SMC Corporation of America
Elite Part Number Search
Search Results "PFM510-C6-2-A-W"

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., 2-Color Digital Flow Switch for Air, PFM, DIGITAL FLOW SWITCH, 95.00000 lb

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), .66138 lb

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 0.2 to 10 (5), Accessory: None, Option: None, Analog Current Output(mA): None

[Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Straight), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,

Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Elbow), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,

Structure: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 0.2 to 10 (5), Accessory: None, Option: None, Analog Current Output(mA): None