SMC Corporation of America
Elite Part Number Search
Search Results "MKB20-10RZ-A90VL"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CVQ 32MM CYL W/VALVE, ACTUATOR, CVQ COMPACT CYLINDER W/VALVE, LC, CVQ 32MM CYL W/VALVE, 1.10231 lb

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

The MGP is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing length, thus enhancing the cylinders load bearing capacity. Conventional designed guided cylinders have a set bearing length resulting

The MGP is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing length, thus enhancing the cylinders load bearing capacity. Conventional designed guided cylinders have a set bearing length resulting

The MGP is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing length, thus enhancing the cylinders load bearing capacity. Conventional designed guided cylinders have a set bearing length resulting

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, B/BRG,ADJ STK/RETR, ACTUATOR, MGP COMPACT GUIDE CYLINDER, HC, 20MM MGP, 2.51877 lb

Therefore, it is important to secure as a danger zone a cylindrical area with the length of the clamp arm as its radius, and the stroke plus 20 mm as its height. 123 135 155 203 363 518 65 56 Head flange (including mounting bolt) 130 150 175 209 371 578 69 58 Calculation: (Example) MKG20-10RNZ Standard calculation: MKB20-10RZ Extra weight calculation: Head flange With arm ...222 g .130

MK-F020 MK-F025 MK-F032 MK-F040 MK-F050 MK-F063 Bore size (mm) 20 25 32 40 50 63 Head end flange(including mounting bolt) Centering location ring, Set pin, Bolt for cylinder body Calculation: (Example) MKG20-10RFN Standard calculation: MKB20-10R Extra weight calculation: Both ends tapped Head end flange With boss on head end With arm 250 g 6 g 133 g 2 g 100 g 491 g 2

MKB20 A 0 0.052 0 0.052 0.15 0.15 4 31 62 72.5 24.5 48 36 46.8 36 13.5 0.15 0.15 7.5 20 5 32 63 73.5 27.5 53.8 40 52 40 16 8 23 Note 1) Above figure is for D-A73, A80.

Operating range RB Model C 8 8 8 8 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 x 50l M3 x 60l M3 x 50l M3 x 60l M5 x 75l M5 x 85l M5 x 75l M5 x 85l M5 x 85l M5 x 95l M5 x 75l M5 x 85l M6 x 95l M6 x 130l M8 x 100l M8 x 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50

Operating range Cylinder model C D 8 8 8 8 Mounting bolt size M3 x 50 L M3 x 60 L M3 x 50 L M3 x 60 L M5 x 75 L M5 x 85 L M5 x 75 L M5 x 85 L M5 x 85 L M5 x 95 L M5 x 75 L M5 x 85 L M6 x 95 L M6 x 130 L M8 x 100 L M8 x 130 L 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Operating range RB Model C 8 8 8 8 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 x 50l M3 x 60l M3 x 50l M3 x 60l M5 x 75l M5 x 85l M5 x 75l M5 x 85l M5 x 85l M5 x 95l M5 x 75l M5 x 85l M6 x 95l M6 x 130l M8 x 100l M8 x 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50

Load voltage Internal voltage drop Applications None F Buffer spring (See note 3, previous page) R End lock (See note 1, previous page)* P Axial piping (see note 2, previous page) FR Buffer and end lock* FP Buffer and axial piping 24v AC DC or less 50mA D-A90L D-A90VL 0 None PLC 48v AC DC or less 40mA 20mA 100v AC DC or less D-A93L D-A93VL 24VDC 5~40mA 2.6V or less PLC Optional Shock Absorber

Load voltage Internal voltage drop Applications None F Buffer spring (See note 3, previous page) R End lock (See note 1, previous page)* P Axial piping (see note 2, previous page) FR Buffer and end lock* FP Buffer and axial piping 24v AC DC or less 50mA D-A90L D-A90VL 0 None PLC 48v AC DC or less 40mA 20mA 100v AC DC or less D-A93L D-A93VL 24VDC 5~40mA 2.6V or less PLC Optional Shock Absorber