SMC Corporation of America
Elite Part Number Search
Search Results "HRS090-AN-40-M"

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Cooling Capacity: 38 kW, Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, with Rc-NPT Conversion Fitting, Power Supply: 50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC, Option: Applicable to Deionized Water Piping

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Cooling Capacity: 250 (25 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)

Cooling Capacity: 300 (28 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

(C) Correction factor 1.25 1.11 1 0.90 0.63 2 to 25 30 32 35 40 2 to 25 30 32 35 40 45 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 Note) For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45C.

) L1 = 50 [mm] L2 = 40 [mm] m L2 L1 Item Load factor an Note 1.

MI W S 100 200 50 CEP1 130 50 100 50 40 40 CE1 40 Weight of transferred object m (kg) Weight of transferred object m (kg) 32 30 40 50 CE2 20 30 32 20 ML2B 20 16 10 C J G5-S 10 12 5 4 CV 3 4 5 3 MVGQ 2 2 CC 1 1 RB 1 5 10 20 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) J Lateral Load and Operating Pressure DThe larger the lateral load, the higher the operating pressure required

1 20 50 76 75 100 200 DStroke (mm) Stroke (mm) -X MGPL32 to 63 MGPL32 to 63 30 30 20Data 50, 63 20 20 50, 63 50, 63 32, 40 Load weight m (kg) Load weight m (kg) 50, 63 50, 63 32, 40 32, 40 32, 40 32, 40 50, 63 10 10 32, 40 5 20 25 25 26 26 50 76 75 100 200 5 20 50 76 75 100 200 Stroke (mm) Stroke (mm) MGPL80, 100 MGPL80, 100 50 50 40 40 100 100 30 30 80 Load weight m (kg) Load weight m (

m [kg] V = 50 1.5 V = 100 V = 150 1.0 V = 200 0.5 0.0 0 20 40 60 80 100 120 140 Allowable overhang L [mm] MXQ16(A)-10, 20, 30Z MXQ16(A)-40, 50Z 4.5 4.5 V = mm/s V = mm/s 4.0 4.0 3.5 3.5 Load mass m [kg] Load mass m [kg] V = 50 V = 50 3.0 3.0 V = 100 V = 100 2.5 2.5 V = 150 V = 150 2.0 2.0 1.5 1.5 V = 200 V = 200 1.0 1.0 0.5 0.5 0.0 0.0 0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 70 60 Allowable

Note) The -X126 model cannot be manufactured with an L plug connector for electrical entry. Therefore, use a grommet type or an M plug connector.

-25S/C 0.49 MHKL2-25S MHKL2-25C M: Allowable moment (M = WL) 100 100 W 80 80 Gripping force (N) Gripping force (N) M Pressure 0.6 MPa Pressure 0.6 MPa 60 60 Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 0.5 MPa 40 40 L 0.4 MPa 0.4 MPa 0.3 MPa 0.3 MPa 20 20 0 0 20 40 60 80 100 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) 12-6-11 11 Series MHK2 Dimensions MHK2-12: Standard type 9