SMC Corporation of America
Elite Part Number Search
Search Results "RZQD63TN-200-80"

RSGBore size: 40, 50 (26 + Stroke) 16 (12) Workpiece transfer direction 2 16 (Rc 1/8, NPT 1/8, G 1/8) M45 x 1.5 9 Stroke 60 0 0.05 (Rc 1/8, NPT 1/8, G 1/8) 25 A 80 60 8 38 18 60 38 + Stroke 4 x 9 through 67 + Stroke 80 105 + 2 stroke Built-in One-touch fittings QB Tubing O.D.

Fig. 8-8 Cooling Capacity (HRL100/200/300-A-20) Documents HRL Series 8-8 HRX-OM-Y098 Chapter 8 Documents 8.5 Pump Capacity 8.5.1 HRL100-A-20 CH1 0.6 60 0.5 50 Circulating fluid outlet Pressure [MPa] 0.4 40 Lifting head [m] Usable flow rate range 0.3 30 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow[L/min] Fig. 8-9 Pump capacity(HRL100

This parameter is fixed when shipped, and cannot be modified. (200) Operation direction Direct3 (dir) or Reverse4 (rvS) can be selected. The default when shipped is direct (dir). setting 100% 200=dir 200=rvS Stroke 0% 0% 100% 0% 100% Input current Fig. 24 When the operation direction is modified, it is reflected on each item in accordance with Table 9.

SY3120-C6 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5120-01 800 700 600 500 400 300 200 100 0 SY7120-02 800 700 600 500 400 300 200 100 0 SY9120-03 Base mounted Bore size Series CJ2 Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load rate: 50% Stroke 1000 mm 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 Series MB/CA2 Pressure 0.5 MPa Load

Allowable power supply fluctuation: 3 phase 200 VAC +/-10% (50Hz); 3 phase 200 VAC to 220V +/-10% (60Hz) 3 phase with different voltage (IDF190 / 240D-9-): AC220V, 240V, 380V, 400V, 415V, 440V+/-10% Power supply cable specification Prepare the power supply cables below. Power supply cable: 10AWG (5.5mm2 or greater), cable O.D.

Check that the main circuit power supply (200 VAC) and controller circuit power supply (200 VAC) are wired correctly. When using the emergency stop SW etc. provided by customer, wire it to the EMG (Forced stop) of the input/output signal(CN6-1). When wiring, I/O connector(LE-CSNA) or I/O cable(LEC-CSNA-1) is required. (EMG (Forced stop) cannot be controlled with CC-Link.)

H4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 200 VAC 800/40 800/50 consumption (W) Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. H5 Initial power / Power 100 VAC 200/40 400/70 400/80 200 VAC 800/40 1600/80 1600/80 consumption (W) Note 1) Initial power and power consumption are nominal values.

NO 100 200 200 YES Whether cylinder speed is within speed level as shown in allowable kinetic energy graph. 100 Load(kgf) Load(kgf) 80 NO 100 100 80 63 63 50 YES 50 0 0 Whether loading is under specific load as shown in graph.

100 Standard Stroke Table Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1

Standard Stroke (mm) Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.

Standard Stroke (mm) Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.

Model Model L D L D TCU0805-1-N-X6 TCU0425-1-N-X6 1 N x 8 31 3 to 90 L x 5.2 + 200 N x 4 18 1 3 to 90 L x 5.9 + 200 8 5 TCU0805-2-N-X6 TCU0425-2-N-X6 2 42 3 to 40 L x 3 + 200 N x 16 L x 4.4 + 200 N x 8 2 3 to 90 4 2.5 28 TCU1065-1-N-X6 TCU0425-3-N-X6 1 52 3 to 45 L x 5 + 200 N x 10 N x 12 3 3 to 63 L x 2.9 + 200 28 10 6.5 TCU1065-2-N-X6 TCU0604-1-N-X6 2 3 to 35 N x 20 52 L x 3 + 200 N x 6

General line (low pressure) Locations requiring high pressure VBA Plant line (source pressure) VBA VBA (Two-stage pressure boost) 80 100 OUT 0.8 MPa E 0.5 MPa IN 0.5 MPa Operating pressure: 0.5 MPa Bore size: 100 Output 3850 N Operating pressure: 0.8 MPa Bore size: 80 Output 4000 N VBA Equivalent output When charging a tank or the like from a source at atmospheric pressure, a circuit with

Pressure 0.5 MPa Load factor 50% Stroke 500 mm VZS Average speed (mm/s) Series VFS VS4 40 50 63 80 100 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VQ7 VZ514--02 (Piping: 6 x 1 m) EVS VFN AS3301F-02-06/AN200-2 Speed controller/Silencer 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 8 x 1 m) AS3301F

Ph (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) * 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max. 50 2-/L) Max.200 Max.50 Sulfate ion (mgSO4 Acid consumption (Ph4.8) (mgCaCO3/L) Max.100 Max.50 Total hardness (mgCaCO3/L) Max.200 Max.70 Calcium hardness (mgCaCO3/L) Max.150 Max.50 Standards Ionic silica (mgSiO2/L) Max.50 Max.30 Iron (mgFe/L) Max.1.0 Max.0.3 Copper

Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa). It will be impossible to measure the gap when the operating pressure is less than 80 kPa or more than 220 kPa and the output will be OFF.

SFD100/200 AMG SFD200 only Rc 1/4 NPT 1/4 G 1/4 AFF Female thread SFD100/200 AM Different diameters for IN and OUT ports are Made to Order. For details, refer to page 326. AMD Relationship between Operating Temperature and Max.

(Note: l,/aximum speed for 80 & 100mm bore s ze is 28 in/sec ) Engineercd pislon Urethane bumpers available as I Available in I bore sizes and 9 different mounting styles.

300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.