Standard Strokes Bore size (mm) Standard strokes (mm) 20 32 40 50 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic Fluid Compatibility 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 80 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic fluid Compatibility
(C) 55 50 60 70 80 IDU3D to 6D 45 50 55 65 75 IDU8D to 15C 45 50 55 65 70 IDU22C1, 37C1 40 45 50 55 60 IDU55C, 75C Ambient temperature (C) Outlet air pressure dew point (C) 15 10 5 15 10 5 15 10 5 15 5 10 5 15 10 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 0.60 1.35 0.60 1.35 1.35 25 1.35 1.05 0.50 1.35 1.05 0.50 1.35 1.10 0.50 1.35 0.60 1.20 0.55 1.35 1.25 30 1.25 0.95 0.45 1.25 0.95
A DB BN BP BO DC eO eE F GA GB GC GO 10011500 50 136 Bore Size Stroke r.naecmm) (mm) WHhoot boot WHh boot GL GR J K MM 27 30 60 96 V V 44 16 32 10 as 15 26 54 40 500 20500 50 600 20-600 10 10 M8X1 .25 6 M14X1.5 32 35 70 108 V 'I, 52 20 40 10 95 17 27 59 32 35 86 11 5 V V 64 20 40 10 102 17 , 26 67 13 12 M8X1.25 7 M18X1.5 63 600 20-600 18 15 M10X1 .25 7 M18X 1.5 37 40 102 129 V V 78 25 52
Selection Graph (2)-1 Pad Diameter Selection Graph by Lifting Force Vertical Lifting (2 to 50) Selection Graph (1)-1 Pad Diameter Selection Graph by Lifting Force Horizontal Lifting (2 to 50) 50 40 32 25 20 16 13 10 8 50 40 32 25 20 16 13 10 8 -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa Pad diameter (mm) Pad diameter (mm) Pad diameter (mm) 6 6 4 4 2 2 Lifting
st or more 15 to 49 st 50 st or more 10 st or more 15 to 49 st 50 st or more D-H7/H7W D-H7BAL/H7NF 10 st or more 15 to 59 st 60 st or more 10 st or more 15 to 59 st 60 st or more D-C73C/C80C/H7C 10 st or more 15 to 64 st 15 to 74 st 65 st or more 10 st or more 15 to 64 st 15 to 74 st 65 st or more D-B5/B64/G5NTL 10 st or more 15 st or more 75 st or more 75 st or more 10 st or more 75 st
Body Ported Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series MB/CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation SX3120-C6 0 800 700 600 500 400 300 200 100
VAC (50/60 Hz) Single phase 85 to 132 VAC 0.4 Control power supply Allowable voltage range for control power supply [V] Rated voltage [A] Parallel input Parallel output Max. input pulse frequency [pps] 10 inputs 6 outputs 1 M (when differential receiver), 200 k (when open collector) 0 to 10 (Pulse command unit) 3 rotations Parameter setup or external analog input setup (0 to 10 VDC) USB
50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1 5 10 20 50 1 5 10 20 50 8 For Air Digital Flow Switch/High Flow Rate Type Series PF2A Refer to www.poweraire.com for details of products compatible with overseas standards.
2-DR CZ 2-CR DH CH DI CI DE DF CE CF DL CL DA DB CA CB CDH10 (mm) DDH10 (mm) CJ 7 10 10 14 CI 17 22 27 32 CH 11 13 13 17 CF 4 7 10 12 CE 3.5 3.5 3.5 5.5 CB 23 27 31 37 CA 53 67 85 103 DJ 7 10 10 14 DI 17 22 27 32 DH 11 13 13 17 DF 4 7 10 12 DE 3.5 3.5 3.5 5.5 DB 23 27 31 37 DA 53 67 85 103 Size 25 32 40 50 Size 25 32 40 50 Part no.
/60Hz) Allowable voltage range 10%(No continuous voltage fluctuation) Electrical system Power supply 3-phase 460 to 480 VAC(60Hz) Allowable voltage range +4%/-10% (Maximam voltage is 500V and no continuous voltage fluctuation) Applicable Earth Rated current A 20 leakage breaker(note7) Sensitivity of leak current mA 30 Rated operating current 50/60Hz A 6.8/8.2 Rated power consumption 50/60Hz
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
Fittings & Tubing Air Cylinders Rotary Actuators 1021-VV5Q21 (n-1) x 16 L1 L5 = 16n + 108 L6 = L3 + 25 L7 = L4 + 25 L11 = L4 + 50 L10 = L3 + 50 L9 = 16n + 131 82 34.5 1 SERIAL UNIT x 1 x 10 STATION NO.
Fittings & Tubing Air Cylinders Rotary Actuators 1021-VV5Q21 (n-1) x 16 L1 L5 = 16n + 108 L6 = L3 + 25 L7 = L4 + 25 L11 = L4 + 50 L10 = L3 + 50 L9 = 16n + 131 82 34.5 1 SERIAL UNIT x 1 x 10 STATION NO.
(HRSH100-A-20/40-, HRSH100-W-20/40-) 8.5.2 HRSH150/200-A-20/40HRSH150/200/250-W-20/400.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Circulating fluid flow [L/min] Fig. 8-17: Pump capacity (HRSH150/200-A-20/40-HRSH150/200/250-W-20/40-) 8.5 Pump
Allowable Moment of Inertia (32, 40) 10-1 New MK series Current MK series Current MK2 series Allowable moment of inertia [kgm2] New MK series (Standard) 10-2 Current MK2 series (Heavy-duty type) 10-3 Current MK series Overall Length Dimensions Standard arm Bore size Shortened dimensions (compared to the current MK2 series) 20 25 32 40 50 63 MK series overall length (at 20st) 10-4 50 100 200
I-B DA DB DL lou number II:, Imm) IDe OX D E DO (>"UN 'u, O S DH Z DDH9-: 32 164 10"" 36 18' 12 ' 45 202 ". . . , 46 31 21 18 5 38 26 51 6.5 6.6 11 7 41 28 54 6.5 6.6 11 9 ' 50 32 65 7.5 9 15 11 52 35 24 22 5.5 65 45 33 30 6 50 222 16' '" 52 40 67 7.5 9 15 11 66 50 86 10 11 16 12.5 ' 75 50 37 35 6.5 95 60 47 40 6,5 63 250 16 ' ." 76 60 96 10 11 18 1 3 5 71 70 20 114 70 55 50 7.5 ~, Rotating
(mm) Port size Av x 10-6m2 Cv converted 10 10 15 10 15 20 25 35 40 50 1/4 (8A) 1.9 2.4 4.5 2.4 5.5 9.5 13 23 31 49 46 58 110 58 130 230 310 550 740 1200 VXED2130-02 VXED2130-03 VXED2140-03 VXED2130-04 VXED2140-04 VXED2150-06 VXED2260-10 VXED2270-32 VXED2380-40 VXED2390-50 420 0.5 3/8 (10A) 670 500 670 1150 1650 5400 6800 8400 1.0 0.5 Thread (Nominal size) 0.02 1/2 (15A) 1.5 3/4 (20A) 1 (25A
6 7 20 25 80 37.5 55.5 6 7 20 25 80 50.2 78.2 10 7 20 38.5 110 60 88 10 7 20 38.5 110 Multi-turn type (with indicator) Valve closing direction Valve opening direction Y (mm) Dimensions (Max.S) S 89.6 Y 50 Model LVQH20-Tm-4 LVQH30-Tm-4 LVQH40-Tm-4 LVQH50-Tm-4 LVQH60-Tm-4 107.2 50 112.7 50 A B 165 71 174.5 71 580 Air Operated Type for Back Pressure 0.5 MPa Integral Fitting Type (Hyper Fittings
5.8 28 5.5 10 CY1SG25-Z M6 x 1 M6 x 1 10 11 26.4 52 8.5 70 40.5 40.5 27.5 21.5 21 12.5 22 17 6.5 16 2 5.5 8 54 53 20 70 49 7.5 7 10 CYP CY1SG32-Z M8 x 1.25 M8 x 1.25 12.5 14 33.6 64 9.5 86 50 50 33 26 24 11.5 23.5 17.5 8.6 20 5.5 66 64 26 52 2 9 85 9 5.5 12 CY1SG40-Z M8 x 1.25 M8 x 1.25 12.5 14 41.6 74 10.5 104 55.5 55.5 38 27 27 10.5 22.5 16.5 8.6 25 5.5 76 74 28 51 2 10 95 4.5 9 12 Bumper
Series Variations Model Bearing Bore size Stroke [mm] Cushion Piston speed Port size Mounting direction JMGP 12 (10 x 2) 10, 20, 30, 50, 100 M3 x 0.5 16 (12 x 2) 20 (16 x 2) 20, 30, 50, 100, 150 M5 x 0.8 25 (20 x 2) 50 to 300 mm/s Top 32 (25 x 2) Rubber bumper on both ends Slide bearing Bottom 40 (32 x 2) 1/8 (Rc, NPT, G) 50 (40 x 2) Rear 25, 50, 100, 150, 200 63 (45 x 2) 80 (56 x 2) 50 to