SMC Corporation of America
Elite Part Number Search
Search Results "VV5K3-42-01-C6"


Type 41, 42, and 43 base mounted manifold gasket part number.: SY□000-GS-2(-Q) (10 pcs./set: mounting screws and gasket)
Valve part numbers: SY3140, SY5140, SY7140, SY9140, etc.
Note) For type 41 and 42 SY5000/7000 series manifolds, when there is a “-Q” (CE-compliant product) suffixed to the part number, suffix a “-Q” to the gasket assembly part number as well .

Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 (CCW) to 1(CW). Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -24- The origin offset means the value of the origin.

Replacement Procedure 42 9. Specifications 47 10. Port Layout 52 11. Exhaust/Flow Rate Characteristics 62 11.1. Ejector Exhaust Characteristics/Flow Rate Characteristics 62 11.2. Vacuum Pump Flow Rate Characteristics 64 11.3. Vacuum Release Flow Rate Characteristics 64 12. Limitations of Use 66 13. Troubleshooting 67 -1No.

Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 to 1. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -28- The origin offset means the value of the origin.

Metric size Inch size P . 15-11-3 3.2 With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Use 1/8" tube. 23 04 06 08 10 12 01 03 05 07 09 11 13 4 6 8 10 12 Flow Direction Symbols on Body JIS Symbol Symbol 15-9-10 2 Speed Controller with One-touch Fittings In-line Type Series AS Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5

M5, R(PT) 1/8, R(PT) 1/4 Mounting bracket .M5 style only 3.6-1 Digital Pressure Sensor GS40 How to Order GS40 X202 Digital Pressure Sensor PSE ZSE4 ISE4 Port size Optional M5 (Female) R(PT)1/8 R(PT)1/4 5m-long lead wire X202 M5 01 02 ZSE5 ISE5 ZSE6 ISE6 Accessories B None Bracket (M5 style only) ZSE3 ISE3 GS PS Specifications ISA Model GS40-M5 GS40-01 GS40-02 ZSE1 ISE1 Air or inert gas Fluid

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs. G46-10-01 2 pcs.

G <& C D, T G, C S L, Z S L, Z 8 8 8 8 8 8 8 8 8 8 8 8 T 9 '01 !" % % :"; % %%& !" % % :; S Note) 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) How to Order Manifold Arrangement of solenoid 9= Write both the base part number and the solenoid valve to be mounted or blanking plate part number. !"

Filtration rating has to be 5m or smaller. 3(R) Model VHS2500 VHS3500 VHS4500 VHS5500 A 60 78 85 136 B 20 29 32 56 C 12.8 12.8 12.6 32 D 40 53 70 90 E 44 53 64 80 F 33 42 49 65 G 28 29 36 54 H 7.5 7.5 10 10 3.6-18

AXT503-23A G36-10-01 AXT510-32A G36-10-01 Flow control interface Pressure gauge Model Selection Applicable cylinder bore size: 25 to 125 For model selection, refer to Selecting Electro-pneumatic Proportional Valve on page 706. 704 Series VER2000/4000 5 Port Electro-Pneumatic Proportional Valve How to Order Port size Nil Without sub-plate 02 03 1 4 3 8 ARJ VER2000 02 Series VER2000 AR425

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 01, Port Size: 01 (Rc 1/8), Thread: T (NPTF)

Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 01, Port Size: 01 (Rc 1/8)

Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 01, Port Size: 01 (Rc 1/8), Thread: N (NPT)

VH*-OMX0068-A PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-R,Z)-D VHS30-(F,N)02~(F,N)03(-R,Z)-D VHS40-(F,N)02~(F,N)04(-R,Z)-D Contents Page 1. Safety Instructions 1~5 2. Application 6 3. Specifications 6 4. How to Order 7~8 5. Construction / Parts List 9 6.

Filter plate 2 Series FN1 Flow Characteristics (Initial Value) Test fluid: Potable water Liquid temperature: 17 to 20C (room temperature) Test method: Per P/A test method (sanitary test stand) Element length 250mm: FN111-10-S Element length 500mm: FN112-10-S .1 .1 .05 .05 FN111-10-S005 (5m) Pressure loss (MPa) Pressure loss (MPa) FN112-10-S005 (5m) FN111-10-S020 (20m) .01 .01 FN112-10-S020

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

w Body size 20 30 40 50 60 AFF Nominal filtration rating: 1 m V V V V V Water droplet removal ratio: 99% AM Nominal filtration rating: 0.1 m V V V V V Oil mist concentration on the outlet side: 1 mg/m3 q Filter type AMD Nominal filtration rating: 0.01 m V V V V V Oil mist concentration on the outlet side: 0.1 mg/m3 + e Thread type Nil Rc V V V V V N*1 NPT V V V V V F*2 G V V V V V + 01