The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), INTERFACE REGULATOR, VALVE, SS5V2 MANIFOLD SV2000, 22, SS5V2 OTHER SIZE RATING, .20240 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .08800 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .08800 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MFLD BLOCK, VALVE, SS5V2 MANIFOLD SV2000, 11, SS5V2 OTHER SIZE RATING, .20240 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient & fluid temperature: -10 to 50° C, Enclosure: IP67 (based on IEC529), 2 Position Single Solenoid, 4/5 PORT SOLENOID VALVE, VVD, 810 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient & fluid temperature: -10 to 50° C, Enclosure: IP67 (based on IEC529), 3 Position Exhaust Center, 4/5 PORT SOLENOID VALVE, VVD, 732 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient & fluid temperature: -10 to 50° C, Enclosure: IP67 (based on IEC529), 3 Position Pressure Center, 4/5 PORT SOLENOID VALVE, VVD, 252 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient & fluid temperature: -10 to 50° C, Enclosure: IP67 (based on IEC529), 2 Position Double Solenoid, 4/5 PORT SOLENOID VALVE, VVD, 163 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient & fluid temperature: -10 to 50° C, Enclosure: IP67 (based on IEC529), 2 Position Single Solenoid, 4/5 PORT SOLENOID VALVE, VVD, 120 lb
allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Compressor Set for HRS150-A/W-#-40, CHILLER, 729, 33
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient & fluid temperature: -10 to 50° C, Enclosure: IP67 (based on IEC529), 3 Position Exhaust Center, 4/5 PORT SOLENOID VALVE, VVD, 252 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MOUNTING SCREW, VALVE, SS5V2 MANIFOLD SV2000, 12, SS5V2 OTHER SIZE RATING, .00473 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .05086 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .12540 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MFLD BLOCK, VALVE, SS5V2 MANIFOLD SV2000, 11, SS5V2 OTHER SIZE RATING, .20680 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .12540 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .03685 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .12540 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .02537 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MTG SCREW, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .00343 lb