0.01 s step Enclosure IP65 Environment Withstand voltage 250 VAC for 1 minute between terminals and housing Insulation resistance 2 M or more between terminals and housing (with 50 VDC megger) Ambient temperature range Operation: -5 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Operating humidity range Operation, Storage: 35 to 85%RH (No condensation) Standard CE/UKCA marked
None CHQ CHK CHN Ambient and fluid temperature Piston speed Cushion CHM CHM +1.0 0 to 250 mm 250 to 800 mm +1.4 0 CHS Stroke length tolerance CH2 Basic type, Axial foot type Head flange type, Rod flange type Single clevis type Mounting type CHA Note) Refer to page 214 for definitions of terms related to pressure.
(rad/s) : Rotation angle.(rad) 180 = 3.14rad t: Rotation time.
GR-S-005 (5g) GR-S-010 (10g) GR-S-020 (20g) GR-S-005 (5g) GR-S-010 (10g) GR-S-020 (20g) GR-S-005 (5g) GR-S-010 (10g) GR-S-010 (10g), GR-S-020 (20g) (1 pack each) Order one finger assembly and pinion assembly per unit. For piston assembly and rack, order 2 pieces per unit. For rod cover assembly, order 4 pieces per unit.
2 Thread type Symbol With light Surge voltage suppressor Common specification R r Pilot type Nil Rc F G N NPT T NPTF Nil Internal pilot R External pilot Non-polar U V S Positive common Z V NS Negative common NZ V V * Only Nil is available for M5. t Back pressure check valve Nil None H Built-in * Select a valve from R, U, S or Z when the SI Unit output polarity is positive common.
TDe8 TR W W D D E E d d TY M a MA MA M a C K F NA F NA A K A B H S + Stroke H + Stroke 0 -0.5 TX ZZ + 2 strokes TZ (mm) Bore size (mm) E H TR A a B C d F G GA J K M MA MM NA P R S T D TDe8 0 -0.018 0 -0.021 0 -0.021 0 -0.021 0 -0.025 0 -0.025 0 -0.025 -0.032 -0.059 -0.032 -0.059 -0.032 -0.059 -0.040 -0.073 -0.050 -0.089 -0.050 -0.089 -0.050 -0.089 0 -0.062 0 -0.062 0 -0.074 0 -0.074 0 -0.074
The piston speed may exceed the maximum operating speed of 500mm/s if the piping is directly connected to the cylinder. Please use speed controllers by SMC to adjust the piston speed so that it will not exceed 500mm/s.
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
If the adjusting screw of the speed controller is loosened, the operating speed will increase, so the screw should be tightened completely. m Impact force MXZ12 MXZ16 1.4 2.5 V = mm/s V = mm/s 1.2 2.0 Load weight m [kg] Load weight m [kg] 1.0 1.5 0.8 0.6 1.0 V = 50 V = 50 0.4 V = 100 V = 100 V = 200 V = 200 0.5 V = 500 V = 500 0.2 0.0 0.0 60 50 40 30 20 10 0 0 5 20 15 10 25 30 35 40 45 50
Use a fluid with a kinematic viscosity of 50 mm2/s or less.
The moving speed of the first operation after the recovery is 50mm/s. 38
For AC voltage valves there is no S option. It is already built-in to the rectifier circuit. 3 position closed center With light/surge voltage suppressor (Non-polar type) 3 position exhaust center For AC voltage valves there is no S option. It is already built-in to the rectifier circuit. For type R and U, DC voltage is only available.
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Turn power off and then on again. 1.6 Over current 500 ms 500 ms 0 1.0 5.0 1.3 1.2 Input signal Voltage [V] Flashing: Two ashing cycles of 250 ms at two-second intervals Error automatically resets when the supply ow rate is recovered (LED goes off). Insufcient supply ow rate Flow rate control Position control (Fully closed) 250 ms 250 ms 2000 ms 1 A
Low Maintenance Filter Series FN1/FN4 How to Order 0 1 N S 020 With single element FN11 10 0 2 N S 020 With four elements FN41 20 Pressure gauge Housing material Symbol Pressure gauge Symbol Housing material Nil G Note 1) None (With plug) 1 Stainless steel 304 With pressure gauge Note 2) (Wetted part: Brass) Note 1) Contact SMC for the pressure gauge specification for stainless steel wetted
Settings1 Content 3 4 OFF OFF 1 Mbps (Default setting) OFF ON 500 kbps ON OFF 250 kbps ON ON 125 kbps : This function is for possible extension. Keep the default setting of 1 Mbps. -22No.EX-OMN0030-D Diagnostics switch: Allocates the diagnostic data to the input data.
View port G1/2 5 10 30 50 100 300 Flow rate (L/min) Conditions Fluid: Turbine oil Class 2 VG56 Measured pressure: 14 MPa Viscosity: 45 mm2/s Filter material: Paper Nominal filtration: 10 m FH64 Series Refer to page 529 for Microswitch for differential pressure indication switch. 16 0.1 10/12 0.05 0.04 0.03 06/08 Pressure drop (MPa) 0.02 03/04 0.01 0.005 0.003 5 10 30 50 100 300 Flow rate
P Panel mount union U Union Ordering Example OUT side Tube size 4 x 3 LQ1U22-S Union SMC PB1313AS-1S07 Process pump PB1313AS-1S07 1 LQ1E21-S (Union elbow) 1 LQ1U22-S (Union) 1 LQ1E21-S Union elbow Tube size 6 x 4 Note) Fittings ordered together with the process pump will be shipped in a separate package.
Data L R S Piping Port Locaition Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model. Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.