SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2RA16-60Z-M9BV-B"

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead

1 Chrome molybdenum steel Hexagon socket head bolt Chrome molybdenum steel Hexagon socket head bolt Rare earth magnet Magnet B !

1 Chrome molybdenum steel Hexagon socket head bolt Chrome molybdenum steel Hexagon socket head bolt Rare earth magnet Magnet B !

B 0.2 A 0.2 Bore size A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 8.

Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B B A W A B stroke 6 5 to 30 3.5 0 17 6.5 13 3.5 2.5(5) 17 4.5 5 to 20 17 13 17 10 25 7.5 3.5 20 16 2.5 7.5 20 1.5 0.5 30 19 15 19 (1) 5 27 23 27 10 22 18 22 15 27 23 27 16 8 4 2 8 2 0 B A 20 22 18 22 Bore (mm) 6 10 16 25 27 23 27 (0.5) 6.9 10 30 27 23 27 8.8 14 13.9 19 Note 1) Negative figures

Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B A B B W A stroke 6 5 to 30 0 13 3.5 3.5 6.5 17 2.5(5) 17 4.5 5 to 20 13 17 17 10 25 3.5 16 7.5 7.5 2.5 20 1.5 20 0.5 30 15 19 (1) 19 5 23 27 27 10 18 22 22 15 23 27 27 16 4 8 8 2 2 0 A B 20 18 22 22 Bore (mm) 6 10 16 25 23 27 27 (0.5) 10 6.9 30 23 27 27 14 8.8 19 13.9 Note 1) Negative figures

W B D-A9, D-A9V D-M9, D-F9W D-M9V, D-F9WV Bore size (mm) B A W A B W A 10 16 20 25 32 0.5 7.5 2.5 7.5 16.5 3 12.5 16.5 1.5 (1) 0 8 1.5 8 20 4 16 20 2 (0.5) 2 10 0 10 24 6 20 24 4 (1.5) 3.5 11.5 1.5 11.5 26.5 7 22.5 26.5 5.5 (3) 4.5 12.5 2.5 12.5 27.5 8 23.5 27.5 6.5 (4) Note 1) Figures in the table above are used as a reference when mounting the auto switches for stroke end detection.

Replacement Actuator (Cylinder) CY1F R B 10 Stroke Note) -XB10 or -XB11 is not required at the end of the part number for intermediate or long strokes.

W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/

B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.