ZZ1 h 125 140 160 0.2 stroke 463 Up to 1000 133 0.2 stroke 503 Up to 1000 133 0.2 stroke 567.5 Up to 1200 141 9-8-12 13 Series CNS Cylinder with Lock Double Acting, Single Rod Foot style (L): CNSL Rc BQ plug with breathing hole BC element 2-MA Thread effective depth R 4-J CL GA H T GL GR GB AL A K F Rc BP Unlocking port 2-Rc P Cylinder port (For NPT port) G G FA MM Q CL D EA LY E CL1 V 4-LD
L2: 3000 mm 44 62 73 Station number 9 9 2-Rc 1/8 (External pilot port) Electrical entry on U side (LU) 15 12 X n Manual override 2 B 4 A 8 2 B 4 A B A B A B A B A B A A A 7 SMC SMC SMC SMC SMC SMC SMC B B B A A A A A A A Indicator light 2 B 4 A 6 2 B 4 A 5 L2 L1 2 B 4 A 4 B B 2 B 4 A 3 2 B 4 A 2 50.5 P = 25 P = 25 2 B 4 A 1 44 12 X Stations 38 26.5 D side R4.5 Electrical entry on D side (LD
LH Width across flats KA VA BN N N X X Y Y LT LX C B S + Stroke ZZ + Stroke LS + Stroke With rod boot 75 15 40 l h + l ZZ1 + l + Stroke Long strokes Rc(PT) BQ Plug with breathing hole 4-J CL 2-MA Effective thread depth R BC element AL FA A K H GA F GB Rc(PT) BP Unlocking port GR GL T G G 2-Rc(PT) P Cylinder port MM Q D EA RY E LY LH V 4-LD Width across flats KA VA BN S + Stroke N RT N X
B 2 A 4 6 B 2 A 4 SMC SMC SMC SMC SMC 5 Cable length B 2 A 4 4 L2 L1 B 2 A 4 3 B 2 A 4 2 P=41 34.5 48 P=41 B 2 A 4 1 58.5 68.5 X 12 Stations D side 42 16 15.5 22 107.8 51 179 117 69 Electrical entry on D side (LD) 2-1/8 (external pilot port) Dimensions Formulas: L1 = 41n + 76, L2 = 41n + 96 L n 9 445 465 8 404 424 L1 L2 7 363 383 6 322 342 5 281 301 4 240 260 3 199 219 2 158 178 1 117 137
B 2 A 4 6 B 2 A 4 SMC SMC SMC SMC SMC 5 Cable length B 2 A 4 4 L2 L1 B 2 A 4 3 B 2 A 4 2 P=41 34.5 48 P=41 B 2 A 4 1 58.5 68.5 X 12 Stations D side 42 16 15.5 22 107.8 51 179 117 69 Electrical entry on D side (LD) 2-1/8 (external pilot port) Dimensions Formulas: L1 = 41n + 76, L2 = 41n + 96 L n 9 445 465 8 404 424 L1 L2 7 363 383 6 322 342 5 281 301 4 240 260 3 199 219 2 158 178 1 117 137
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Type: Pneumatic, Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 10mm, +: +, Stroke 2: 15mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
LH CX MM N N 2 x 4 Width across flats KA 3.2 MQ S + Stroke Y X LZ LX Y X Z ZZ + Stroke LS + Stroke RHC (mm) RZQ A AL B B2 F G H H1 H2 I K KA D B1 C LD LH MM LS LX LZ N NA Bore (mm) 20 M8 x 1.25 18 20 15.5 30 40 26 13 10 55 41 8 13 40 186 40 5 8 33.5 5 6 6.8 25 25 M10 x 1.25 22 20 19.5 34.5 47 32 13 10 55 45 10 17 45.5 186 40 6 8 37.5 5.5 8 6.8 28 D32 M10 x 1.25 22 22 19.5 42.5 47 32 13 11
actuator Air gripper Directional control valve Fittings & Tubing Pressure switch Clean gas filter Flow control equipment Filter, Pressure control equipment Air preparation equipment HB HT HC X N A W K 2-Plug H HA CB 2-P (Piping port) Y HP Counter bore depth C 4-counter bore B T T 4-J x E 0 -0.1 L Cylinder tube outer circumference: TC Hard chrome plated + special treatment WP X F GW GP 4-LD