the operational panel to change the SV to required value.
(mm) Model Model Accessory TM-04 TM-06 TM-08 2 x 6 TM-04 TM-06 TM-08 TM-10 TM-12 4 6 8 10 12 2.6 x 8 4 TM-10 3 x 8 TM-12 Dimensions: Multi-tube Holder N x D (Pitch) N x holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.