SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-R-P-M5-JBK"

GD M Q R Bore size (mm) 20 25 32 40 M8 x 1.25 depth14 80 5.5 60 3.5 93 35 4 4 25 26 M5 x 0.8 54 50 14 105 M6 x 1 M10 x 1.5 depth18 95 9 70 4 103 40 7 7 32 31 M5 x 0.8 62 125 60 M8 x 1.25 14 M10 x 1.5 depth18 95 9 70 4 104 40 7 7 32 38 Rc 1/8 Rc 1/8 62 60 13 125 M8 x 1.25 M12 x 1.75 depth 21 115 11 82.5 4 115 45 8 8 38 47 67 75 14 150 M8 x 1.25 WH W X Y U W T V Z Bore size (mm) 20 25 32 40

kPa 100.0 to 100 kPa Symbol Calibration certificate Nil K p Piping specifications Option 2 M5 female thread/Side ported Piping port None Nil M5 Panel mount adapter + Front protective cover M5 female thread/Rear ported D Note 3) M5R Piping port R1/8/Side ported 01 DIN rail adapter Note 5) R1/8 Piping adapter R Note 4) NPT1/8/Side ported N01 Note 3) Not available for piping specifications

Action D Double acting Standard stroke (mm) Port thread type 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40, 50 Type M5 x 0.8 Rc1/8 NPT1/8 G1/8 Bore size 6, 10, 16, 20, 25 32 32 32 Symbol Nil TN TF Applicable Auto Switches/Refer to page P.68 to 72 for further information on auto switches.

)] 2 (12AWG) 1418mm4 () 3.5mm 0.6m 30m (1.3 ) M4 : 9.5mm R 1 M5 : 9.5mm M4 1.42.0Nm R M5 2.6Nm 2-9 IDF100150F-W 2.2 2 7 IDX-OM-Z004 2 2 (20AWG)17mm 6 0.5mm 0.9m 30m (1.3 ) M3 : 6.5mm M3 0.631Nm OFF 56 alternate ON ONOFF OFF IDF100150F-W 2.2 2 8 IDX-OM-Z004 2 2.3 2.2.1 1. 2. 2 3. 4. 5.

Symbol Bore size (mm) A A' B B' D E F GA GB H J MM NN R FC FT FX FY FZ 6 7 9 14 14 3 10.5 8 6 6 17 6 M3 x 0.5 7 3.4 1.6 24 16 32 M10 x 1.0 10 10 12 15 17 5 13 8 6 7 20 7 M4 x 0.7 8 4.5 1.6 28 18 37 M12 x 1.0 15 12 14 20 19 6 15.5 10 6 7 24 9 M5 x 0.8 10 5.5 2.3 36 22 49 M14 x 1.0 Symbol S Z With auto switch W Bore size (mm) 5 st 10 st 15 st 20 st 30 st 5 st 10 st 15 st 20 st 30 st FI P

Symbol Bore size (mm) A A' B B' D E F GA GB H J R MM FC NN FT FX FY FZ 6 7 9 14 14 3 10.5 8 6 6 17 6 7 M3 x 0.5 3.4 M10 x 1.0 1.6 24 16 32 10 10 12 15 17 5 13 8 6 7 20 7 8 M4 x 0.7 4.5 M12 x 1.0 1.6 28 18 37 15 12 14 20 19 6 15.5 10 6 7 24 9 10 M5 x 0.8 5.5 M14 x 1.0 2.3 36 22 49 Symbol S Z With auto switch W Bore size (mm) 5 st 10 st 15 st 20 st 30 st 5 st 10 st 15 st 20 st 30 st FI P

2 i r i t y w w e !0 !0 !2 !5 o !0 !4 q q y u !1 !3 r t !1 M5 type U10/32 type M5 type U10/32 type !1 y !2 u !4 !3 i !5 u e r r t w e o !0 i o q q t y !0 !2 w !

X 0.8Depth11 M6 X 1Depth11 AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT M5 X 0.8Depth7.5 M6 X 1Depth12 M8 X 1.25Depth13 M8 X 1.25Depth11 M10 X 1.5Depth15 M10 X 1.5Depth14.5 M12 X 1.75Depth18 M12 X 1.75Depth15 Rod end female thread (mm) (mm) P M5 X 0.8 Rc(PT)1 /8 Rc(PT)1/8 Rc(PT)1/4 Rc(PT)1/4 MM M6 X 1Depth12 NY 26 28 36 42 46 H 14 14 15 18 21 NX 6 6.5 8 10

OUT OUT 1 1 R1/8, NPT1/8 (With M5 female thread), Rc1/8, G1/8, M5 female thread 4, 6 one-touch fitting Piping OUT OUT 2 2 Features 1 2-Color Display High Precision Digital Pressure Switch How to Order Series ZSE40A(F)/ISE40A Rated pressure range ISE40A 14.5 to 145.0 psi ISE40A 01 X P For positive pressure For vacuum/ compound pressure ZSE40A 01 Y P Made to Order Specifications/Description

A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000

The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u.

When the IDF100F-30 is provided with options C, R and V and specified to have the facility water piping direction on the right side, the part number will be IDF100F-30-CRVW4. NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.

Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89

pressure ZSE50 02 M F L 22 For compound pressure Piping specifications Option 02 T2 G2 R 1/4 (M5 with female screw), Piping in backward direction Nil None NPT 1/4 (M5 with female screw), Piping in backward direction Bracket A G 1/4 (M5 with female screw), Piping in backward direction Optional A Input/output specifications 22 30 62 NPN open collector 2 output + Analog output Bracket D NPN

P Reduced setting efforts P Reduced chance of set-value input error Cop Copy Copy Master Unit 1 Slave Unit 2 Unit 10 3-step setting -step setting 3-step setting 1 2 3 Push Push Push Push Push Push Adjust to set-value with buttons. Finish setting Added vacuum range. P Rated pressure range: 0.0 to 101.0 kPa 0 101 kPa Expanded pressure range for positive-pressure type to the vacuum range.

Bore size (mm) 20 32 40 50 63 80 100 M5 x 0.8 M5 x 0.8 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M10 x 1.5 2 4 4 4 4 4 4 3 3 3 6 11.5 24 34 7. Do not use two cylinders facing one another horizontally or vertically in such a way that their piston rods strike each other. 8.

Miniature Fittings M3, R(PT) 1/8, M5 Series M Series M5 Manifold: M-5M Bulkhead reducer: M-5ER Panel mounting plate thickness max. 3.5mm For the plate thickness 3.5 to 6mm, give the plate tapping M12 0.75, and then screw-in. For the plate thickness 3.5 to 6mm, give the plate tapping M12 0.75, and then screw-in.

( )C-R ( ( ( ( ) ) ) ) DC 3% AC 20% (SSR (SSR (SSR (SSR )AC )AC )AC )AC 1) (C-R ) OFF 2)() 1V 5 VF1000-OMP0001 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 5 5 5 5 / / / / DC 1 1 ()ISO VG32 (MSDS) 2 ()ISO VG32 M5 M5 M5 M5 1/61/4 11.5Nm ) Rc Rc Rc Rc Nm Rc1/8 79 Rc1/4 1214 Rc3/8 2224 6 VF1000-OMP0001 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000

Vertical actuation I II P W A P a (b) (a) P P a A W (1) Basically adjusted with meter-out control. When meter-in control is also used, lurching is reduced. (1) Basically adjusted with meter-out control.

input No., State (P-No.) label C-AND OR input time out subroutine call command General-purpose input No., State (P-No.) label C-OR AND input condition jump command General-purpose input No., State (P-No.) label J-AND Condition jump OR input condition jump command General-purpose input No., State (P-No.) label J-OR Program Control Commands Parameter value Mnemonic Classification Function