SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2L50-1000-D-A93S"

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1000mm, Option: Rear Cushion, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 1 pc., Lock

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 900mm, Option: Rear Cushion, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 1 pc., Lock Unit

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: Simple Joint A Type + Joint, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector

Fan motor Outlet thermometer Model Selection (Flow Capacity l/min (ANR)) HAA7 HAA15 HAA22 HAA37 Model Outlet side air (COOL AIR) 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000 Inlet air temperature 4300 Cooling side air Cooler Conditions: Outlet temperature 40C, Ambient temperature 32C, Air pressure 0.7 MPa Drain 14-15-1 2 Series HAA How to Order Precautions 15 10 D 1

2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMS0006CN-G * FG (35 N () ,() *() 6 33 () () 30m DC(-)() * -6No.PS-OMS0006CN-G ( ) () CE/UKCA -5~50(5 ) * , 1015 10 1% 2053 LCD * -7No.PS-OMS0006CN-G N M5 ISE20 3 ISE20 -0.1001.000 MPa Y ZSE20 0.0-101.0 kPa K ZSE20F -100.0100.0 kPa T 2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D

Printed in Japan. 1st printing September, 1999 D-SMC.L.A. P-80 (D)

Static Neutralization Characteristics (Discharge Time from 1000 V to 100 V) (1) Energy saving static neutralization nozzle/IZN10-01 (2) High flow rate nozzle/IZN10-02 5 5 0.1 MPa 0.05 MPa 4 4 0.3 MPa 0.05 MPa Discharge time [s] Discharge time [s] 3 3 0.1 MPa 2 2 0.7 MPa 0.3 MPa 1 1 0.5 MPa 0.5 MPa 0.7 MPa 0 0 200 400 0 0 400 200 Distance [mm] Distance [mm] (3) Female threads for piping/IZN10

consumption (W) Max. operating frequency (Hz) A 80 1200 B 40 1000 C 10 550 D 4 350 E Note) Two mounting screws (M3 x 0.5) and a gasket are included.

(In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1. Consult SMC concerning water resistance, flexibility of lead wires, and usage at welding sites, etc. 98

D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73 D-A80 D-A79W Bore B A B A B A B A B A 32 8 (6) 7 (5) 8.5 (6.5) 14.5 (11.5) 9 (7) 8 (6) 7 (5) 6 (4) 6 (5) 12 (9) 40 10 (11) 12 (9) 7.5

of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL

U side D side D D D D D D 3 2 1 Stations How to Order Solenoid Valve 10 SV 1 1 0 0 F 5 Note) Clean series Note) Available with manifold block for station additions. Refer to the WEB catalog.

D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30

-1 S Series Introduction .D-27 How To Order.D-28 90.D-29 Repair Kits .D-33 Seal Options .D-33 PS Series Introduction .D-4 How To Order.D-5 In-Line.D-6 90.D-15 Repair Kits .D-26 Seal Options .D-26 D Swivels Quick Coupling Division 8145 Lewis Road Minneapolis, MN 55427 www.parker.com/quickcouplings D-3 Introduction PS Series Swivels Introduction Features The design and manufacturing processes