Plug-in Terminal 3/8, Non-plug-in Standard 3/8)
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8,
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in Terminal 3/4,
3/4, Non Plug-in Standard 3/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: C (Locking Knob Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in
Plug-in Terminal 3/8, Non-plug-in Standard 3/8), Thread: T (NPTF)
Terminal 3/4, Non Plug-in Standard 3/4), Thread: T (NPTF)
Plug-in Terminal 3/8, Non-plug-in Standard 3/8), Thread: T (NPTF)
Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: T (NPTF)
3/4, Non Plug-in Standard 3/4), Thread: T (NPTF)
: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: T (NPTF)
Plug-in Terminal 3/4, Non Plug-in Standard 3/4)
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in Terminal 3/4,
Terminal 3/8, Non-plug-in Standard 3/8), Thread: T (NPTF)
Model: 20 (1500 L/min), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 2 (Switch Output NPN), Thread: F [G(PF)], Port Size: 3 [3/8 (2000,3000)], Accessory: None, Cable Connector: S (Straight Style 3m), Pressure Display Unit: 3 (Bar)
Model: 20 (1500 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 3 (Switch Output PNP), Thread: F [G(PF)], Port Size: 3 [3/8 (2000,3000)], Accessory: B (Flat Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 3 (Bar)
Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 3 (Switch Output PNP), Thread: F [G(PF)], Port Size: 3 [3/8 (2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 3 (Bar)
Model: 20 (1500 L/min), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: F [G(PF)], Port Size: 3 [3/8 (2000,3000)], Accessory: B (Flat Bracket), Cable Connector: N (w/oCable Connector), Pressure Display Unit: 3 (Bar)