(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state) Caution Be sure to read before handling.
(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state) VFRA VPA4 SYJA Caution VZA Be sure to read this before handling the products.
left direction IN Symbol Series Orifice diameter (mm ) IN 1 3 4 6 1.0 3.0 4.5 6.0 30 L1 Nil 40 OUT OUT Quick Fastener Clip Part No. 90 left direction 45 right direction Series Size Quick fastener clip part no. (2 pcs.)
psi 3 150 psi G Compensation spring (A) For IP6000, 6100 X15 Intrinsically safe Non-incendive IP6000, 6100 X15N Same, with Namur feedback shaft IP6100 1/6 1/6 Construction 0 No terminal box X83 Analog output potentiometer IP6100 1 With terminal box For IEC rating IP6100 X165 Same, with Namur feedback shaft 1/6 EXTERNAL FEEDBACK LEVER The feedback lever is selected according to valve stroke
Since Q0 = 15/45 = 0.33 [ /min], according to the Graph (2), if reading P when Q0 is 0.33, it will be 0.031 [MPa]. Example 2) Obtain the flow rate of saturated aqueous vapor when P1 = 0.8 [MPa], P = 0.008 [MPa] with a solenoid valve with an Av =1.5 x 106 [m2]. According to the Graph (2), if reading Q0 when P1 is 0.8 and P is 0.008, it is 0.7 [kg/h].
specifications 10% of rated voltage Allowable voltage fluctuation VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil insulation type Class H Power consumption (W) 50/60 Hz VCB2: 4.9/4.1, VCB3: 7.7/6.6, VCB4: 10.5/9.3 VX3 Inrush VCB2: 22/19, VCB3: 36/30, VCB4: 45
Base mounted (With sub-plate) 75 (Without sub-plate 45) Rc(PT)1 /8 4.5 (0.25) SYJA524-01 N.O. SYJA712-01 N.C. Rc(PT)1 /8 9 (0.5) 80 Body ported SYJA722-01 N.O. Base mounted M5 X 0.8 Rc(PT) 1 /8, 1 /4 01 02 01 02 SYJA714N.C. Base mounted (With sub-plate) 130 (Without sub-plate 80) SYJA724N.O.
material CAC406 (BC6), SUS Valve specifications Coil Specifications Seal material FKM, EPDM Ambient temperature C 20 to 100 Fluid temperature C 99 or less Enclosure Dust proof, Splash proof (equivalent to IP65) Environment Location without corrosive or explosive gases Valve leakage cm/min 0 (with water pressure) Mounting orientation Unrestricted Vibration/Impact resistance m/s Note 1) 30/150
TYPE Class Instance Attribute Size Description Output 100 100 3 1 INT Position set-point Input 150 150 3 2 INT 2 bytes measured position, 2 bytes diagnostics Figure 16-1 Explicit Messaging 41 - IN20267 Installation and Handling 17. Air supply 17.1. Use clean air.
(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.
Only air, N2, are applicable. [6000] 6000 L/min (PF3A712H) [F 1] [ 150] 150 L/min (PF3A703H) The accumulated flow has exceeded the accumulated flow range. (For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
/40 200/50 / AC200V 800/40 800/50 XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 1 1 1 H5 AC100V 200/40 400/70 400/80 / AC200V 800/40 1600/80 1600/80 XLA-63-2 XLA-80-2 AC90240V XL1A25-60S-2 XL1A25-60S-3 1 1 H4 AC100V 400/100 600/150 / AC200V 1600/100 2400/150 XL1A25-60S-3 XL1A25-60S-2 1 2 H5 AC100V 600/130 800/180 / AC200V 2400/130 3200/180 1[W] 216 PTC 200V PTC 200 150
800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 Ass'y XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 Ass'y 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1)/ 2)16 PTC() 200V 200 PTC 150 100V PTC Ass'y 0 5 10 15 20 25 30 Ass'y ( Ass'y 30 8 XL-OMV0002 4 4-1.162540 Assy SUS304 SUS316L ( SUS304) ( A6063) C D C E E (KF ) Fn J H B A G A mm A B C
800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12 ( SUS304 M 3 M SUSU316L 8 11 SUS304 2 7 A6063 6 9 6 9 10 9 5 SUS304 4 5 10 4 10 S O S O XLD-25 XLD-40,XLD-
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF.
Modification method Ordering method Refer to standard part numbers and ordering. 5 to 350 Applicable stroke (mm) Model: MLGPM40-45-B A 5mm spacer is installed in MLGPM40-50-B Ordering example Note) The minimum stroke for mounting auto switches is 10mm or more for 2 pcs., and 5mm or more for 1pc. 3 Series MLGP Dimensions 40 to 63/MLGPM, MLGPL/Extension locking (mm) LOCK 1in = 25.4mm T-slot
Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
See LECSC Operation Manual , section 6.4 for details. -45- 5.6 Positioning Mode in Setup Software From the Test Mode menu of the Setup Software select Positioning Mode. The Move Distance Unit Selection window opens. Click OK. (When using this function, external input signal operation will be disabled.
Refer to the Card Motor specifications for details. 45 - 11.2 Positioning operation The "positioning" is registered in [Step data] [Operation], the positioning operation is executed. Travels to the target position set by [Step data] [Target position].