SMC Corporation of America
Elite Part Number Search
Search Results "KNS-R01-100-4"

[particles/m3] Particle concentration [particles/m3] Suction flow rate: 30 L/min ISO Class 5 upper limit 10 10 ISO Class 5 upper limit 1000 1000 Suction flow rate: 30 L/min Suction flow rate: 60 L/min ISO Class 4 upper limit 100 100 Suction flow rate: 50 L/min ISO Class 4 upper limit 10 10 1 1 0 0.1 0.6 0.5 0.4 0.3 0.2 0 0.1 0.6 0.5 0.4 0.3 0.2 Particle diameter [m] Particle diameter [m]

pressure 0.1 0.3 MPa 2 x Rc 1/4, NPT 1/4 HAA HAW 0.1 MPa Max. flow rate line B Pressure drop MPa AT IN 0.01 IDF IDU 0.7 MPa 0.5 MPa IDF FS A 0.001 IDFA A B Model Connection Rc 1/4 NPT 1/4 Rc 1/4 NPT 1/4 Rc 1/4 NPT 1/4 SFA100-02 SFA101-02 SFA200-02 SFA201-02 SFA300-02 SFA301-02 46 76 IDFB 51 96 IDH 0.0001 1000 1 10 100 59 120 ID Flow rate L/min (ANR) IDG SFA20 SFA102, SFA202, SFA302 IDK 0.1

Enable Val165000 4 ON 8 ON/OFF 3 Disable ON/OFF 0 83 9 ON/OFF Auto 10 HDX 10 BUS IN BUS IN 10 FDX 100 HDX 100 FDX Auto 10 HDX 11 BUS OUT BUS OUT 10 FDX 100 HDX 100 FDX 1Hold/Clear Via software 2PLC 330 4x1000 -44No.EX-OMS0026CN No.

50 33 5 to 50 46.5 29.5 40 Rc1/8 NPT1/8 NPT1/8 G1/8 8 11 G1/8 Rc1/8 NPT1/8 NPT1/8 56.5 39.5 8 11 52 50 41.4 75, 100 56.5 39.5 10 to 50 50.5 30.5 50 10.5 10.5 G1/4 Rc1/4 NPT1/4 NPT1/4 60.5 40.5 10.5 10.5 64 62 53.4 Rc1/4 NPT1/4 NPT1/4 G1/4 75, 100 60.5 40.5 HA NN NN OA Bore size (mm) 32 40 50 V W HB IA IB J KA KB L M N OB RA RB S U Z , TN, TF , TN, TF 38 10 5 60 58.5 4.5 28 19.8 7 34 5.5

SY11 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0 0.22 100 kPA to 0.6 Large flow 0 to 0.7 N.C. SY13(A): 15 SY14(A): 26 (14) SY13(A): 13 SY14(A): 24 (12) (1) SY12 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 0.14 100 kPA to 0 Standard 0 to 0.7 N.O. (1) SY12 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 100 kPA to 0 0.22 Large flow 0 to 0.7 N.O.

Both Ends Tapped [mm] Bore size O1 R 50 M6 x 1.0 10 63 M6 x 1.0 10 80 M10 x 1.5 18 100 M10 x 1.5 18 Auto switch Minimum lead wire bending radius 10 F Q 2 x P (Rc, NPT, G) (Port size) 4 x N through H thread effective depth C I D M E Z A + Stroke B + Stroke L W E M K J 2 x P (Rc, NPT, G) (Port size) 100 Auto switch Minimum lead wire bending radius 10 H thread effective depth C 4 x N through

ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250

mm LX X X LG Y Y Bore size (mm) 4-LD LS + Stroke A + Stroke LG LH LX LY LZ X Y 3.2 LZ 32 4 57 57 11.2 30 71 5.8 40 4 64 64 11.2 33 78 7 Rod end male threads 50 5 79 78 14.7 39 95 8 Rod end nut L1 Front flange type mm Front flange type/RQF, RDQF Bore size (mm) Stroke range (mm) A B FD FT FV 20 to 100 32 37 5.5 8 48 54 20 to 100 40 M FV 44 5.5 8 54 61 30 to 100 50 49.5 6.6 9 67 67.5 mm 4-FD

Duty rrtb = (t + 1 + 0,8)/ (1 + 0.9 + 1 + 0,8+10 X 100 = 50% ..Possible to us, @ Operation Sloppage Figure 2 Duty ratio: (4 + 3)/ (4 +0,2+3 +2DX 100 = 75% '.Not possiblc to use, Senies Ufi tleilnic Artuilo lfifiBli[ It|onoil lllMmce Table receives moment from each direction accordino to cenler of gravity ot work. Overhang ot work should be within the range shown in the figures below.

during workpiece transfer. 0 20 40 60 80 100 0 20 40 60 80 100 Gripping point L mm Gripping point L mm 12-11-8 9 Rotary Gripper Series MRHQ External Gripping Force/Single Acting Internal Gripping Force/Single Acting MRHQ10S MRHQ10C 12 Pressure 0.7MPa Pressure 0.7MPa 20 10 MHZ 0.6 MPa 0.6MPa Gripping force N Gripping force N 8 15 MHF 0.5MPa 0.5MPa 6 10 0.4MPa 0.35MPa MHL 0.4MPa 0.35MPa 4

Gripping point L mm Gripping point L mm MRHQ25 MRHQ25 120 100 Pressure 0.2MPa 100 Note: 1in = 25.4mm 1MPa = 145psi 80 Pressure 0.2MPa 80 Overhang H mm Overhang H mm 60 0.3MPa 0.5MPa 0.6MPa 0.7MPa 60 0.7MPa 0.4MPa 0.3MPa 0.4MPa 40 0.5MPa 40 0.6MPa 20 20 0 20 40 60 80 100 0 20 40 60 80 100 120 Gripping point L mm Gripping point L mm 4 Rotary Gripper Series MRHQ Effective Gripping Force Effective

(AL) Pr.4 Unit magnification (AM) 1:1 times 10:10 times 100:100 times 1 1 151 301 451 1000:1000 times (Note 1) LECSS sets [262144] Pr.1 Unit setting Set the unit used for defining positioning operations.

SV1000 3 position 73 (.16) (B) 2 (A) 4 4 position dual 3 port 71 (.15) SOL.b SOL.a Single solenoid 74 (.163) 3 (EB) 5 (EA) Double solenoid 78 (.17) SV2000 1 (P) 3 position 83 (.18) 4 position dual 3 port 78 (.17) 4 position dual 3 port valve: N.C./N.O.

8 3 7 1 6 4 1 5 500 Stroke (mm) 100 50 0.05 0.1 0.5 1 2 0.05 0.1 0.5 1 2 Load (kN) Load (kN) Bore size 32 Bore size 40 800 6 8 6 4 8 3 7 5 3 7 4 5 1 500 1 Stroke (mm) 100 50 0.05 0.1 0.5 1 2 3 0.1 0.05 0.5 1 2 5 Load (kN) Load (kN) 20 Series CHN Technical Data 3-1 Cylinder Cushion Selection Procedure Caution Use a cylinder cushion within the maximum absorbed energy range.

Starting the Product . 4-1 4.1 Before Starting . 4-1 4.2 Preparation for Start . 4-2 4.2.1 Power supply . 4-2 4.2.2 Option B Earth leakage breaker . 4-2 4.2.3 HRSH--20-B1 HRSH--20-S and HRSH--40. 4-3 4.2.4 Setting of circulating fluid temperature . 4-3 4.2.5 Setting of pump operation mode . 4-3 4.3 Preparation of Circulating Fluid Supply to Users Equipment . 4-4 4.4 Operation Start and Stop

) Variations R 1/ 4, NPT 1/4, G 1/ 4 (With M5 male thread) URJ 1/4, TSJ 1/ 4 Port size Leak rate 1 x 10 5 Pa. m 3/ s 1 x 10 10 Pam3/s 100 kPa 1MPa 100 kPa 1 MPa Rated pressure range 0 0 0 0 100 kPa 100 kPa 2 outputs NPN or PNP Output Switch output Output voltage 1 to 5 V Analog output 16-2-27 4 High Precision, Digital Pressure Switch For General Fluids Series ZSE50F/ISE50 How to Order ISE50

4 4 4 63.5 74.5 74.5 83 3 3.5 3.5 4 10 10 10 10 15 15 16 16.5 7 7 8 8.5 20 25 32 40 For long stroke, refer to page 9-2-32.