Byte 80 Output 24 to 31 Total 77 bytes Total 81 bytes -83No.EX-OMA1023 Diagnostics By changing the diagnosis switch, the diagnostic data shown below is assigned to the input data of the I/O map.

The switch output load current (OUT1) has exceeded 80 mA. Turn off the power supply and remove the cause of the over current. Then supply the power again.

The switch output load current (OUT1) has exceeded 80 mA. Turn off the power supply and remove the cause of the over current. Then supply the power again. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. Overcurrent error Function Setting The switch output load current (OUT2) has exceeded 80 mA.

Flow setting (3 step setting mode) Function setting (Function selection mode) Other functions [1000] 1000 L/min (PFMB7202) [F 1] OUT2 over current error The switch output (OUT2) load current has exceeded 80 mA. [ 10] 10 L/min (PFMB7201) [ 25] 25 L/min (PFMB7501) Do not use the product for flammable fluid. Fire or explosion can result.

OUT1 over current error The switch output (OUT1) load current has exceeded 80 mA. Turn the power OFF and remove the cause of the over current.

Insert the corresponding wire colour shown in the table into the pin number printed on the sensor connector, to the bottom. more than 20 mm Cover The switch output load current (OUT1) has exceeded 80 mA. [1ot ] Reversed output (OUT1) [1_n] Reversed output Turn off the power supply and remove the cause of the over current. Then supply the power again.

The identification code of the product is displayed. 4 Set value or 3 4 or 3 Set value Display instantaneous flow Display accumulated flow Output mode (OUT2) Reference condition 2 OUT1 over current error The switch output load current is more than 80 mA (OUT1). Turn the power off and remove the cause of the over current. Then turn the power on again.

Reduce the flow. 4 Set value or 3 4 Set value or 3 Caution Non-Reverse output Reverse output Accumulated pulse output mode Instantaneous output mode Accumulated output mode OUT1 over current error The switch output load current is more than 80 mA (OUT1). Turn the power off and remove the cause of the over current. Then turn the power on again.

Hysteresis Setting of hysteresis can prevent chattering. 5% of rated flow 1 41 mm Approx. 1 second Approx. 3 seconds (the output remains off for this period) 11/4 54 mm OUT2 over current error A load current of 80 mA or more is flowing to the switch output (OUT2). *: Display colour is linked to the setting of OUT1, and can not be selected.

[F 2] Setting of OUT2 OUT1: Black OUT1 over current error A load current of 80 mA or more is flowing to the switch output (OUT1). Turn the power off and remove the cause of the over current. Then turn the power on again.

In general, 80 to 100 mesh (150 to 180 m) filters are recommended. When transferring a coagulable liquid, take measures to prevent it from coagulating in the pump. Precautions to observe when transferring slurry Basically, it is not recommended to transfer slurry because this will result in seating failure and wearing of the check valve and accumulation of particles.

Ratio of discharge amount to fresh water (%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPa s) mPas Silicone oil Lubricant Vegetable oil Water 60 to 80 1 6080 340 950 1500 3150 9800 Viscosity (mPa s) cp 0 100 1000 10 150 | 2650 45 | 2 3000 4500 Tomato juice Honey Medical barium Wooster source Cutting oil 4500 45 2000 to 3000 8 - 8.

Ratio of discharge amount to fresh water(%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity(mPa s) mPas Silicone oil Lubricant Vegetable oil Water 1 60 to 80 340 950 1500 3150 980 0 Viscosity (mPa s) 0 100 1000 10 Medical barium Cutting oil Tomato juice Honey Woosterource 4500 45 150 2000 to 3000 2650 8 - 8.

25 75 50 n 1 0 8 6 4 2 50 67.5 <69.5> L1 8 67.5 <69.5> 64.9 L2 4 x 9 (for M8 mounting) 3 port valve 2 port valve 64.9 50 8 10.5 Leakage detection port Pilot port C4: 4 One-touch fitting C6: 6 One-touch fitting G1/4 (RETURN port) G1/4 (IN port) 30 31 0.5 to 2 0.5 to 2 10 10 0.5 to 2 0.5 to 2 n-1 5 3 1 1 2 122.2 <124.2> 142.2 <144.2> 22.6 100 120 80 25 75 n 6 4 2 3 Gate valve Aluminum + hard

capacity(HRS030 W-20-(BJMT)) 9.4 Cooling capacity HRS Series 9-6 HRX-OM-R016 Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRS030--20-(BJM) 0.3 Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] 20 Outlet60Hz 0.2 Pump head[m] 10 0.1 Outlet50Hz Return port 0.0 5 0 10 20 30 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS030--20-(BJM)) 9.6.2 HRS030--20-T 0.8 80

HRR012/018-A-10-* 45 70 HRR012/018-A-20-* 61 80 HRR012/018-A-20-U 50 80 Model A B In the case of option Z, without bypass valve Fig. 9-1 Outline dimensions (HRR012/018-A-10/20-) 9.2 Outline dimensions HRR Series 9-6 HRX-OM-W002 Chapter 9 Documents 9.2.2 HRR012/018-W-10/20For Option Y(With feet and no Rack Mounting bracket), refer to [6.5 Option Y(With feet and no Rack Mounting bracket).

Using this product at high temperatures (40 to 80 oC) may cause burns. Do not touch the surface until it is cooled down to less than 40oC. Connect IN and OUT correctly. (Make sure that reverse flow will not be generated) Make sure that back flow will not be generated. The element might break due to exposure to back flow.

For proper sealing during the replacement of the element, clean off any paint etc which is stuck to the threads of the O-ring seat surface and the cover connecting part. 3.Temperature Using this product at a high temperature (40 to 80 oC) may cause burns.

Table 5.21-25 Setting of operation of the contact output signal 1 Set value Explanation Default N.O. type N.C. type 5.21 Communication Function HRS Series 5-80 HRX-OM-W032 Chapter 5 Display and Setting of Various Functions Setting/Checking: Selected alarm for contact output signal 1 49. Press the [SEL] key once.

CG1A-Z 1) 2) 3) 4) 5) 6) 7)2 2 2 20 2 1.5 25 3 1.5 32 4 1.5 40 5 1.5 50 3 3 63 4.5 3 80 5 4 100 5 4 P6.1. 9 3 20 25 32 40 50 63 80 100 0.28 0.41 0.66 1.20 2.00 3.40 5.90 9.90 0.11 0.18 0.29 0.52 0.91 1.54 2.71 4.54 (J) R0.35 R0.56 0.91 1.80 3.40 4.90 11.80 16.70 H0.42 H0.65 0.11 0.18 0.29 0.52 0.91 1.54 2.71 4.54 (3) 2-7. 10 2-8. 345 P13, 4 CDG1 P15, 6 <> <> D-G59D-G5PD-K59D-G5BA