-10 (FKM) 1.3 x 10-8 External 1.3 x 10-11 (FKM) 1.3 x 10-9 w, e w e Nil A B C P1 70W 1.3 x 10-8 1.3 x 10-11 (FKM) 1.3 x 10-9 Kalrez 1.3 x 10-10 (FKM) Q1 R1 R2 R3 S1 T1 4079 SS592 SS630 SSE38 1232-70 3310-75 Note 1) Values at ambient temperatures, excluding gas permeation.
x 0.8 Rc 1/8 Symbol M5 01 OUT IN Gauge port positions are indicated with the knob on the top side.
x 0.8 Rc 1/8 Symbol M5 01 OUT IN Gauge port positions are indicated with the knob on the top side.
mounting hole 40 8.5 20 28 72.5 (when set = 75.5) Bleed exhaust hole 6.5 28 41 1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3
Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Sensor range Option None 0 1 2 3 Positive pressure [0 to 1 MPa] Vacuum [0 to 101 kPa] Low pressure [0 to 101 kPa] Compound pressure [101 to 101 kPa] Nil Port size Sensor cable (3 m) M5 R06 R07 M5 x 0.8 6 reducer 1/4 inch reducer L ZSE ISE Option ZSP Connector for pressure sensor controller (1 pc.) + Sensor cable (3 m) Description Part
VE 4 point preset output pressure Applicable in the programming function with up to 20 steps. 10 bit parallel input signal (maximum) Pressure can be set with 2 10 = 1024 steps. VY1 G Step 1 Step 2 Step 3 Step 4 . . . . . . . . . . . . .
Time Zero span correction function Deviation of the zero span point of the sensor can be corrected. 10 bit parallel input Keylock function Up to 10 bits of parallel input is possible from PLC. Pressure can be set with 2 10 = 1024 steps. To prevent erroneous operation, operation on the key can be disabled.
PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No. PF-OMK0003CN-E FG DC(+) OUT() DC(-) 15V 1k -17No. PF-OMK0003CN-E DC(+)DC(+) (OUT1) IN (20 ) -18No.
Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No.
AMD LLB4-1-PRVSF AMH V2 AME 72.1 Mounting hole for 4 x M5 AMF ZFC 58 70 SF 1 A Valve open and locked position 508 10 10 SFD 95 (Lever operating direction) Max. 132 Connection part Rc 3/8 (NPT 3/8) LLB LLB A Hand valve Valve closed position AD Air operated valve 3.5 GD Clean regulator With flow adjuster Pressure outlet port Rc 1/8 One-touch fitting 12 Digital flow switch PA pilot port Rc 1
Also, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejectors exhaust unit. 3.2 (Straight) KJS23-M5 VVQ1000-50A-C3 4 (Straight) KJS04-M5 VVQ1000-50A-C4 6 (Straight) KJS06-M5 VVQ1000-50A-C6 3.2 (Elbow) KJL23-M5 VVQ1000-F1-LC3 4 (Elbow) KJL04-M5 VVQ1000-F1-LC4 !
Compatible cable Cord O.D.:3.5 to 7 (Reference) 0.5mm2, 2-core or 3-core, equivalent to JIS C 3306 Part no. for One-fitting for 1(P) port and Silencer for 3(R2,R), 5(R1) port. (2) Silencer for 3(R2,R), 5(R1) port Series (1) One-touch fitting for 1(P) port Silencer One-touch fitting VQZ100/1000 KQ2H06-M5 AN120-M5 KJS04-M5 VQZ200/2000 KQ2S06-01S INA-25-46 IN-457-32for 6 VQZ300/3000 KQ2H08-02S
06 6 (mm size) KJH06-M5 Specifications Model PPA100 for high press.
Note 2) Fixed unit For vacuum/compound pressure: kPa For positive pressure: MPa One-touch fitting type One-touch fitting None Applicable tubing material Applicable tubing size Symbol None None Nil Nylon Soft nylon Polyurethane 04 4 (mm size) KJH04-M5 06 6 (mm size) KJH06-M5 Specifications Model PPA100 for high press.
(V) 24 Allowable voltage fluctuation -10 to 10% Power consumption (W) 0.4 [Starting 0.4, Holding 0.1] Please refer to page 1367 of Surge voltage suppressor the Best pneumatics catalogue.
V114-5LU Electrical entry L shaped plug connector (L) Coil rated voltage [V] 24 Allowable voltage fluctuation -10 to 10% Power consumption [W] 0.4 [Starting 0.4,Holding 0.1] Surge voltage suppressor Please refer to page 1367 of the Best Pneumatics catalogue. Indicator LED LED 14 - 4-3.
Rated load current Max. 62 mA (1.5 W) / point Max. 0.5 A (12 W) / point -10 to +50 oC (solenoid valve type) Operating ambient temp. Power block (EX9-PE1) NOTE Specifications Item When conformity to UL is necessary the SI unit must be used with a UL1310 Class 2 power supply.
PF2M7-B.eng:PF2M7-B.eng.qxd 21/04/09 14:02 1 Before Use Digital Flow Switch PF2M7## Wiring Wiring of connector Connections should only be made with the power supply turned off. Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.
Note 2) Values under the following conditions: Fluid: Water; Filtration: 20m; Pressure drop: 0.02MPa or less How To Order Installation Diagram FN1 1 0 1 N 10 S 020 Housing material 1 SUS304 Element type 0 Cylindrical type 1Note) Step type Pressure gauge Nil Without pressure gauge (with plug) GNote) G46-15-02 (wetted parts: Brass) Note) Only 5m of filtration is available.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Drain cock Nil Metal bowl 2 ZL Thread type Port size Nylon bowl 6 Drain guide (Rc 1/4) 02 1/4 Nil J Rc ZY 03 3/8 F Flow: Right Left R G 04 1/2 N If ordering two options or more, indicate symbols numerically and alphabetically.