F9PSDPC CXT Direct Body Mount 12, 16, 20, 25, 32 & 40 Bore sizes MHK, MHKL Direct Body Mount 12, 16, 20 & 25 Gripper Bore sizes MHS2/3/4 Direct Body Mount 16, 20 & 25 Gripper Bore sizes MHQ2-6 Direct Body Mount 6 mm Gripper Bore size MHR2/3 Direct Body Mount 10, 15, 20 & 30 Gripper Bore sizes (bore sizes depend on series) MHY2 Direct Body Mount 10, 16, 20 & 25 Gripper Bore sizes MHZ2 Direct
Inch Bottom bracket Single sided connections IRV 20 A C08 Made to Order For details, refer to page 10.
10-S005 FN41l2l-20-S005 20 m FN11lll-10-S020 FN41l2l-20-S020 100 100 80 80 Filtration efficiency (%) Filtration efficiency (%) 60 60 40 40 20 20 0 0 10 5 20 50 75 25 20 35 65 90 Particle diameter (m) Particle diameter (m) 3 Low Maintenance Filter Series FN1/FN4 Blocking Characteristics (Repeatability) P Fluid: Potable water P Supply pressure: 0.2 MPa P Flow rate: 20 l/min P Test dust: AC
106 120 17 20 The minimum stroke with rod boot is 30 mm or more.
) (20) (20) 0 0 0 0 0.05 (1.5) 0 0.11 (3) 0.16 (4.5) 0.21 (6) 14.5 (0.1) 29 (0.2)43.5 (0.3) 58 (0.4)72.5 (0.5) 87 (0.6) Supply pressure psi (MPa) Suction flow SCFM (L/min (ANR)) K Nozzle Size 0.6 mm Supply Valve, Large Flow Type (N.C.)
For Saturated Steam (664)(183) Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) [MPa] (663)(179) 0.8 (662)(174) (661)(170) Subsonic Critical pressure 0.9 0.6 (660)(164) 0.7 0.8 (658)(158) Sonic 0.4 0.6 (656)(151) 0.5 (654)(143) 0.4 (650)(133) 0.2 0.3 0.2 (646)(120) 0 0.1 2 5 10 15 25 20 3 10 15 20 25 45 40 35 30 4 20 10 30 40 50 60 5 30 40 50 60 70 80 20 7 20 30
") 0.75 0.78 0.50 1/8 7/16-20 0.75 0.63 1.75 5.75 50 (2.00") 0.75 0.78 0.50 1/4 7/16-20 0.75 0.63 1.75 5.75 63 (2.50") 0.75 0.78 0.50 1/4 7/16-20 0.75 0.63 1.75 5.88 80 (3.25") 1.13 1.28 0.75 3/8 3/4-16 1.25 0.94 2.50 7.50 100 (4.00") 1.13 1.28 0.75 1/2 3/4-16 1.25 0.94 2.50 7.50 3 Series CG5 Single Rear Clevis Mounting Type CG5E (MP3 Mounting Style) LR 2-EE NPT MR KK CD A XC + STROKE EW
Tel :03-3502-2740 Fax:03-5251-7240 August 1996, 14(RP)
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2012 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in XXX. D-DN
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
(Displays 0 when the value is (Displays 0 when the value is below 10 L/min) below 20 L/min) 20 to 1050 L/min 40 to 2100 L/min 2.0 0 to 2%F.S. (Displays 0 when the value is (Displays 0 when the value is below 20 L/min) below 40 L/min) 30 to 1050 L/min 60 to 2100 L/min 3.0 0 to 3%F.S.
(See Appendix 8.4 Offset Function in Chapter 8 for details.) 4 OFFSET OFF, MODE1, MODE2, MODE3 HRZ-L: -20 to 45C HRZ-L2 : 10 to 45C HRZ-H: 20 to 93C HRZ-W: -20 to 93C Issues an alarm of Reservoir High Temp WRN if the circulating fluid exceeds the set temperature. 5 HIGH TEMP Issues an alarm of Return Low Flow WRN if the circulating fluid does not reach the set flow rate.
B(9.5) B(12.7) B(19.1) 1B(25.4) 1 B(31.8) 1 B(38.1) 2B(50.8) VNA 111 211 311 411 511 611 711 AS 420-03 420-04 500-06 600-10 800-12 900-14 900-20 Caution Warning 1Piping When operation is suspended, surge pressure will be generated between the cylinder and VNA11A.
20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 , , 1 4 3 8 40 40 50 50 55 55 65 85 , AMH250 1 2 3 8 1 2 , AMH350 3 4 1 2 3 4 , AMH450 1 1 1 1 AMH550 AMH650 3 4 1 2 , , 14-20-34 6 Micro Mist Separator with Prefilter Series AMH AMH850 Dimensions Accessory D: With auto-drain (N.O.) for AMD850 female thread Option T: With element service indicator Courtesy of Steven Engineering, Inc.
22 8.5 R7 22 20 NAAMS code K NAAMS code K Part no.
F Bracket VK300-43-1A 20 stations 20 Port P: Rc(PT) 1/8 Port R: Rc(PT) 1/8 Common SUP, Individual EXH Type 21/for body ported type (Port A top ported) How to Order Applicable solenoid valves VKF333--M5 VKF333--01 VV3KF3-21 05 Port A: Rc(PT) 1/8, M5 x 0.8 Valve stations Applicable blanking plate assembly VK300-42-1A 01 1 station 20 20 stations Port P: Rc(PT) 1/8 Port R: Rc(PT) 1/8 Base
15 63 70 183 79 2 11 75 52 20 17.5 68 88 217 100 3 11 87 95 70 20 20 72 90 256 117 3 11 114 110 83 20 26.5 98 108 321 154 3 11 134 130 102 20 38 133 138 335 200 3 11 190 180 153 30 40 114 Note 1) Dimension E applies when heater option is included.
Made to Order Specifications (For details, refer to page 14-20-55.) 01 B 06 B 1 8 3 4 1B 02 03 10 14 B 1 4 B 3 8 04 B 1 2 Note) Refer to How to Order Bowl Assembly on page 14-20-59. 1 B 1 2 20 2B Caution Accessory/Option Combinations Available Not available Depends on model Be sure to read before handling.
160 180 200 220 240 260 Operating temperature (oC) Inch size 20 TILM01 N Max. operating pressure (MPa) 1.2 D 1.0 Tubing designation Length per roll Symbol 10 20 50 100 16 33 2S 0.8 Type Length 10 m 20 m 50 m 100 m 16 m (50 ft) 33 m (100 ft) 2 m 0.6 Color indication F Symbol N R BU B Color Translucent Red (Translucent) Blue (Translucent) Black (Opaque) 0.4 Roll G 0.2 Straight 0.0 20 0 20
P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N