This is a legacy product. Please contact us for the latest version.sales@ocaire.com NEW SY5000 MFLD. NO SIZE RATING". VALVE. "NEW SY5000 MFLD. N lb. 2J.
6 Station Mfld,Plug-in Connecting Base, 4/5 PORT SOLENOID VALVE, O84, 614.00000 lb
8 Station Mfld,Plug-in Connecting Base, 4/5 PORT SOLENOID VALVE, O84, 703.6 lb
10 Station Mfld,Plug-in Connecting Base, 4/5 PORT SOLENOID VALVE, O84, 793.1 lb
4 Station Mfld,Plug-in Connecting Base, 4/5 PORT SOLENOID VALVE, O84, 524.5 lb
12 Station Mfld,Plug-in Connecting Base, 4/5 PORT SOLENOID VALVE, O84, 882.6 lb
COMBINATION MANIFOLD ASSEMBLY, 4/5 PORT SOLENOID VALVE, O84
Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: M (SI units only)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: M (SI units only)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)