SMC Corporation of America
Elite Part Number Search
Search Results "CDU6-5D-M9NV"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Clean Series: Vacuum Suction Type, Magnet: Built-in, Bore Size: 6mm, Stroke: 10mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Series: Vacuum Suction Type, Magnet: Built-in, Bore Size: 6mm, Stroke: 20mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Series: Relief Type, Magnet: Built-in, Bore Size: 6mm, Stroke: 30mm, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 5m, Number: -

Clean Series: Relief Type, Magnet: Built-in, Bore Size: 6mm, Stroke: 30mm, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -

Clean Series: Relief Type, Magnet: Built-in, Bore Size: 6mm, Stroke: 10mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, FREE MT, CLEAN ROOM, ACTUATOR, CU COMPACT CYLINDER, C5, 6MM CU CLEAN-ROOM, .08575 lb, ModelStroke (mm) 51015CDU60.170.150.13

The series CU free mount cylinder saves space and allows direct and precise mounting. It is available in 6mm to 32mm bore sizes with stroke lengths up to 50mm. Options include auto-switch capabilities, free mount choices, recessed switch mounting grooves, non-rotating rod, double rod, single and double acting, and rubber bumpers standard. Bore sizes from 6mm to 32mm available, Stroke lengths

DC AC 0.5 1 3 5 () (M) (L) (Z) M9NV M9N IC 3 NPN 5V 3 PNP M9PV M9P 12V 2 12V M9BV M9B M9NWV M9NV IC 3 PNP M9PWV M9PW 3 NPN 5V 12V 2 2 12V M9BWV M9BW 24V M9NAV M9NA IC 3 PNP M9PAV M9PA PLC 3 NPN 5V 12V 2 2 12V M9BAV M9BA 2 2 P3DW 3 NPN A96V A96 IC 12V 100V A93V A93 2 24V 5V 100V A90V A90 IC PLC 12V 0.5m D-M9N M 1m D-M9NM L 3m D-M9NL Z 5m D-M9NZ 1 17 - 7-2. -1516

Auto-Switch D-M9NV M9NWV Auto-Switch D-M9NWV A93V D-A93V M9PV D-M9PV M9PWV D-M9PWV A96V D-A96V M9BV D-M9BV M9BWV D-M9BWV M9NA D-M9NA M9PA D-M9PA M9BA D-M9BA M9NAV Waterproof D-M9NAV M9PAV Waterproof D-M9PAV M9BAV Waterproof D-M9BAV See separate catalog for the details of Auto-switch. 2-2-3 Options Multi Counter Extension Cable *1 Supply voltage Connector Nil w/o connector C R04-J8M7.3

A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV

D-M9NV M9NWV D-M9NWV 2-color Indication Solid State Auto-Switch A93V D-A93V M9PV D-M9PV M9PWV D-M9PWV A96V D-A96V M9BV D-M9BV M9BWV D-M9BWV A72 D-A72 F9G D-F9G F79W D-F79W Solid State Auto-Switch A73 D-A73 F9H D-F9H F7PW D-F7PW Reed Auto-Switch A80 D-A80 F79 D-F79 J79W D-J79W A72H D-A72H F7P D-F7P F7NWV D-F7NWV A73H D-A73H J79 D-J79 F7BWV D-F7BWV A76H D-A76H J79C D-J79C M9NA D-M9NA A80H

Load voltage Electrical entry Lead wire length (m) Flexible lead wire (-61) Auto switch model Applicable load Pre-wire connector In-line Perpendicular 0.5 (Nil) 3 (L) 5 (Z) DC AC Type Special function Electrical entry Indicator light Wiring (Output) 3-wire (NPN) 3-wire (PNP) 24 V 12 V Solid state switch M9NV M9N 5 V IC circuit M9PV M9P Relay, PLC Standard Grommet Yes 2-wire M9BV M9B