SMC Corporation of America
Elite Part Number Search
Search Results "ZS-26-A"

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: C4L (ø4 One-touch Fitting, Elbow Type), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread, Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)], Operation Manual: Y (w/o Operation Manual, w/o Calibration

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)], Operation Manual: T (w/o Operation Manual,

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]

Part Number Description: CONNECTOR   Product Line: I   Product Line Description: INSTRUMENTATION   Family Code: 835   Family Description: PSE100/PSE510 PRESSURE SWITCH   Class Code: 21   Part Code: 2   Reference Code:  J   Click here to report information errorImage shown may not match exact part number

Manual override (L4) L2 5 (Rail mounting hole pitch: 12.5) L1 SS5Y5-M45Stations B Pitch SY5000 Pitch SY3000 L dimension: Formulae for L1 to L4 L3 = 12.5 x n1 + 16 x n2 + 70 15.5 26 26 15.3 17 P=16 P=12.5 16.9 Button for DIN rail release L3 12.5 M= ( + 1) Omit decimals 31.5 32 71.1 [78.1] 71.5 [78.5] 14.5 R R A A A A A A L1 = 12.5 x M + 23 L2 = L1 10.5 L4 = (L1 L3)/2 B B B B B B P P A, B

A A A A A Note) For details of the applicable tubing sizes, refer to page 945.

R Y T A B L E S E R I E S M S Q A 1 0 , 2 0 , 3 0 , 5 0 Model DA(h8) HD HB DB(h8) DC(h8) DD(h8) HA MSQA10 52.5 18.5 45 46 20 15 10 63 26 60 61 MSQA20 28 17 15.5 67 27 65 67 32 22 16.5 MSQA30 76 30 75 77 35 26 17.5 MSQA50 A L L D I M E N S I O N S E X C E P T F O R T H I S TA B L E A R E T H E S A M E A S F O R B A S I C M O D E L Courtesy of Steven Engineering, Inc. !

Also, tighten with a torque of 0.05 to 0.1 Nm. As a guide, turn about 90 past the point at which tightening can be felt. 8-25-26 26 Series MGZ/MGZR Specific Product Precautions 1 Be sure to read before handing. Mounting Selection Caution Caution 1.

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: Bracket for

Type: -, Application: -, Mounting Orientation: -, Voltage: -, Specification: -, Actuation: -, Status at Power Off: -, Valve Positions: -, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Connecting Tube Diameter: -, Driving Type: -, Pilot Air Supply: -, Seal Type: -, Manual Switch: -, Plumbing: -, Flow Coefficient (Cv): -, Lead wire electrical entry: -, Manual: -, Bracket

28.5 29 32.5 23.5 28 28.5 A 34.5 25.5 30 30.5 B 6 6.5 10.5 13.5 16.5 19.5 B 12.5 15.5 18.5 21.5 A 29 29.5 33 24 28.5 29 B 6.5 7 11 14 17 20 A 26 26.5 30 21 25.5 26 B 3.5 4 8 11 14 17 A 19.5 24 24.5 B 9.5 12.5 15.5 A 31.5 22.5 27 27.5 B 9.5 12.5 15.5 18.5 A 35.5 26.5 31 31.5 B 13.5 16.5 19.5 22.5 MK220 MK225 MK232 MK240 MK250 MK263 Auto Switch Mounting Bracket Part No.

U D-A79W D-F7WV D-F7V D-F7BAVL A B B A Proper auto switch mounting positions (mm) D-A7H, D-A80H D-A73C, D-A80C D-F7 D-F7V, D-F7W D-F7WV D-J79 D-J79C, D-J79W D-F7BA D-F9 D-F9V D-F9W D-F9WV D-A7 D-A80 D-A9 D-A9V D-A79W D-F7NTL D-F7F D-F9BAL Bore size (mm) A A A B A A A A B A B B B B B B 26 25 18 20.5 18.5 21 20 24 23 16 19 32 31 27.5 24.5 20.5 28.5 30 23 25.5 21.5 26 27 23.5 24.5 26 19 22 40