B B B A A A A A A A A Model A B C D E Fn G H J K XLC-25 50 120 48 1 12 40 26 39 27.5 8 XLC-40 65 171 66 2 11 55 41 63 36 9 8 XL-OMO0001-A 5 Guaranteed period and range The warranty period is 2 million cycles (under SMC endurance test conditions), 18 months after delivery or 12 months in service, whichever comes first.
(extension) A B Air pressure supplied from B operates on surface 3. (retraction) A B Mounting accuracy improved Positioning holes are provided on the work piece mounting surface for easy alignment.
Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.
AS-FE 1/8 0.07 1/4 0.16 KE 3/8 0.2 1/2 0.4 AS-FG When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. AS-FP AS-FM 4.
AS-FE 1/8 0.07 1/4 0.16 KE 3/8 0.2 1/2 0.4 AS-FG When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. AS-FP AS-FM 4.
The port on the piston rod B side for 10-/12-, 21is plugged since unlike the vacuum, it is not necessary to exhaust from 2 ports.
ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Model Model Model Port size R(PT) Effective area (mm2) Weight (g) Dimensions (mm) Weight Effective area Port size Model Dimensions (mm) R(PT) (mm2) (g) AN200-02 35 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233 74 60 820 263 86 70 A B D A B D 1 4 1 4 AN202-02 35 16 64 22 19 33 84 28 24 47 95 34 24 AN300-03 60 3 8 AN302-03 60 3 8 AN402-04 90 1 2 AN400
Model Weight Weight (g) VFN2000N/Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN2120N-5D-02F 260 400 C 3.48 3.48 b 0.25 0.25 Cv 0.85 0.85 C 4.57 4.57 b 0.17 0.17 Cv 1.06 1.06 VFN2220N-5D-02F 2 position Single solenoid Double solenoid How to Order VFN2 20 1 5 D N 02 F Z Thread type Solenoid Single solenoid Double solenoid 1 2 NAMUR Interface Rc (PT) G (PF
Model Weight Weight (g) VFN2000N/Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN2120N-5D-02F 260 C 3.48 3.48 b 0.25 0.25 Cv 0.85 0.85 C 4.57 4.57 b 0.17 0.17 Cv 1.06 1.06 VFN2220N-5D-02F 400 2 position Single solenoid Double solenoid How to Order VFN2 20 1 5 D N 02 F Z Thread type Solenoid Single solenoid Double solenoid 1 2 NAMUR Interface Rc (PT) G (PF
When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off.
When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off.
[ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 W 5.5 0 0 2.5 W 7.5 2.0 2.0 0.5 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 A 16.5 15.0 22.0
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
Turns on: COM B is receiving data. Turns off: COM B has no received data. Turns on: COM A is receiving data. Turns off: COM A has no received data. Turns on: PROFIBUS DP communication is abnormal. Turns off: PROFIBUS DP communication is normal. Turns on: Power is supplied to solenoid valves/output at specified voltage.
Then the pressure in the pressure action chamber B falls to open the main valve C. < Valve closed > When the coil o is not energized, the pilot valve A is closed and the pressure in the pressure action chamber B rises and the main valve C closes.
AS-FE 1/8 0.07 1/4 0.16 KE 3/8 0.2 1/2 0.4 AS-FG When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. AS-FP AS-FM 4.
x 1.5 14.5 x 10.5 x 2 Bracket A 2 Bracket KA00078 KA00083 2 1 set assembly Bracket B O-ring 136312 136412 NBR 7 13 JIS B 2401 P3 JIS B 2401 P5 Hex. socket head cap screw 2 KA00299 KA00961 O-ring NBR 8 How to order (1) When adding n stations to ARM Regulator n pcs.
(Part1:General requirements) ISO 10218-1992:Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1:-((1 :) JIS B 8433-1993: 2) : : : 1 2. 3. 1. 2. 3. 4. 2 No.LFE*-OMY0008 / 1 1.5 3 3) 1 1 () [] 3 No.LFE*-OMY0008 () () () () 4 No.LFE*-OMY0008 () * (100 20 ) () <> 2MPa 5 No.LFE*-OMY0008 * (1623 ) FG (49N ) () M12 IN IN OUT OUT OUT OUT () 6 No.LFE