When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Operate the piston within a range such that collision damage will not occur at the stroke end. 5. Consider a possible drop in operating pressure due to a power outage, etc. When a cylinder is used in a clamping mechanism, there is a danger of work pieces dropping if there is a decrease in clamping force due to a drop in circuit pressure caused by a power outage, etc.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
F D9 type (2) 11 Auto switch 1 NBR 12 Piston gasket 2 NBR 13 Piston seal 1 NBR 14 Rod seal 1 NBR 15 Gasket 3 Free-Mounting Cylinder with Air Cushion Series CU Dimensions 2-cushion needle 2-port 2-P through Q R E GB GA 4-NN MM D CB CA C K J JA E H A' A 2-P through KA B 4-T counterbore Width across flats L S + Stroke Z + Stroke (mm) Port size Bore size (mm) GA H J JA A B A' C CA CB D E GB
(EA)5 1 (P) 3(EB) u i 3 position pressure center 3 (EB) 2 (B) 1 (P) 4 (A) 5 (EA) 2(B) (A)4 (EA)5 1 (P) 3(EB) (Drawing shows a closed center type.)
C B Ozone resistant specifications 80 A mm For high temperature T Model IR1000 IR3000 D C B A For low temperature L 90 43 35 35 Non-grease specifications X1 148 68 66 66 Manifold (except series IR2120, IR3000) IRM 30 Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel regulator Precision Achieves flow consumption "under a litre" Setting sensitivity: 0.3%
Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to catalog on page 22.) 17 Series SYJ500 Construction c f a e b d c f a e b d N.C. N.O.
N.O. c f a e b d (A) 2 (A) 2 (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) h h 3 (R) 1 (P) 3 (R) 1 (P) g g Component parts Replacement parts Description Body Piston plate End cover Piston Spool valve assembly Spool spring No. No. 1 2 3 4 5 6 Material Aluminum die-casted Resin Aluminum die-casted Resin Stainless steel Note White White White Description Note No.
SYJA 2(A) 2(A) Standard VZA (P)1 3(R) (P)1 3(R) i VFA 2(A) 2(A) 2(A) 3(R) VFRA o For vacuum (P)1 3(R) (P)1 3(R) VPA4 SYJA X VZA 1(P) VTA For vacuum u y t r e w q VGA VPA VPA VPA3 i 2(A) 3(R) o X Component Parts No.
Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.
A y OUT 2 I N 1 SMC A t e IN OUT r q w Parts list Material Note Description No.
Application 8 7 6 5 4 3 2 Communication connector 1 9 Ground terminal Used for grounding EX500 Part Names Station number switch protective cover Set address and bus terminator by using the switches under this cover. ( Note2 ) Display Communication port D ( COM D ) Communication port C ( COM C ) Communication port B ( COM B ) Communication port A ( COM A ) Power supply connector Display the
AR20K-B to AR60K-B A-A w A 2 OUT 1 I N C SM A w w Pressure in diaphragm chamber Inlet pressure (IN) Pressure in diaphragm chamber Inlet pressure (IN) r r IN OUT IN (Inlet pressure) OUT (Outlet pressure) q q e e Figure 1 Normal Figure 2 Backflow When the inlet pressure is higher than the regulating pressure, the check valve w closes and operates as a normal regulator (Figure 1).
(P.124) Wetted Parts Material S H Wetted Parts Body Surface finish Diaphragm Seat Hastelloy C-22 Electropolish 316L SS secondary remelt Electropolish + Passivation Elgiloy is a registered trademark of Elgiloy Specialty Metals. Hastelloy is a registered trademark of Haynes International. Vespel is a registered trademark of DuPont.
14, 2 (PA, B) 4, 25, 3 (A, BEA, EB) Model 4, 2 (A/B) 1, 5, 3 (P/EA/EB) C[dm3/(sbar)] C[dm3/(sbar)] Cv Cv b b C6 SS5V1-16 C8 0.89 0.22 0.23 0.22 0.21 0.98 C8 SS5V2-16 C10 2.3 0.50 0.56 0.28 0.18 2.7 Note) Value is for manifold base with 5 stations and individually operated 2 position type.
C Rubber Bumper M Male Rod CM Rubber Bumper & Male Rod Feed Switch B Basic Model A Threaded Mounting Holes.
B 19.5 25 29.5 C 6.5 7 14.5 A 8 8 8 8 10 10 Model MGQ32 MGQ40 MGQ50 MGQ63 MGQ80 MGQ100 Detailed figure of a section Detailed figure of b section a a a b MGQ32 to 50 MGQ63 to 100 8-20-10 11 Compact Guide Cylinder Series MGQ Proper Auto Switch Mounting Position (Detection at stroke end) Minimum Stroke for Auto Switch D-Z7/Z80 D-Y5/Y6/Y7(V) D-Y7W(V) 1 pc. 2 pcs. 5 10 5 5 10 15 Auto switch D-Z7
Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a e B part f d z f1 x.Calculate the inertial moment of the attachment. Assuming the attachment material is aluminium alloy (relative density=2.7), r1= 16.4 (mm).
Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com e B part f d z f1 x.Calculate the inertial moment of the attachment.