SMC Corporation of America
Elite Part Number Search
Search Results "KRM12-08-03-6"

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, PILOT CHECK VALVE: METAL BODY TYPE, FLOW CONTROL, 60 lb

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, FX, AS 1/2INCH (MISC./OTHER), .36861 lb

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, SPEED CONTROLLER, FLOW CONTROL, SVD, 150.00000 lb

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, FX, AS***F 1/2INCH(MISC./OTHER), .33660 lb

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, FX, AS***F 1/2INCH(MISC./OTHER), .32340 lb

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, SPL, FLOW CONTROL, SVD, 20.00000 lb

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Speed controller with one-touch fittings; Body sizes: M5, 01, 02, 03, 04; Metal body elbow style; Meter-in or meter-out control; Port sizes: M5, 01, 02, 03, 04; Tube O.D.: 04, 06, 08, 10, 12

IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Recommended air flow Tubing size Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Unrestricted 360 piping tube mounting. The connector for the IN side is a universal joint type that enables a tube to be connected in any direction within 360.

Contact protection box OUT() Brown(Red) 12 10 8 15 16 9 12 6 6 20 25 32 40 50 63 80 100 125 140 160 Reed switch 13 CDJ2, CDVJ CDQ2 to 10 12 6 6 6 6 12 12 6 6 6 6 12 13 12 6 6 6 6 12 13 12 12 12 11 10 12 12 13 13 13 CD-P11 CD-P12 OUT( ) Blue(Black) B P CDXW 6 6 6 CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT 6 6 6 6 6 6 11 13 11 11 11 Note) qIn the case operation load is an inductive load. wIn the

6 r e w !4 o !5 u !0 #4 #3 $7 #7 @4 q i @8 $6 @7 $2 @0 $8 #8 $5 $0 #0 #1 @6 @2 $4 #9 @9 $6 @1 $2 @5 !3 $3 !9 $1 #5 #2 !2 #6 A @3 A Section A-A !7 !8 t !7 Enlarged drawing of shim part !6 y !

Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 Although speed adjustment is possible with