SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, RC, 80MM CQ2-Z OTHERS (COMBO), 5.42743 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, RC, 80MM CQ2-Z OTHERS (COMBO), 5.34620 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, RE, 80MM CQ2-Z DBL-ACT AUTO-SW, 5.29109 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 80MM CQ2-Z DBL-ACT AUTO-SW, ACTUATOR, CQ2-Z COMPACT CYLINDER, RE, 80MM CQ2-Z DBL-ACT AUTO-SW, 5.38064 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
V M9NA1 v v V v v IC circuit 3-wire (PNP) M9PA1 v v V v v 2-wire 12 V M9BA1 v v V v v 24 V Water resistant (2-color indicator) Grommet With diagnostic output (2-color indicator) 4-wire (NPN) 5 V, 12 V F59F V V v v IC circuit Magnetic field resistant (2-color indicator) 2-wire (Non-polar) P3DWA V V V v P4DW V V v Yes 3-wire (NPN equivalent) 5 V A96 V V IC circuit 100 V A93
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
NPN) F9NV F9N 3 wire(NPN) Diagnostic indication (2 color) F9PV F9P 3 wire(PNP) P.5.3-39 F9BV F9B 2 wire Relay, PLC 24V Yes Grommet 12V F9NWV F9NW 3 wire(NPN) F9PWV F9PW P.5.3-66 3 wire(PNP) F9BWV F9BW 2 wire PLC: Programmable Logic Controller *Lead wire length 0.5m (Ex.) 3m L A93 A93L Specifications Specifications are same as the standard style.
Note) When two D-A93/M9/M9W auto switches are used 1397 Series RSG Operating Range Auto switch model Bore size (mm) 40 50 D-A9 8 8 D-M9 D-M9W 4.5 5 D-C7/C80 D-C73C/C80C 10 10 D-H7/H7W D-H7BAL/H7NF 5 6 D-H7C 10 9.5 Since this is a guideline including hysteresis, not meant to be guaranteed.
D-A93 Less than 50 strokes MQ D-M9 D-M9W Less than 20 strokes Less than 55 strokes RHC RZQ D-X Individual -X 1211 Series RHC Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Reed auto switch Solid state auto switch D-A9 D-M9 D-M9W 20 to 40 20 to 40 ( ): For D-A93 type Hs Hs 8.5 16.5 16.5 8.5 B A B A 22 22 (24.5) Auto switch Auto switch 50 to 63 50
A93 3m. L A93L Note) Refer to P. 177 to 179 for further information of auto switch. PLC: Programmable Logic Controller Specifications Specifications are same as the standard type.
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked are produced upon receipt of order.
AC DC Auto switch model Lead wire length (m) Load voltage Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire Reed switch Solid state switch A96V A96 5 V IC circuit Grommet (NPN equivalent) Yes Yes Relay, PLC 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV
Rubber bumper Nil Built-in magnet No Auto switch D With auto switch (Built-in magnet) Solid state M9B, M9BW, K59, K59W Reed switch A93, B54 Clean series Bore size (mm) Auto switch mounting method is band mounting only.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
Applicable models: D-A73, A73H, A73C, Z73, D-A93