auto switch Solid state auto switch Size Rotation A B Operation Hysteresis angle A B Operation Hysteresis angle m angle m angle 90 15 21.5 19 25.5 10 75 3 180 18 31 22 35 63 12 360 25 52.5 29 56.5 90 18.5 27 22.5 31 15 69 3 180 22.5 39.5 26.5 43.5 52 9 360 30.5 64.5 34.5 68.5 90 36 48.5 40 52.5 20 56 4 180 42 67.5 46 71.5 41 9 360 55.5 106 59.5 110 90 43 59 47 63 30 43 3 180 51 82 55 86 32
Angle adjustment Range With adjustment bolt 190 With internal shock absorber With external shock absorber 96, 186 Maximum Rotation With adjustment bolt 0.2 to 1.0s/90 0.2 to 0.2 to 0.2 to Rotation Time Adjustmen t Range 1.5s/90 2.0s/90 2.5s/90 With internal shock absorber 0.2 to 0.7s/90 0.2 to 1.0s/90 With external shock absorber 0.2 to 1.0s/90 Note4) Cylinder bore size 15 18 21 25 28 32
Size 10,15 Cross recessed No.0 screw Size 20,30,40 Cross recessed roundhead screw Bearing retainer Bearing Shaft Cover assembly End cover assembly Hexagon socket head bolt Bearing Body Piston assembly Fig.12 -32- Assemble procedure 1Clean each component sufficiently before assembled to prevent a dust from attaching.
MHF2-8D MHF2-12D MHF2-16D MHF2-20D mm 8 12 16 20 MPa 0.150.7 0.10.7 oC -1060 mm 1) 0.05 120 c.p.m. 120 60 2) 1 N 19 48 90 141 8 12 16 20 () mm 16 24 32 40 32 48 64 80 65 155 350 645 85 190 445 850 3) g 120 275 650 1,225 1) 0.15mm 2) 0.5MPaL=20mm 3) 4 2 2-1 1. ( ) 2. 3. 4. 2-2. 1. 2. (1) (2) (3) 5 3. 4. 5. 6. (1) (2) ,2 , 7.
60 20 56 76 280 MHL2-10D1 40 78 118 345 10 40 MHL2-10D2 60 96 156 425 MHL2-16D 60 30 68 98 585 MHL2-16D1 60 110 170 795 16 40 MHL2-16D2 80 130 210 935 MHL2-20D 60 40 82 122 1,025 MHL2-20D1 80 142 222 1,495 20 40 MHL2-20D2 100 162 262 1,690 MHL2-25D 60 50 100 150 1,690 MHL2-25D1 100 182 282 2,560 25 40 MHL2-25D2 120 200 320 2,775 MHL2-32D 30 70 150 220 2,905 MHL2-32D1 120 198 318 3,820 32
Specifications 1-1 Specifications Specifications Model MHT2-32DZ MHT2-40DZ MHT2-50DZ MHT2-63DZ Cylinder inside diameter (mm) 32 40 50 63 Action Double acting Fluid Air Operating pressure (Mpa) 0.1 to 0.6 Ambient and fluid temperature (oC) 5 to 60 Lubrication Lubrication not required.
Note 5) When Nil is selected, the product will not come with a built-in magnet for an auto switch, and so a mounting bracket cannot be L E F S H 25 G B 200 C N K R1 CDH7T Motor type Lead[mm] Size Accuracy Motor mounting position Nil Basic type 16 25 32 40 Symbol LEFS16 LEFS25 LEFS32 LEFS40 Nil In-line High performance H High-precision type R Right side parallel G battery-less absolute H 20
Green On Green Red On Off Communication error is flashing detected for all controllers (LEC), or IF communication speed of the controller is incorrect. 32 - 10. Mode 10. 1 Outline This unit has 3 types of operation mode.
Apparent power Apparent power (VA) 100V200V Voltage(V) Power con-sumption(W) 12 Inrush 50Hz 100 AC 24 32 48 60Hz 90 DC Holding 50Hz 20 13.2 60Hz 14 100 110 Use the actuator with allowable kinetic energy or less. Refer to 2-6. Allowable kinetic energy (Page 11) W a r n i n g Confirm the specifications. These product are designed only for use in compressed air systems (including vacuum).
No.1 No.2 No.3 No.4 No.5 No.6 1 2 4 8 16 32 0 0 0 0 0 0 0 1 1 0 0 0 0 0 MAC ID 2 0 1 0 0 0 0 62 0 1 1 1 1 1 63 1 1 1 1 1 1 Communication speed setting (switches No. 7 to 8) Set the DeviceNetTM communication speed with a binary code of 125 kbps or 250 kbps or 500 kbps.
The maximum input point is 32.
One SI unit can be connected with manifold valves with up to 32 outputs and the input output I/O units with maximum 10 units. SI unit: Performs Fieldbus communication and solenoid valve manifold ON/OFF output. Digital input unit: For connecting sensors with switch output capability. PNP and NPN types are available.
56 or more 44 or more 26 or more 20 or more 3/16 67 or more 52 or more 38 or more 24 or more 6 84 or more 66 or more 39 or more 30 or more 1/4 89 or more 70 or more 57 or more 32 or more 3)Grasp the tubing, and slowly push it straight into the One-touch fitting until it comes to a stop. 4)Pull the tubing back gently to make sure it has a positive seal.
No.VQC1000V-OMM0002-B PRODUCT NAME Solenoid Valve MODEL/ Series VQC1000/2000 Series (Pilot Valve V100) Contents Safety Instructions -2,3 Precautions on Design -4,5 Selection -4,5 Mounting -5 Piping -5,6 Wiring -6 Lubrication -6,7 Air Supply -7 Operating Environment -7 Maintenance -7,8 Specific Product Precautions -915 Valve construction -16,17 Manifold Options -1830 Trouble shooting -31, 32
The number of available node is up to 32 stations per segment (without repeater) or 126 stations (with repeater). NOTE 1. Be sure to turn off the power before setting the switches. 2. Be sure to set these switches before use. The factory default settings are all "OFF" or "0". 3.
High pressure switch IDU Series 5-2 Cause and countermeasure of errors 5 3 IDX-OM-W028 Air Dryer 6 References 6 References 6-1 Specifications IDU22E~75E-23 Model Specification IDU22E-23 IDU37E-23 IDU55E-23 IDU75E-23 Air Flow Rate m3/min (ANR)(Note 1) 50Hz 3.9 5.7 8.4 11.0 Rated Condition Operating Pressure MPa 0.7 Inlet Air Temperature 55 Ambient Temperature 32 Pressurized Dew Point 10
IDU Series 9-1 Safety instructions 91 IDX-OM-W013 Air Dryer 9 Specification for Option L 9-3 Installation of heavy duty auto drain 1) Hold the hexagon-head part (width across flats: 32) at port Rc1/2 of the air dryer with spanner. Then install nipple, ball valve (width across flats: 25). Note 1) Put up the seal tape or the sealant to the nipple.
Specifications 32 Dimensions 34 -1No.SFOD-OMO0004-B Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
If max. number of connected slave is 32(IN16/OUT16), the setting range is 0 to 15. For master unit CQM1 The number of channel occupied by PLC of master unit and the number of point occupied by one node address are related additionally.
P368010-32 7.010.0 Flameproof packing type P368010-33 10.112.0 Packing connector unit Table4 Flameproof packing type cable ground (Option) Cable Flameproof packing type connector unit 17 7.Adjustment Caution ! (1) For this positioner, span and zero point adjustment of each actuator is necessary.