DC (+) 1 NC 2 DC () 3 4 OUT 4 43 2-3.4 Flow direction PFA511/521/551 62 116 23 1.6 76.2 54 44 34 44.5 2-Port size 30 40 50 (43.5) 42 6 Flow direction 9 Series PFA Dimensions/Remote Type Display Unit for Air PFA3-A Panel mount type Internal circuit and wiring examples to are terminal numbers. 41.8 40.3 Sensor 4.3 40 Blue Brown Black N.C. 1 2 3 4 SMC FLOW SWITCH 5 6 7 8 OUT1 OUT2 35.8 A 40

250 0 0 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-308 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.7 MPa ARM5AA1-308-1 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.5 MPa 0.7 0.35 0.6 0.30 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0 50 100 150 200 250 0 0 50 100 150 200 250 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-309 (One-touch

size Lubrication Model Rubber Air M3 x 0.5 12-CY3B6 6 300 50, 100, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250

Detection nozzle: 1.5 Detection nozzle piping: F type 4 x 2.5 tube 1 m, 3 m, 5 m/G, H type 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa Test conditions ISA3-F ISA3-G 300 60 3 m 1 m 250 50 5 m 1 m 5 m Displayed value Displayed value 200 40 3 m 150 30 100 20 50 10 0 0 0.3 0.25 0.2 0.15 0.1 0.05 0 0.06 0.05 0.04 0.03 0.02 0.01 0 Actual distance [mm] Actual distance [mm] ISA3-H 500 450 3

Made to Order (Refer to page 549 for details.) 548 Series AS-FG Speed Controller with One-touch Fitting Stainless Steel Series In-line Type How to Order AS 200 1 F G 06 Lock nut option Nil J Hexagon lock nut Round lock nut Body size 100 200 205 300 400 AS M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Made to Order (Refer to the below for details.)

How to Order 1F 06 T 200 AS Flow Direction Symbols on Body Indication symbol Symbol Body size Tamper proof Note) Speed controller requires a special tool for flow adjustment. Order separately with part number, AS-T-1. 100 200 205 300 400 M5 standard 1/8 standard 1/4 standard 3/8 standard Made to Order (Refer to page 608 for details.) Applicable tubing O.D.

A: Non-locking extended type 4 Valve size 1 to 4 6A 8A 10A 1 8 1 4 3 8 5 6 24 VDC 12 VDC 1 7 B: Locking slotted type 7 240 VAC 50/60 Hz 9 Other 11 15 11 10A 3 8 Option 2 15A 1 2 15 14 3 20 16 Nil: Non-locking push type 20A 3 4 Valve size 5 to 7 25 4 25A 1 22 11 4 32A 5 32 Electrical entry/ With light/surge voltage suppressor 1 B 22 32 28 40 6 28 40 1 4 32F Flange 11 2 40A GS Grommet

Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 125mm, First Stroke: 70mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)

Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 125mm, First Stroke: 50mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25/10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Both

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Both

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50/30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Both

Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 190mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 3 pcs.

Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 100mm, First Stroke: 10mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 3 pcs.

Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 25mm, First Stroke: 20mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25/10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Both

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Both

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50/30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Both

Mounting: Both Ends Tapped, Bore Size: 63mm, Thread: Rc, Full Stroke: 150mm, First Stroke: 140mm, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Mounting: Both Ends Tapped, Bore Size: 63mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 190mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 3 pcs.