SMC Corporation of America
Elite Part Number Search
Search Results "PSE563-B2-28-C2"

[Features] · Quick response: valve response time of 5 ms, vacuum response time of 28 ms · Energy-saving: 17% reduction in air consumption, 21% increase in vacuum pressure reached · Compact and lightweight: 46 g · Equipped with vacuum pressure switch; can copy up to 10 switches simultaneously

.· Compact and lightweight: Size reduced by 28% (88 cm³) and weight by 59% (81 g).· Reduced wiring for both single units and manifolds.· Once the supply valve is switched ON, the vacuum generation state is maintained even if the power is cut off. This helps reduce power consumption.

Bore sizes: 12, 16, 20, 25, 32, 40 mm; Standard adjustable stroke range: 10 mm (all bore sizes); X138 option, adjustable stroke range: 26 mm (12, 16 bore);; 28 mm (20, 25 bore); 44 mm (32 bore); 40 mm (40 bore); Shock absorber option; Auto switch capable

Bore sizes: 12, 16, 20, 25, 32, 40 mm; Standard adjustable stroke range: 10 mm (all bore sizes); X138 option, adjustable stroke range: 26 mm (12, 16 bore);; 28 mm (20, 25 bore); 44 mm (32 bore); 40 mm (40 bore); Shock absorber option; Auto switch capable

Bore sizes (nominal): 1/4", 3'8", 5/8", 3/4", 1", 1-1/4", 1-1/2"; Stroke length: 2", 4", 6" 8", 10", 12", 14", 16", 18", 20", 24", 28", 32", 36", 40", 60"; Minimum operating pressure: 26 psi; Speed: 2 ~ 20 inch/sec.; Auto switch capable  

Basic vacuum switch with rotary adjustment of a supply level voltage output signal; Vacuum range: -80 to -27 kPa; Output: switched supply level voltage; Power supply requirement: 4.5 to 28 VDC (solid state) or 100V AC/DC (reed); Repeatability: ±10% or less; Port sizes: 1/8 RC or 1/8 NPTF male, or ZM genertor mountable

The finger opening angle ranges from 28° to -3°. Bore sizes: 32, 40, 50, 63 mm; Vertical, axial, lateral mounting; Auto switch capable

LEMH: Single axis linear guide provides higher moment resistance than LEMC ; LEMHT: Double axis linear guide provides higher moment resistance than LEMH ; LEMH & LEMHT: Body sizes: 25, 32 ; LEMH & LEMHT: Table height: 28 mm (25); 37 mm (32) ; LEMH & LEMHT: Maximum stroke: 1000 mm (25) ;

Cam follower guide offset from drive for low table height and increased work load ; Body sizes: 25, 32 ; Table height: 28 or 37 mm ; Maximum stroke: 2000 mm ; Maximum speed: 1000 mm/s

HRSH Air-cooled recirculating chillers offer a cooling capacity range of 10.5 to 28 kW. Coolant and refrigeration circuits are included in a compact and lightweight package. Extracted heat is air cooled. An inverter provides demand-based rotation control for the compressor, pump and fan, offering substantial energy savings. Electric options ensure global power supply compatibility.

LEMH: Single axis linear guide provides higher moment resistance than LEMC ; LEMHT: Double axis linear guide provides higher moment resistance than LEMH ; LEMH & LEMHT: Body sizes: 25, 32 ; LEMH & LEMHT: Table height: 28 mm (25); 37 mm (32) ; LEMH & LEMHT: Maximum stroke: 1000 mm (25) ;

HRSH Air-cooled recirculating chillers offer a cooling capacity range of 10.5 to 28 kW. Coolant and refrigeration circuits are included in a compact and lightweight package. Extracted heat is air cooled. An inverter provides demand-based rotation control for the compressor, pump and fan, offering substantial energy savings. Electric options ensure global power supply compatibility.

HRSH Air-cooled recirculating chillers offer a cooling capacity range of 10.5 to 28 kW. Coolant and refrigeration circuits are included in a compact and lightweight package. Extracted heat is air cooled. An inverter provides demand-based rotation control for the compressor, pump and fan, offering substantial energy savings. Electric options ensure global power supply compatibility.

Basic vacuum switch with rotary adjustment of a supply level voltage output signal; Vacuum range: -80 to -27 kPa; Output: switched supply level voltage; Power supply requirement: 4.5 to 28 VDC (solid state) or 100V AC/DC (reed); Repeatability: ±10% or less; Port sizes: 1/8 RC or 1/8 NPTF male, or ZM genertor mountable

Bore sizes: 12, 16, 20, 25, 32, 40 mm; Standard adjustable stroke range: 10 mm (all bore sizes); X138 option, adjustable stroke range: 26 mm (12, 16 bore);; 28 mm (20, 25 bore); 44 mm (32 bore); 40 mm (40 bore); Shock absorber option; Auto switch capable

Bore sizes: 12, 16, 20, 25, 32, 40 mm; Standard adjustable stroke range: 10 mm (all bore sizes); X138 option, adjustable stroke range: 26 mm (12, 16 bore);; 28 mm (20, 25 bore); 44 mm (32 bore); 40 mm (40 bore); Shock absorber option; Auto switch capable

0.014 to 0.7 MPa)], Material: S (Body: 316L SS Secondary Remelt; Poppet: 316L SS; Diaphragm: 316L SS; Nozzle: 316L SS), Surface Finish: 15 μin. (0.4 μm), Standard, Ports: 4PW [4 Ports (1-In; 2-Out; 3-Gauge Port In; 4-Gauge Port Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face Seal, Female), Gauge Port, Inlet: 40 [0 to 4000 psig (0 to 28