Cross Reference Table of the Inner Sleeve (Metric size) Tubing Temperature FEP tubing/Series TH 80 or more Super PFA tubing/Series TL 120 or more Tubing O.D. Tubing material Applicable inner sleeve TUS (Soft polyurethane) TH/TIH (FEP) TL/TIL (Super PFA) Part no.
Note 3) AC adapter Model IZG10-CG 100 to 240VAC, 50/60Hz Input voltage Note 1) Output voltage Output current Ambient temperature Ambient humidity 24VDC +/-5% 0.8A max 0 to 40oC 20 to 80%Rh Applicable standard/directive CE cUL Note 1) AC cord for IZG10-CG1 is only for use in Japan (Rated voltage: 125V, Plug: JIS C8303, Inlet: IEC60320-C13). 22 Doc. no.IZ*-OMX0012-B 8.
Install the product in a location where the ambient temperature range is Connect the host to this unit with a twisted pair shield cable when applying between 10 to 35C and the relative humidity range is between 35 to 80%. No dew condensation is allowed on the unit. communication function or external sensor and alarm output function.
motor (100/200VAC) Type of Motor S2,S3 Incremental 17bit encoder (Resolution:131072 p/rev) Type of Motor S6,S7 Absolute 18bit encoder (Resolution:262144 p/rev) specification Encoder Electric Type of Motor T6,T7 [With LECSB-T/LECSS-T]Absolute 22bit encoder (Resolution: 4194304 p/rev) [With LECSC-T]Absolute 18bit encoder (Resolution:262144 p/rev) Power consumption[W] Note6) Horizontal 65 80
37.3 1.5 28 42.5 75.7 42.5 1/43/81/2 1/8 AW40-06-B 75 149.1 93.2 37.3 80 37.3 1.2 28 42.5 75.7 42.5 3/4 1/8 44.3 AW60-B 95 234.1 175.5 47.5 30 47.5 3.2 28 42.5 80.8 42.5 1 1/8 Optional Bracket mount dimensions Panel mount dimensions Model Q S T U AW20-B 30 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6 AW30-B 41 40 45.8 6.5 8 53 2.3 31.1 38.5 19 7 AW40-B 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21
Do not mount the product where it is exposed to materials such as Cooling capacity Option silicone, which may generate harmful gas. 002 200W Nil None Install the product in a location where the ambient temperature range is E With foot, 004 400W no rack bracket between 10 to 35C and the relative humidity range is between 35 to 80%.
%] Duty ratio (%) Pushing time (minute) 70 or less 100 LEPY10 LEPS10 Compact 80 70 10 100 50 5 7.4 Precaution on maintenance Caution 1.
Contents Bore size (mm) RQB20-PS RQB25-PS RQB32-PS RQB40-PS RQB50-PS 20 25 32 40 50 63 80 100 RQB20-PS RQB25-PS RQB32-PS RQB40-PS RQB50-PS RQB63-PS RQB80-PS RQB100-PS Cushion needle 12 Stainless steel Check seal 13 NBR Check gasket 14 NBR Set of left nos. !6, !7, !8. Needle gasket 15 !6 !7 !
One of countless combinations is shown below. 11/16 1/2 Number of Branches Barb Size May be #4 thru #10 Fitting Series IRM6 to 2 x 3 4 x 2 15/32 Mixed Barb Sizes available #1 thru #4 15/16 Ordering example above shows #6 barb inlet with 5 outlets three #2 branches; two #4 branches IRM 6 to 2 x 5 IRM 6 to 4 x 3 IRM 6 to 4 x 4 13 60 Y Fittings Note: Other Y sizes are available 80 60 7/16
x M6 x 1 through (Thread for mounting attachment) 34 51 716 MHW2 Series 180 Angular Type Air Gripper Rack & Pinion Type Dimensions MHW2-40D Flat finger type (Standard) 30 2 x M8 x 1.25 thread depth 15 (Mounting thread) 27.5 104.5 4 x M8 x 1.25 thread depth 16 (Mounting thread) Bottom through hole dia. 6.8 (Mounting hole) 2 x M8 x 1.25 thread depth 15 75.5 (Mounting thread) 56.5 37.5 54 80
Therefore, to use the cylinder near the upper limit of the constant holding force, be aware of the following: Select the cylinder bore size so that the load is less than 80% of the holding force. If slipping occurs when the load is over holding force, the brake shoe will be damaged, and it is possible the holding force will become smaller or the cylinder life shortened.
Therefore, to use the cylinder near the upper limit of the constant holding force, be aware of the following: Select the cylinder bore size so that the load is less than 80% of the holding force. If slipping occurs when the load is over holding force, the brake shoe will be damaged, and it is possible the holding force will become smaller or the cylinder life shortened.
Therefore, to use the cylinder near the upper limit of the constant holding force, be aware of the following: Select the cylinder bore size so that the load is less than 80% of the holding force. If slipping occurs when the load is over holding force, the brake shoe will be damaged, and it is possible the holding force will become smaller or the cylinder life shortened.
Select the cylinder bore size so that the load is less than 80% of the holding force. If the piston rod slips because the lock's holding force has been exceeded, the brake shoe could be damaged, resulting in a reduced holding force or shortened life. 1.
Select the cylinder bore size so that the load is less than 80% of the holding force. If the piston rod slips because the lock's holding force has been exceeded, the brake shoe could be damaged, resulting in a reduced holding force or shortened life. 1.
blow Clean regulator SFA, SFB1 N2 gas 296 Variations Flow rate L/min (ANR) (Inlet pressure is 0.7 MPa, at pressure drop of 0.02 MPa) Series Filtration Temperature C Pressure MPa Page Replacement of element Disc type SFA10 26 SFA20 70 P . 299 HAA HAW AT 0.01 m SFA30 140 Filtering efficiency 99.99% ( ) IDF IDU Membrane element ( ) IDF FS Cartridge type Disposable type IDFA SFB10 45 0.99 5 to 80
Rod end configuration Standard strokes Size Type Action Series 10 20 30 40 50 75 100 125 150 175 200 250 300 Reed switches: D-Z7, Z8 Solid state switches: D-Y5, Y6, Y7 Female threads Male threads 180 Single rod Double acting CQ2 200 Double rod New 180 and 200 Compact cylinder variations A wide range of 15 sizes from 12 to 200 Bore size (mm) Compact cylinder series 12 16 20 25 32 40 50 63 80
P-80 (D) This catalog is printed on recycled paper with concern for the global environment.
62 80 H M 14 8 18.5 14 42 A 17 L 54.3 47.3 49.3 60.5 54.5 17 10 24 21 22 19 22 12 34 22 Connection thread Reference dimensions of R thread after installation.