SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-M-01-WY"

by the element 40 m (80 m) shall be 40 m (80 m) or more in depth x height x width.

A A1 E1 L1 MM RR1 U1 NZ L 42 56 16 20 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 42 56 14 18 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 I-G04 I-G05 Y-G04 Y-G05 36 41.6 +0.5 +0.3 +0.058 0 -0.3 -0.5 +0.058 0 44 50.6 +0.5 +0.3 +0.070 0 Knuckle pin and snap ring are included. -0.3 -0.5 +0.070 0 Knuckle Pin (Also used as double clevis pin) Rod End Nut d d Dd9 C m m l L t t H B Material: Carbon

end plate assembly Manifold block assembly U side end plate assembly < End plate assembly > AXT512 A AXT512 1A End plate position Cylinder port position Wiring specification L side R side L R L side R side L R Side Bottom A B P, R port size Rc1/2 Rc3/4 12 One-touch fitting 04 06 C12 Cylinder port size Rc3/8 Rc1/2 03 04 < Manifold block replacement parts> Part No

Symbol Name PA06 CMX Electronic gear numerator 1 0 to 65535 PA07 CDV Electronic gear denominator 1 1 to 65535 Set the values as follows. 1 [PA06] M = 1000 [PA07] Actuator lead (L) [mm] n1/n2 M : [Servo motor resolution : 262144(Pulse/rev)] n1/n2: Pulley ratio *1 EX.)

L/A LED Table 10-22 L/A LED L/A 1/2 SI 1/2XF1/2PROFINETEthernet SI 1/2XF1/2PROFINETEthernet SI 1/2XF1/2 SI 1/2XF1/2 * *: Link LED Act LED 10.9.1.5. FO1/2 LED Table 10-23 FO 1/2 LED FO 1/2 2dB 0dB 2dB 0dB 10.9.2. LED 2 LED UT1 UT2 UT1 UT2 IN0, IN1, , IN7 M IO (Zone M) / Z1,Z2,Z3 (Zone 1-3) / Fig. 10-4 EX245-FPS1/2/3 LED 2 10.9.2.1.

entry O-ring + Wiring top entry Digital pressure switch (Body only) 25 65 NPN output Output PNP output + Lead wire With unit conversion function Nil Note 2) M P Note 2) Unit Note 1) Fixed SI unit Pressure unit: psi (Initial value), with unit conversion function + Nil L Without lead wire Lead wire Lead wire with connector (2 m) + Nil Without accessories (Switch body only) Accessories With

Symbol Name PA06 CMX Electronic gear numerator 1 0 to 65535 PA07 CDV Electronic gear denominator 1 1 to 65535 Set the values as follows. 1 [PA06] M = 1000 [PA07] Actuator lead (L) [mm] n1/n2 M : [Servo motor resolution : 262144(Pulse/rev)] n1/n2: Pulley ratio *1 EX.)

_OUT2 6 N.C. 5 N.C. 4 White CH1_OUT2 3 Black C/Q (CH1_OUT1) 2 Blue L 1 Brown L+ 4 Black: 3 Blue: L C/Q (CH1_OUT1) 100 42.5 Front protection cover + Panel mount adapter 53 55 or more 47 37.5 +0.1 0.2 (2) 9.4 42.4 46.4 55 or more 4 x R1 or less Front protection cover Panel mount adapter Panel Waterproof seal m48 conversion adapter + Panel mount adapter (2) 6 1.5 48 Panel fitting dimensions

S 100 L Flow control valve (With pressure compensation) Enables constant movement even if there are load fluctuations.

N.O. 101.2 kPa to 0.2 VPA344 544 744 Pilot pressure (MPa) Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note) Same as operating pressure (Min. 0.2 MPa) 10 to 50C (No freezing. Refer to page 5-11-4.) Not required (Use turbine oil Class 1 lSO VG32, if lubricated.)

-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc 1/8 Pilot air port size RHC MK(2) Oil port size Rc RS Q G Throttle valve locking screw RS H A RZQ Oil port size Converter side Oil port size Cylinder side 2-S Wall mounting screw Unit port U1, U2 MI W S CEP1 CE1 CE2 (mm) Model Oil port size Rc A B CA CL GB GL KA KB KL L QA M NB NL QB QL R T GA 18

(A) 2 L: L style (VQ20 Only ) 1 1 (p) Note) Consult SMC if N.O. is desired. Note) If ordering both options, indicate "LF".

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nil Without cable Sensor cable (3 m) M5 Port size L M5 x 0.8 Option Sensor cable (3 m) + Connector (1 pc.) When only optional parts are required, order using the part numbers listed below.

LVN TI/ TIL PA PAX PB 0.8 MPa Po = 0.3 MPa Po=0.3 Mpa Initial pressure (Pressure at valve closing) Initial pressure (Pressure at valve closing) SGP piping length L (m) 17-3-59 8 The VX series will be revised shortly.

XLD-63 XLD-80 XLD-25 XLD-40 XLD-50 XLD-100 XLD-160 0.08 Nm 0.3 Nm 6-3.S S S S 6-4.M M M S 6-5./ S M S M 12 XL-OMY0002 7.

Ambient and fluid temperature M Symbol No grease is used.

bracket) are included with the above parts. 3 Direct Operated 2 Port for Heated Water Series VCB Dimensions Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical entry P Port

Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection PA14 0 1(+Counter motors side) Load to motor inertia moment ratio PB06 7 7 Function selection E-3 PE41 0 0 LEFS25(L,R)T6 LEFS32(L,R)T7 LEFS40(L,R)T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

/min (ANR)) Air flow rate (l /min (ANR)) AMH550 AMH250 B B 3 4 1 4 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) AMH650 AMH350 B 1B 3 8 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) 0.5 Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow

VQZ100 ( ( ( ( ) ) ) ) 90 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 DC L,M L,M L,M L,M > > > > > > DIN DIN DIN DIN > > > YSYOS (YZ) ( ( ( ( ) ) ) ) 90 [ 0.1Nm ] 8 No.VQZ100V-OMT0001 VQZ Series/ / / / > > > (YZ) ) 1V (+-) () (1mm) 3.23.7mm 3 3 3 3