SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2D16-175Z-M9P-A"

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 30mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 200mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead

Heater: 8 XLC Series Dimensions XLC: Air operated (b) E C Size 16, 25, 40 E C E Fn (KF flange) (a) D Auto switch (Option) Heater (Option) (c) H J B A G A (b) C E Size 50, 63, 80 E C E Fn (KF flange) Fd (K flange) (a) D Heater (Option) Auto switch (Option) (c) H J K B A G A [mm] Model A B C D E*1 Fn Fd G H J K XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121 48 27 12 40 26 44 21 XLC-

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,

Seal guide B Slide plate Spacer Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !

Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.2207 lb. 359.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, LL, 32MM CG NON-ROT AUTO-SW, 1.57262 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 13.88912 lb

If necessary, you can also combine the basic MY1 cylinder with an external guide in order to create a special engineered solution. Piping options can be selected according to the application. MY1 is available in 9 bore sizes from 16mm to 100mm.

MA a A MA a Cushion adjustment screw Air release R (max.)

Auto switch mounting Auto switch model C85 Series C75 Series Bore size [mm] 8 10 12 16 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V)*7 BJ6-008 (A set of a, b, c, d) BJ6-010 (A set of a, b, c, d) BJ6-012 (A set of a, b, c, d) BJ6-016 (A set of a, b, c, d) BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9lA(V) BJ6-008S (A

Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.

Even if a proper plier (tool for installing a type C retaining ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a retaining ring may be flown out of the tip of a plier (tool for installing a type C retaining ring). Be cautious with the popping of a retaining ring.

Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if a surge is applied repeatedly. When directly driving a load which generates a surge, such as a relay or solenoid valve, use a switch with a built-in surge absorbing element. 7.